Weber 55024 manual Reinstall control panel after checking for gas leaks

Page 16

Check:

1)Hose to manifold connection

2)Manifold to side burner hose connection

WARNING: If there is a leak at connection(1),

retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

3)Side burner hose to side burner connection

4)Valves to manifold connections

5)Hose to quick disconnect connection

WARNING: If there is a leak at

connections(2),(3),(4) or(5), turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(1)

(2)

(3)

(4)

(5)

Reinstall control panel (after checking for gas leaks)

(1)Set the control panel in place over both sides of the frame. Hold the crossover ignition button up while setting the control panel in place.

(2)Line up the control panel with the white plastic plugs in the frame brace. Insert screws and tighten with a Phillips screwdriver until snug. Do not overtighten.

(3)Push each of the burner control knobs onto their valve.

(4) Reinstall Side Burner cover.

C-4

Image 16
Contents Genesis GOLD-C Liquid Propane GAS Units only Warranty Customer Service Center South Hicks Road Palatine, ILContents Operating Gas Supply Testing For Installation in CanadaStorage Genesis Gold-C NG Manifold, Hose and regulator assembled Page Remove Packaging from Grill Remove Grill from Lower PackagingPage Assembly Instructions Install the slide out bottom trayInstalling the Warm-Up Basket Installing the warming rackInstall the bottom shelf Install the condiment basketInstall Side Burner Assembly Install Left Work SurfaceCheck that all burner valves are off Install Gas Supply General Specifications for Piping Gas Line Piping Test ConnectionsRemove the control panel Check for gas leaksReinstall control panel after checking for gas leaks Lighting To ExtinguishManual Lighting Lighting the Side Burner Lighting only the side burnerCooking CleaningStorage Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsMain Burner Cleaning Procedure General MaintenanceWeber Spider Stopper Guards Replacing Main Burners Crossover Ignition System Operations Flame is low when burner is on Burners burn with a yellow orOrange flame, in conjunction with Smell of gasSide Burner does not light Flame is low in High positionFlame is very yellow Conjunction with the smell of gas