Weber Genesis Gold C manual Check, Reinstall control panel after checking for gas leaks

Page 17

WARNING: Do not ignite burners when leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.

Check:

1) Hose to manifold connection.

WARNING: If there is a leak at connection (1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

2)Regulator to cylinder connection.

3)Manifold to side burner hose connection.

4)Side burner hose to side burner connection.

5)Valves to manifold connections.

6)Hose to regulator connection.

WARNING: If there is a leak at connections (2,3,4,5 or 6), turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual. When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(1)

(2)

 

(3)

(4)

(5)

(6)

Reinstall control panel (after checking for gas leaks)

(1)Set the control panel in place over both sides of the frame. Hold the crossover ignition button up while setting the control panel in place.

(2)Line up the control panel with the white plastic plugs in the frame brace. Insert screws and tighten with a Phillips screwdriver until snug. Do not overtighten.

(3)Push each of the burner control knobs onto their valve.

C-5

Image 17
Contents Owners Guide Liquid Propane GAS Units only Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyContents Operating For Installation in CanadaStorage Genesis Gold-C LP 04/18/01 Manifold, Hose and regulator assembled Page Remove Grill from Lower Packaging Remove Packaging from GrillPage Install the slide out bottom tray Assembly InstructionsInstalling the warming rack Installing the Warm-Up BasketInstall the bottom shelf Install the condiment basketCheck that all burner valves are off Install Left Work SurfaceInstall Side Burner Assembly Fill liquid propane cylinder Important LP Cylinder InformationPage Remove the control panel Check for gas leaksCheck Reinstall control panel after checking for gas leaksTo Extinguish LightingManual Lighting Lighting only the side burner Lighting the Side BurnerStorage and/or Nonuse CleaningCooking Removal of the LP cylinder Refilling the Liquid Propane CylinderLiquid Propane Cylinder To Connect the hose to the cylinderFor Canada Only Safe handling tips for Liquid Propane Gas CylindersLiquid Propane LP Cylinders Liquid Propane Cylinder requirementsInspection and cleaning of the Spider/Insect screens Annual MaintenanceMain Burner Cleaning Procedure General MaintenanceWeber Spider /Insect screens Main Burner Flame PatternReplacing Main Burners Crossover Ignition System Operations Flame is low when burner is on Barbecue temperature onlyBurners burn with a yellow or Orange flame, in conjunction withFlame is low in High position Side Burner does not lightFlame is very yellow Conjunction with the smell of gasWeber Spider Stopper Guards See Section B Install manifold bracketSee Section a See Section D