Weber 500 Series Refilling the LP tank, Connecting the filled LP tank, Removal of the LP tank

Page 24

Refilling the LP tank

We recommend that you refill before the scale indicator reaches "E".

Note - If you run out of fuel, check the indicator setting and/or adjust the fuel scale indicator setting with the scale setting wing nut, while the tank is empty so you do not run out again.

Removal of the LP tank

1)Close tank valve (turn clockwise). Figure 3 (a).

2)Slide the collar back on the quick disconnect to disengage the fitting. Figure 3 (b).

3)Loosen tank lock wing nut and turn tank lock up out of the way.

4)Lift tank off.

To refill take LP tank and tank filler adapter to a "Gas Propane" dealer.

mWARNING: We recommend that your LP tank be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight. IMPROPER FILLING IS DANGEROUS.

mWARNING: If you exchange your LP tank, make sure you get a similar tank in return. Your LP tank is equipped with a quick-disconnect valve and an OPD (Overfilling Prevention Device). Other LP tanks are not compatible with your barbecue connection.

Scale setting wing nut

Tank lock

wing nut

(a)

Tank valve

Collar

(b)

Connecting the filled LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

You will need: LP tank, a soap and water solution and a rag or brush to apply it.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks

a)Lift and hook the tank onto the fuel scale.

b)Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 4.

Figure 4

Figure 3

24

Image 24
Contents Spirit 500 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents For Installation in Canada General InstructionsStorage Operating areaAssembly Check package contentsStep REB Check contents of hardware packs Assemble wheel frame Assemble top frameContinue frame assembly Install tubing plugsAdd front panel Add cooking box Install manifold bracket Install tank panel assembly and frame connectorAdd fuel scale assembly Install igniterMCAUTION Do not remove adjustment wing nut from tank scale Set LP fuel scaleFill LP tank Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom traySlide the bottom tray onto the mounting rails under Cooking box with finger grip toward you. FigureInstall Lid Add tool holders, control panel and burner control knobsComplete accessory installation Lighting To ExtinguishManual Lighting Periodic Cleaning CookingStorage and/or Nonuse Storage and/or NonuseConnecting the filled LP tank Refilling the LP tankRemoval of the LP tank Engaged Safe handling tips for LP Gas Liquid Propane LP TanksAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsMWARNING Do not ignite burners while leak checking General Maintenance Main Burner Cleaning ProcedureMCAUTION Do not enlarge the burner ports when cleaning Weber Spider Stopper GuardsTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations When burner is on HIGH. Flames do not run Burner does not light, or flame is low in High positionMCAUTION Do not line the bottom tray with aluminum foil Burner flame pattern is erratic. Flame is low14-15 Parts List Page Page Final Word Thanks
Related manuals
Manual 32 pages 51.04 Kb