OPERATING INSTRUCTIONS

19

 

 

MANUALLY LIGHTING THE SMOKER BURNER

1

 

 

D6

 

 

 

 

WARNING: Check hose before each use of grill for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the grill. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www. weber.com®.

1)Open the lid.

DANGER

Failure to open the lid while igniting the grill, or not waiting 5 minutes to allow the gas to clear if the grill does not light, may result in an explosive flare-up which can cause serious bodily injury or death.

2,3,109

8

4

4

6,7

5

2)Open smoker box lid

3)Fill smoker with water soaked wood chunks or chips.

4)Make sure all burner control knobs are turned OFF. (Push control knob down and turn clockwise to ensure that it is in the OFF position.)

WARNING: The burner control knobs must be in the OFF position before turning on the liquid propane cylinder tank valve. If they are not in the OFF position, when you turn on the LP cylinder valve, the "excess gas flow control" feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP cylinder valve and burner control knobs. Then start over.

DANGER:

When the "excess gas flow control" feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the grill. Failure to do so may result in an explosive flare-up, which can cause serious bodily injury or death.

D4

1

6,7

2,3,10

9

8

4

5

*The grill illustrated may have slight differences than the model purchased.

5)Turn the cylinder on by turning the cylinder valve counterclockwise.

6)Put a match in the match holder and strike the match.

7)Insert match holder and lit match down through cooking grates and Flavorizer® bars to ignite smoker burner.

WARNING: Do not lean over the open grill while lighting.

8)Push smoker burner control knob down and turn to START / HI.

9)Check that the burner is lit by looking down through the cooking grate.

DANGER:

If the smoker burner does not light, turn the burner control knob to OFF and wait 5 minutes to let the gas clear before you try again.

10)Close smoker cover after wood starts to smolder and turn control knob to low.

TO EXTINGUISH

Push down and turn each burner control knob clockwise to OFF position. Turn gas supply OFF at the source.

4

Image 19
Contents BUILT-IN LP GAS Grill Owners Guide Summit #Liquid Propane GAS Units only Operating WARRANTY3Warranty Storage AND/OR NonuseGeneral Instructions Grilling Methods CleaningLeak Check Preparation Connecting the Liquid Propane CylinderGAS Instructions Fill Liquid Propane CylinderTo Connect the hose to the cylinder Part required Phillips Screwdriver Remove Control PanelCheck for GAS Leaks Check Reinstall Control Panel Safe Handling Tips for Liquid Propane GAS Cylinders Liquid Propane CylinderRefilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankCanada Liquid Propane Cylinder requirements Liquid Propane LP CylindersFlavorizer system Operating InstructionsGrilling Methods Direct CookingGrilling Tips & Helpful Hints Indirect CookingTo Extinguish LightingCrossover Ignition System Manual Lighting Operating InstructionsCleaning the smoker Using the SmokerTo use the smoker Lighting the Smoker Burner 109 Manually Lighting the Smoker BurnerInsert the rotisserie shaft in the motor Rotisserie AssemblyInstall the motor bracket Put the spit forks on the rotisserie shaftImportant Safeguards Using the RotisserieCooking Lighting the Rotisserie Burner Manually Lighting the Rotisserie Burner Operating Instructions Problem Check Cure Main & Smoker Burner TroubleshootingRotisserie Troubleshooting Weber Spider /INSECT Screens MAINTENANCE27Main Burner Cleaning Procedure Inspection and cleaning of the Spider/Insect screensReplace Main Burners 28MAINTENANCEMAINTENANCE29 BB 30MAINTENANCECrossover Ignition System Operations MAINTENANCE31Replace Igniter Batteries WEBER-STEPHEN Products CO