Weber 400 manual Manual Lighting

Page 7

MANUAL LIGHTING

EACH HEAT ZONE OPERATES INDEPENDENTLY.

High Medium

Low

Off

mDANGER

Failure to open sliding work surfaces while igniting the barbecue, or not waiting 5 minutes to allow the gas to clear if the barbecue does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

1)Open the sliding work surfaces and splash guards. Figure 2.

2)Check that fuel scale reads more than “E”. Note - E = empty; F = full.

3)Make sure all burner control knobs are turned OFF. (Push each burner control knob down and turn clockwise.)

mWARNING: The burner control knobs must be in the

OFF position before turning on the LP tank valve. If they are not in the OFF position, when you turn on the LP tank valve, the excess flow control will activate, limiting the flow of gas from the LP tank. If this should occur, turn OFF the LP tank valve and burner control knobs and start over.

Manual Lighting

1

4

3

2

Figure 2

mDANGER

When the excess flow control is activated, a small amount of gas is still flowing to the burners. After turning OFF the tank and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame- up which can cause serious bodily injury or death.

4)Turn on gas supply.

5)Select Heat Zone.

6)Put a match in the match holder and strike the match.

7)Push LEFT burner control knob down and turn to H (high).

mWARNING: Do not lean over open barbecue. Keep your face and body at least one foot away from the matchlight hole when lighting the barbecue.

8)Insert match holder and lit match through matchlight hole to ignite LEFT burner. Figure 3.

matchlight hole in control panel

Hole in cooking box assembly

Control panel

Left burner tube

Figure 3

9)Observe if LEFT burner has ignited by looking through matchlight hole.

mWARNING: If LEFT burner fails to ignite turn LEFT burner control knob to OFF and wait 5 minutes before attempting to ignite again.

10)After the LEFT burner is lit you can turn on the RIGHT burner.

Note: Always light the LEFT burner first. The RIGHT burner ignites from the LEFT burner.

TO EXTINGUISH

Turn gas supply OFF at the source, then push down and turn each burner control knob clockwise to OFF.

7

Image 7
Contents Summittm LP GAS Units only Table of Contents Word of Thanks WarrantyStorage For Installation in CanadaStandards and Codes Information Operating areaTo Extinguish LightingManual Lighting Cooking CleaningStorage Inspection and cleaning Spider/Insect screens MaintenanceSpider/Insect screens Main Burner Flame Pattern Main Burner Cleaning ProcedureReplacing the Burners Pull the manifold out of the burners. Figure Crossover Ignition System Operations Problem Check Cure TroubleshootingPage Page Patents & Trademarks