Weber 42370 dimensions BUILT-IN Cutout Dimensions, General Construction Details

Page 2

2

BUILT-IN CUTOUT DIMENSIONS

 

 

GENERAL CONSTRUCTION DETAILS

Summit® Built-In unit and all other accessory units should be on site before construction begins. All dimensions have a tolerance of plus or minus (+/-) 1/4 inch.The grill frame rests directly on the Island Structure top fi nished surface. Make sure this surface is level. Do not support the grill from the bottom. If the supporting structure is going to have an electrical outlet for a rotisserie, it should be on the left side of the structure.

24"

min.

24"

Access for electric

min.

on left hand side

 

24"

min.

4B

341/4"

3 3/ " 10 1/2"

21"4 min.

Side Burner

Opening

6 1/4"

Gas Inlet

301/4"

Built-In Frame

6 1/4"

27 inches min. distance from front edge of the cutout for open lid clearance

3 3/4"

Gas Inlet

Note: For a countertop treatment:

Recommended 3/4 inch overhang.

Notch front edge for frame to fully slide in.

*Clearance from any surface or structure is at least 24 inches from the back and sides of the grill.

24"

min.

24"

Access for electric

min.

 

on left hand side

2 4 " m in .

6B

341/4"

2 1 "

3 3/4"

10 1/2"

min.

Side Burner

Opening

6 1/4"

Gas Inlet

38 1/4"

Built-In

Frame

6 1/4"

27 inches min. distance from front edge of the cutout for open lid clearance

3 3/4"

Gas Inlet

Note: For a countertop treatment:

Recommended 3/4 inch overhang.

Notch front edge for frame to fully slide in.

*Clearance from any surface or structure is at least 24 inches from the back and sides of the grill.

Image 2
Contents Clearance from Surfaces or Structures BUILT-IN NG GAS Grill Installation GuideLocating Your Grill BUILT-IN Cutout Dimensions General Construction DetailsParts List Parts List Exploded View Platinum D4 Exploded View List Platinum D4 Exploded View Platinum D6 Exploded View List Platinum D6 Assembly Assembly Assembly Structure ASSEMBLY13 14ASSEMBLY Match Holder 16ASSEMBLY ASSEMBLY17 GAS Supply Typical Natural GAS Supply InstallationGeneral Specifications for Piping BUILT-IN GAS Line LocationsConnect GAS Supply GAS Line PipingTest Connections Ventilation WEBER-STEPHEN Products CO