Weber 42097 manual Gas Instructions, General Specifications for Piping, C407NG.c Gas Line Piping

Page 27

Gas Instructions

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must confirm to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL. Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifications.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to rigid, permanent construction.

￿WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

Gas supply

Inside wall

Outside wall

Shut off

This is a typical installation of a Weber® natural gas barbecue. Local codes may require different installations.

Locking shut off

Quick

 

3/ " Pipe

1/ " Pipe

disconnect

8

2

 

nipple

nipple

 

 

 

 

 

 

 

 

Do Not Use

C407_NG.c

Gas Line Piping

If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet.

Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or wrought iron pipe.

Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfide per 100 cubic feet of gas.

Plastic tubing is suitable only for outdoor, underground use.

Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.

Underground piping must have a minimum of 18" cover

Test Connections

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1

￿DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

Check that all burner valves are off

Valves are shipped in the OFF position, but you should check to be sure that they are turned OFF. Check by pushing down and turning clockwise. If they do not turn, they are off. Proceed to the next step. If they do turn continue turning them clockwise until they stop, then they are off. Proceed to the next step.

C-1

Image 27
Contents Natural Gas Grill Owners Guide M M I TLiquid Propane GAS Units only Contents Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyGeneral Instructions For Installation in CanadaGrilling Methods CleaningExploded View Exploded View List Parts List Parts List Ba402NG.a Only start these bolts Do not tighten yet Page Page Remove packing tape holding Page Page Matchlight Holder Page Page B407NG.c Page Page Page Page Page Test Connections General Specifications for PipingGas Instructions C407NG.c Gas Line PipingConnect Gas Supply Gas InstructionsCompletely remove the control panel 4 from the cooking Check for gas leaks Reinstall control panel Grilling Methods Operating Instructions Grilling Tips & Helpful HintsIndirect cooking To Extinguish LightingMinutes to let the gas clear before you try again or Manual LightingTo Extinguish Left burner control knob to OFF and waitLighting only the side burner Side Burner Lighting InstructionsTo use the smoker Using the SmokerLighting the Smoker Burner Manually Lighting the Smoker Burner Grill illustrated may have slight differences thanModel purchased Problem Check Cure Main & Smoker Burner TroubleshootingPush button ignition does not work Side Burner TroubleshootingWeber Spider /Insect screens MaintenanceAnnual Maintenance Main Burner Cleaning ProcedureReplacing Main Burners Positioned properly over Replace Igniter Batteries Crossover Ignition System Operations