Trane GEV, GEH Dimensions/Weights, 60 HZ 50 HZ, Shipping Weight With pallet, Economizer Weight

Page 7

Dimensions/Weights

Table 1: Unit weights

GEH

GEH

60 HZ

50 HZ

006-015 006-012

018-030 015-024

036-042

030-036

048-060

042-060

072-

090072

120090

150120

180150

GEV 60 HZ

006-015

018-030, 040

036, 042 048, 060

072

090

120

150

180

240

300

GEV

50 HZ

006-012

015-024 030, 036 042-060

-

072

090

120

150

180

240

Shipping Weight

with pallet

188 lb (85 kg)

278 lb (125 kg)

318 lb (143 kg)

428 lb (193 kg)

701 lb (318 kg)

714 lb (325 kg)

831 lb (377 kg)

907 lb (412 kg)

999 lb (454 kg)

178 lb (80 kg)

268 lb (121 kg)

308 lb (139 kg)

396 lb (178 kg)

617 lb (280 kg)

648 (294 kg)

861 (391 kg)

1215 lb (547 kg)

1225 lb (551 kg)

1615 lb (727 kg)

1665 lb (749 kg)

Shipping Weight w/o pallet

158 lb (71 kg)

248 lb (112 kg)

288 lb (130 kg)

398 lb (179 kg)

652 lb (296 kg)

666 lb (303 kg)

789 lb (359 kg)

865 lb (393 kg)

957 lb (435 kg)

158 lb (71 kg)

248 lb (112 kg)

288 lb (130 kg)

248 lb (112 kg)

Operating Weight

577 (262 kg)

608 (276 kg)

821 (373 kg)

1170 lb (527 kg)

1180 lb (531 kg)

1580 lb (711 kg)

1640 lb (738 kg)

WARNING Improper Unit Lift!

Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in death or serious injury or possible equipment or property-only damage.

Table 2: Waterside economizer weight

GEV

60 HZ

072

090

120 150, 180 240 300

GEV 50 HZ

-

072

090

120, 150

180

240

Economizer

Weight

148 lb (67 kg)

168 lb (76 kg)

207 lb (94 kg)

275 lb (125 kg)

310 lb (141 kg)

395 lb (179 kg)

GEH 60 HZ

006-015

018-030

036-042

048-060

GEH 50 HZ

006-012

015-024

030-036

042-060

Economizer

Weight

54 lb (24.5 kg)

65 lb (29.5 kg)

76 lb (35 kg)

97 lb (44 kg)

GEH

60 HZ

072

090

120

150

180

GEH 50 HZ

-

072

090

120

150

Economizer

Weight

138 lb (63 kg)

144 lb (65 kg)

166 lb (75 kg)

213 lb (97 kg)

213 lb (97 kg)

Weight Distribution for Hanging the GEH Model

Approximate weight distribution for proper hanging of the GEH unit is indicated by the diagram to the right.

Tolerance on the weights deter-

mined are ± 15%.

1/2 through 5-ton

6 through 15-ton

Total weights for each unit size are listed above.

WSHP-SVX01D-EN

7

Image 7
Contents Later Design Sequence Installation Owner DiagnosticsAmerican Standard Inc. All rights reserved Contents Fiberglass Wool Pre-installation ChecklistGeneral Information Option Supplemental or Boilerless Electric Heat Option Boilerless Control/Electric HeatOption Hot Gas Reheat 60 HZ 50 HZ Dimensions/WeightsShipping Weight With pallet Economizer WeightDimensions/Weights Clearance GEV 6 through 10 Ton Clearance Dimensions Figure GEV 1/2 through 5 Ton Clearance Dimensions FigureNpti Dimensions/Weights Left Return/Left SupplyDimensions/Weights Left Return/Back Supply Dimensions/Weights Left Return/Right Supply Dimensions/Weights Right Return/Left Supply Dimensions/Weights Right Return/Back Supply Dimensions/Weights Right Return/Right Supply GEV Npti FPT Dimensions/Weights Left Return/Top SupplyDimensions/Weights Left Return/Back Supply Dimensions/Weights Right Return/Top Supply Dimensions/Weights Right Return/Back Supply GEH 072-120 60 Hz GEH 072-090 50 Hz Dimensional Data GEH-Right Return/Left SupplyDimensional Data GEH-Right Return/Back Supply Dimensional Data GEH-Left Return/Right Supply Dimensional Data GEH-Left Return/Back Supply GEH 150-180 60 Hz GEH 120-150 50 Hz Dimensional Data GEH-Right Return/Back Supply GEH 150-180 60 Hz GEH 120-150 60 Hz Dimensional Data GEH-Left Return/Back Supply Dimensions/Weights Front Return/Back Supply Dimensions/Weights Front Return/Top Supply Dimensions/Weights Back Return/Front Supply Dimensions/Weights Back Return/Top Supply 12 1/2 and 15 Ton 60 HZ 12 1/2 Ton 50 HZ Dimensions/Weights Back Return/Front Supply Dimensions/Weights Front Return/Top Supply Dimensions/Weights Back Return/Top Supply 25 Ton 60 HZ 20 Ton 50 HZ 60 HZ 50 HZ Dimensions/Weights Front Return/Top Supply Dimensions/Weights Back Return/Top Supply Unit Filter Size Dimensions/Weights Waterside EconomizerUnit Hanging Shipping Hanging UnitDimensional Data Waterside Economizer Dimensional Data Waterside Economizer Dimensional Data Waterside Economizer Dimensional Data Waterside Economizer Unit Size 1/2 Ton 102 10 Ton 111 GEV 12 1/2 through 25 Ton Filter Installation InstallationGeneral Installation Checks Low Voltage Wiring AC & DC RequirementsReturn-Air Ductwork Supply-Air DuctworkReturn-Air Duct Panel Hanging the Horizontal Unit Sound Attenuation PadInstallation Types of Hose Connections Cleaning and Flushing Water LoopInstallation for Single Compressor Units Connecting a Water Regulating ValveInstallation for Multiple Compressor Units Field Installed Power Wiring Installation Power WiringControl Power Transformer Controls Using 24 VAC Installation Low Voltage WiringThermostat Location Mode Deluxe Board DiagnosticsColor Green Color Red ControllerInstallation Air Flow Adjustment Through 25 ton units only Air Flow AdjustmentVerify Installation Waterside EconomizerInstallation Waterside Economizer Unit Cabinet to the unit compressor compartment center post Start-up Sequence Waterside Economizing Three-Way Valve Specifications E1-Electrical performance Electrical RequirementsOvercur Heat Ampacity E2-Electrical performanceModel No 024 030 036 GEV Volts Total Fan Motor Num Minimum Maximum ElectricE3-Electrical performance Model No GEH GEV Volts E4-Electrical performanceProtective Device Model No GEV GEH Volts E5-Electrical performanceOvercur Heat Num Ampacity Rent Amps Protective Device E6-Electrical performanceModel No GEH GEV Volts Total Fan Minimum Maximum ElectricE8-Electrical minimum and maximum E7-Electrical performancePre-Start-up Checklist Pre-Start ChecklistInitial Unit Start-up Sequence OperationOperating Pressures Operation Pressures036 60 HZ 030 50 HZ 040 60 HZ Entering Water Temp Flow 018 60 HZ024 60 HZ 030 60 HZOperating Data Cooling 042 60 HZ048 60 HZ 060 60 HZDischarge Water Air Temp Sure Model Entering GEH/GEV Water Temp 072 60 HZ 090 60 HZ120 60 HZ Water FlowCooling Discharge Water Air Temp Model EnteringPressure Water VolumeWater Pressure Drop Unit Size 60 HZ 50 HZJob Name Model Number Date Serial Number Start-up Checklist LogPreventive Maintenance MaintenanceCondensate Trap Warranty Information Standard Warranty Warranty InformationHazardous Service Procedures Troubleshooting ChecklistDeluxe Controls Color Red Controller ModeUnit Wiring Basic Unit Wiring Deluxe Unit Wiring ZN510 460 V-60 HZ-3 PH Unit Wiring ZN524SV-UN-WSHP-SVX01C-0104 Trane

GEV, GEH specifications

Trane has long been a leader in the HVAC industry, and their GEH and GEV series of heat pumps are a testament to their commitment to innovation and efficiency. These models are designed to provide substantial energy savings while maintaining exceptional performance, making them ideal choices for both residential and commercial applications.

The Trane GEH and GEV heat pumps feature advanced variable-speed technology, which allows them to adjust their output to match the current heating or cooling demand. This adaptability not only enhances comfort by maintaining a consistent indoor temperature but also leads to significant energy savings by reducing unnecessary energy consumption during partial-load conditions. By running more efficiently at lower speeds, these units reduce wear and tear on components, extending the lifespan of the system.

One of the defining characteristics of the GEH and GEV models is their high SEER (Seasonal Energy Efficiency Ratio) and HSPF (Heating Seasonal Performance Factor) ratings. These ratings demonstrate the units' ability to provide efficient heating and cooling throughout the year, contributing to lower energy bills. The use of R-410A refrigerant is another key feature, as it is both environmentally friendly and efficient, ensuring that these systems meet stringent regulatory standards while delivering reliable performance.

Installation flexibility is another highlight of the Trane GEH and GEV series. These units are designed to work seamlessly with existing HVAC systems, making retrofitting straightforward. Their compact design allows for easy placement, even in tight spaces, without compromising performance. Additionally, Trane's commitment to quality is evident in the construction of these heat pumps, as they are built to withstand harsh weather conditions and provide reliable service year after year.

Moreover, both the GEH and GEV models are equipped with integrated smart controls that simplify operation and maintenance. These controls allow homeowners and facility managers to monitor energy usage, adjusting settings remotely and scheduling maintenance checks to maximize efficiency. This technology not only enhances user experience but also promotes energy conservation through intelligent management.

In summary, Trane's GEH and GEV heat pumps stand out for their variable-speed technology, high efficiency ratings, installation flexibility, and smart controls. These features make them an ideal solution for those seeking a reliable, energy-efficient heating and cooling option, reflecting Trane's dedication to performance and sustainability.