Triple Bay Conventional Gas Grill Cooktop
PRODUCT MODEL NUMBERS
JGD8348CD
INSTALLATION OF CABINETRY OVER YOUR GRILL
Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18"
(45.7 cm) above the cooking surface is:
8" (20.3 cm) at sides
NOTE: This is not the recommended clearance, 18 but minimum allowable (45.7 cm) clearance.
*A = 30" (76.2 cm) minimum vertical
clearance between | 8 |
cooking surface | (20.3 cm) |
MIN. CLEARANCE |
and construction above the appliance.
B = 13" (33.0 cm) maximum depth of cabinets installed above cooking top.
Avoid use of cabinets above cooktop for storage space to eliminate associated potential hazards such as reaching over open flames.
Dotted lines indicate range hood construction.
*To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Cabinets Above Cooking Top
Maximum depth of cabinets installed above cooking top is 13" (33 cm).
MINIMUM SPACING REQUIREMENTS
For installing a TripleBay Downdraft Cooktop in combination with another Downdraft Cooktop, the minimum spacing between adjacent units must be provided, as shown, for satisfactory performance.
PROSTYLE COOKTOP
ANY DOUBLE BAY
ANY SINGLE BAY
18"
(45.7 cm)
(11.1 cm)
18"
(45.7 cm)
(41 cm)
ANY DOWNDRAFT
(11.1 cm) | COOKTOP |
| |
| (Single, Double or |
| Triple Bay) |
PROSTYLE
COOKTOP
PROSTYLE
COOKTOP
|
| Page 3 of 3 |
Because Whirlpool Corporation policy includes a continuous commitment to improve | Dimensions are for planning purposes only. For complete details, see Installation | Ref. |
our products, we reserve the right to change materials and specifications without notice. | Instructions packed with product. Specifications subject to change without notice. |