Jenn-Air JGD8348CD specifications Product Model Numbers, GAS Requirements, Product Dimensions

Page 1

Triple Bay Conventional Gas Grill Cooktop

PRODUCT MODEL NUMBERS

JGD8348CD

GAS REQUIREMENTS

Gas supply: The installation of this appliance

The maximum gas supply pressure for the

Make the gas connection to the inlet of the

must conform with local codes, or in the absence

appliance pressure regulator supplied on this

appliance pressure regulator on this appliance

of local codes, with the latest edition of the

appliance is 14" W.C. The test pressure for

with a 1/2" male pipe thread. Use an approved

National Fuel Gas Code ANSI Z223.1 USA or

checking this appliance pressure regulator must

pipe joint compound resistant to the action of LP

current CAN/CGA-B149 INSTALLATION CODE.

be at least 6" W.C. for Natural Gas, and at least

gas at pipe connections.

This appliance was adjusted at the factory for use

11" W.C. for LP. It is shipped from the factory set

Electrical: See page 2.

for Natural Gas at 5" W.C.

with natural gas. If, at any time, this appliance is

 

Install a manual shutoff valve in an accessible

 

to be used with a different type of gas, all of the

 

conversion adjustments described in the

location in the gas line external to this appliance

 

installation instructions must be made by a

for the purpose of turning on or shutting off gas

 

qualified service technician before attempting to

to the appliance.

 

operate the cooktop on that gas.

 

 

PRODUCT DIMENSIONS

 

 

 

 

 

Dimension “A” - provide 2" min. (5.1 cm) cabinet clearance to motor for cooling purpose.

NOTE: Where possible, 6" (15.5 cm) is recommended for motor/blower service.

Side Clearance: Grills installed near a side wall must allow a minimum clearance of 8" (20.3 cm).

Access must be provided to remove and empty grease container.

This appliance is designed to always be vented outdoors.

Page 1 of 3

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8101P620-60

Instructions packed with product. Specifications subject to change without notice.

09-25-08

Image 1
Contents Product Model Numbers Product DimensionsGAS Requirements Cabinet and Countertop Cutouts Electrical RequirementsMinimum Spacing Requirements Installation of Cabinetry Over Your GrillProstyle Cooktop ANY Double BAY ANY Single BAY ANY Downdraft