Brinkmann 7341 Filling the LP GAS Cylinder, Installing the LP GAS Cylinder Onto the Grill

Page 7

WARNING

FILLING THE LP GAS CYLINDER:

Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.

New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.

DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or flame an explosion causing severe burns, bodily harm, or death could occur.

Always use a protective cylinder cap when grill is not connected to cylinder.

If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an over-filling prevention device (OPD).

INSTALLING THE LP GAS CYLINDER ONTO THE GRILL:

1.Check that the cylinder valve is closed by turning the knob clockwise.

2.Place the cylinder into the tank holder in the bottom of cart base.

3. Orient the cylinder such that the valve opening faces the side burner, and so that the hose is not kinked or damaged.

4. Lift tank lock wire to secure cylinder into tank holder.

5.Attach or detach regulator to the LP gas cylinder only when cylinder is at rest in tank holder.

HOSE AND REGULATOR:

Your grill is equipped with a Type 1 connection device with the following features:

1. The system will not allow gas flow from the cylinder until a positive connection to the valve has been made.

Note: The cylinder valve must be turned off before any connection is made or removed.

2. A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F to 300°F (115°C to 150°C). If this should happen, remove the entire regulator assembly and dispose of properly. A replacement regulator assembly can be purchased by contacting customer service at 800-527-0717. The cause of the excessive heat should be determined and corrected before using your grill again.

3. A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour. If the flow limiting device is activated, perform Regulator Resetting Procedure.

REGULATOR RESETTING PROCEDURE

1.Turn burner control knobs to "OFF", turn off the cylinder valve and disconnect regulator from LP gas tank. Wait approximately two minutes.

2.Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset.

6

Image 7
Contents 7341 Important Safety Table of Contents General Warnings LP GAS Cylinder not Supplied with this Grill Installation InformationCylinder Specifications Hose and Regulator Installing the LP GAS Cylinder Onto the GrillRegulator Resetting Procedure Filling the LP GAS CylinderConnecting Hose and Regulator Connecting Hose and Regulator to AN LP GAS CylinderWhen to Perform a Leak Test Leak TestingChecking for Leaks PRE-START Check List Lighting the Main Burners Lighting InstructionsMatch Lighting the Main Burners Match Lighting the Side Burner Lighting the Side BurnerTurning OFF the Grill Controlling FLARE-UPS Operating the GrillBreaking in Your Grill Preheating the GrillSide Burner Rotisserie CookingGrilling to Proper Temperature CleanlinessHelpful Hints Burner ASSEMBLY/MAINTENANCE Cleaning and MaintenanceBefore Storing Your Grill Cooking GrillsHeat Distribution Plates Transporting and StorageTrouble Shooting Frequently Asked Questions Frequently Asked Questions Parts BAG Contents Parts List Assembly InstructionsFor Missing PARTS, Please Call Customer Service AT Step Snap wheel hubcaps onto the outside of wheels as illustrated Spring Pin Grill Body Assembly Step Step Without leak testing all Place the side burner grate onto the side burner table Step ProSeries 7341 Assembled Peligro Importantes Advertencias DE SeguridadÍndice Advertencias Generales Información DE Instalación Especificaciones DEL Cilindro Manguera Y Regulador Llenado DEL Cilindro DE GAS DE Propano LíquidoProcedimiento DE Reposición DEL Regulador Conexión DE LA Mangueray Regulador Cuándo Realizar UNA Prueba DE Detección DE Fugas Pruebas DE Detección DE FugasVerificación DE Ausencia DE Fugas ¡PRECAUCIÓN Lista DE Verificación Preliminar AL EncendidoEncendido DE LAS Hornillas Principales Instrucciones DE EncendidoEncendido DE LAS Hornillas Principales CON UN Cerillo Encendido DE LA Hornilla Lateral CON UN Cerillo Encendido DE LA Hornilla LateralApagado DE LA Parrilla Control DE LAS Llamaradas Operación DE LA ParrillaPreparación DE LA Parrilla Para Usarla POR Primera VEZ Precalentamiento DE LA ParrillaLA Hornilla Lateral Cocción Estilo RotisserieCocinar a LA Parrilla a LA Temperatura Apropiada LimpiezaRecomendaciones Útiles INSTALACIÓN/MANTENIMIENTO DE LAS Hornillas Limpieza Y MantenimientoAntes DE Guardar LA Parrilla Rejillas Para CocinarPlacas DE Distribución DEL Calor Transporte Y AlmacenajeIdentificación Y Corrección DE Problemas Preguntas Frecuentes Preguntas Frecuentes Lista DE Partes Instrucciones DE ArmadoSI Faltan PARTES, Llame a Servicio AL Cliente AL Contenido DE LA Bolsa DE Partes Paso Paso M6 x 10mm negros y arandelas de estrella negras Plateadas Paso Advertencia Bandeja para la Grasa Paso ProSeries 7341 Armada Warranty