DANGER
LEAK TESTING:
To prevent fire or explosion hazard:
•DO NOT smoke or permit ignition sources in the area while conducting a leak test.
•Perform test OUTDOORS only in a well ventilated area.
•Never perform a leak test with a match or open flame.
•Never perform a leak test while the grill is in use or while grill is still hot.
WARNING
WHEN TO PERFORM A LEAK TEST:
•After assembling your grill and before lighting for the first time, even if purchased fully assembled.
•Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
•Any time your grill has been moved.
•At least once per year or if your grill has not been used for more than 60 days.
CHECKING FOR LEAKS:
1.Create a mixture of 50% water and 50% liquid dishwashing soap.
2.Open the lid.
3.Ensure all control knobs are set to the "OFF" position.
4.Turn on the fuel supply at the cylinder valve. Turn the cylinder valve knob one turn
5.Apply the soap water mixture to the following:
ASupply tank (cylinder) weld.
BConnection nut to tank valve.
CBack side of connection nut to brass nipple.
DBrass nipple connection into regulator.
ERegulator connections to gas supply hoses.
FHose connection to gas manifold.
GThe full length of gas supply hose.
H Tank valve to cylinder. | H |
Watch For Bubbles
F
EG
D
C
B
A
8