Teledyne TED 191 instruction manual Section Nine, Humidity

Page 23

SECTION NINE

EFFECT OF

HUMIDITY

 

Humidity does not directly affect the accuracy of the sensor's measurement. However, when a nebuliser or other device is used to increase moisture levels in gas mixtures, the moisture actually dilutes the mixture. This dilution effect decreases the oxygen concentration.

For example, if an 80% oxygen gas mixture is humidified to saturation at room temperature, the resulting gas mixture will contain only 77.5% oxygen. Your TED 191 Portable Oxygen Monitor accurately measures decreases in the oxygen concentration due to the dilution effects of moisture added to gas mixtures.

As with all oxygen sensors, excessive condensation on the sensing surface will block the diffusion of oxygen to the sensor, rendering it inoperative. It is recommended that the sensor be installed on the dry side of the breathing circuit at all times.

Water condensate on the exposed cable contacts at the rear of the sensor may affect the oxygen reading and should be removed by shaking out the condensed water and allowing the sensor to air dry.

TELEDYNE ELECTRONIC TECHNOLOGIES

Analytical Instruments

23

Image 23
Contents TED All Rights Reserved Warranty StatementTable of Contents Section Topic Number Introduction Applications Front Panel Description of Functional ZonesRear Panel Section ONE Operations SET-UPInstalling the Batteries Installing the Oxygen Sensor Calibrate the Instrument Normal Operation Oxygen Monitor SET the AlarmsAnaesthetic Agents Section TWOSection Three Cleaning the TED 191 Portable Oxygen MonitorSterilising the T-7 Oxygen Sensor and Connecting Cable Section Four DO’SChanging the Oxygen Sensor Cell Section FiveRoutine Visual Inspection Changing BatteriesSection SIX Troubleshooting Remove the sensor tip from the T-adaptor, unscrew the flow Section Seven Technical Specifications Transport ServiceSensor Response Time StorageEffect of Pressure Section EightHumidity Section NineSection TEN Effect Temperature Section Eleven Discrepancy Readings Section Twelve Repair Service Sensor Cell Replacement LOG Technical Service LOG General Notes Spare Parts Spare Parts ListOptional Accessories

TED 191 specifications

The Teledyne TED 191 is an innovative device designed to enhance various technologies in the realms of data acquisition and signal processing. This cutting-edge equipment has garnered attention for its outstanding performance, robustness, and versatility, making it a popular choice among professionals in numerous industries, including aerospace, military, and environmental monitoring.

The TED 191 features a compact form factor, enabling easy integration into existing systems without requiring significant modifications or additional space. This design is especially beneficial for applications requiring portability, as the device can be seamlessly transported and deployed in the field. Moreover, its rugged construction provides durability and reliability under harsh operating conditions, ensuring consistent performance even in challenging environments.

One of the standout characteristics of the Teledyne TED 191 is its advanced signal processing capabilities. The device is equipped with high-resolution analog-to-digital converters that enable the capturing of intricate waveforms with precision and accuracy. This is crucial for applications such as seismic monitoring and geophysical surveying, where minute variations in signals can carry significant implications.

In addition to its robust data acquisition features, the TED 191 supports multiple communication protocols, allowing for seamless integration with other systems and devices. This interoperability ensures that users can easily transfer data and remotely control the device, enhancing operational efficiency. The device is compatible with various software applications, further expanding its utility for users who require specialized analytics or data visualization.

Another notable technology embedded in the TED 191 is its real-time processing capabilities. This allows users to analyze incoming data instantaneously, facilitating timely decision-making. This feature is particularly valuable in critical applications like military operations and emergency response scenarios, where seconds count, and immediate information can influence outcomes.

In summary, the Teledyne TED 191 stands out as a highly capable tool for professionals demanding high performance and reliability in data acquisition and signal processing. Its compact design, advanced signal processing technologies, interoperability, and real-time analysis capabilities make it an essential device across various sectors. As industries continue to evolve and seek out cutting-edge technologies, the TED 191 remains at the forefront, setting a standard for performance and versatility.