Specifications

Model

: 1134

Power source

: 4 "AA" Alkaline batteries or AC/DC

 

adapter

Measurement method

: Oscillometric

Measurement range

: Pressure: 20~280 mmHg

 

Pulse: 40~195 beats/minute

Accuracy

: Pressure: ±3 mmHg

 

Pulse: within ±5% of reading

Pressure sensor

: Semi-conductor

Inflation

: Pump driven

Deflation

: Automatic Pressure release valve

Auto shut-off

: 3 minutes after last key operation

Operating environment

: 50˚F~104˚F / 30%~85% RH max.

Storage environment

: -20˚C~60˚C (14˚F~140˚F)

 

10%~95% RH max.

Weight

: 344g (w/o batteries), cuff 120g

Arm circumference

: 9.2" ~18.2"

Users

: Adults

Dimensions

: 5.3" (L) x 4.8" (W) x 6"(H)

PC-Link

: Via USB plug & software. (available

 

separately)

*Specifications are subject to change without notice.

Two Year Limited Warranty

25

 

 

Lumiscope guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase, except as noted below:

This Lumiscope product warranty does not cover damage caused by misuse or abuse, the attachment of any unauthorized accessory, alteration to the product, or any other conditions whatsoever that are beyond the control of Lumiscope. Lumiscope shall not be responsible for any type of incidental, consequential, or special damage. All implied warranties, including, but not limited to those implied warranties of fitness and merchantability,

are limited to the total duration of two years from the original date of purchase.

To obtain warranty service on your Lumiscope Blood Pressure Monitor, please contact the Lumiscope Repair Department at 1-800-672-8293 or visit www.lumiscope.net. There is a $15 fee for return shipping and handling. Please make checks payable to The Lumiscope Co., Inc.

Upon receipt, Lumiscope will repair or replace, as appropriate, this blood pressure monitor and return it to you. Warranty is solely through the Lumiscope Repair Department. Service of this product by anyone other than the Lumiscope Repair Department voids warranty.

In the event that Lumiscope does not abide by the terms of this warranty, the consumer may seek breach of contract remedies in the New York State Federal courts of law. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

Image 14
Contents Model AccuRead Page Table of Contents Introduction3How the 1134 Works What is Blood Pressure?Why Measure Your Blood Pressure? About Blood PressureUnit Display Symbols Parts IdentificationFunctional FeaturesUnit Display Explanation To insert the batteries Installing the BatteriesCorrect Measuring Posture To Connect the AC/DC AdapterApplying the Cuff To apply the cuffShowing levels of Blood Pressure Reading WHO Lighted IndicatorTo start the measurement Irregular Heartbeat reading Irregular Heartbeat DectectionHeartbeat Readings Regular Heartbeat reading but below normalTo see the previously measured values Memory RecallAverage Recall To see the average of previously measured valuesTo set time and date Clock SettingsHow to set Alarm Clock Troubleshooting Maintaining & Storing UnitSpecifications Two Year Limited Warranty