Panasonic CW-XC54HU, CW-XC54HK Electrical Data, HOW to Secure the Drain Pipe, Removal from Window

Page 12

4. SECURE THE GUIDE PANELS

Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. 12.

5. INSTALL THE SASH SEAL AND SASH LOCK

a. Cut the sash seal (TYPE E) to the window width.

Stuff the sash seal between the glass and the

window to prevent air and insects from getting into

the room, as shown in Fig. 12.

b. Fasten the L bracket using a screw (TYPE A), as

shown in Fig. 12.

6. a. Remove the screws that secure the cabinet and

base pan in the right side.

b. Fasten the support bracket (TYPE G) using a

removed screw. Attach the support bracket (TYPE G)

in the inner window sill with a screw (TYPE B), as

shown Fig. 13.

LBRACKET TYPE A

TYPE B

Fig. 12

TYPE B

SASH SEAL

(TYPE E)

7. Window installation of room air conditioner is now

completed. See ELECTRICAL DATA for attaching

power cord to electrical outlet.

Support Bracket (TYPE G)

Fig. 13

Installation

C. HOW TO SECURE THE DRAIN PIPE

In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. (Fig. 14) Press the drain pipe into the hole by pushing down and away from the fins to avoid injury.

REMOVAL FROM WINDOW

Hang Push

DRAIN PIPE

DRAIN CAP

Fig. 14

Features and

Turn the air conditioner off, disconnect the power cord, remove the Support Bracket, L bracket and the screws installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining any condensate. Lift the air conditioner from the window and remove the sash seal from between the windows.

Electrical Data

Line Cord Plug

Use Wall Receptacle

Power Supply

Do not under any

 

 

circumstances cut

 

Use 15 AMP, time

or remove the

 

grounding prong

 

delay fuse or circuit

from the plug.

 

breaker.

 

 

Power supply cord with

Standard 125V, 3-wire grounding

 

3-prong grounding plug

receptacle rated 15A, 125V AC

 

USE OF EXTENSION CORDS

Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.

12

Image 12
Contents CW-XC54HK Safety Precautions Controls Air direction Care and MaintenanceFeatures Electrical DataSafety Precautions This could lead to health problemsIt will cause electric shock or fire due to heat generation It will cause electric shock or fireThey are sharp and may cause an injury It could cause dust to accumulate on the heat exchangerThis could injure the pets or plants It may cause deterioration of quality, etcAbout the Controls on the air conditioner ControlsMode DRY Remote controller Care and Maintenance Air DirectionFar about Features and Installation FeaturesWindow Requirements Outer Sill Indoors OutdoorsHardware Type C Qty3Before Installation NOW Start InstallationInstall the AIR Conditioner in the Window Locating Unit in a WindowHOW to Secure the Drain Pipe Electrical DataRemoval from Window USE of Extension CordsBefore you call for service Normal OperationAbnormal Operation Commandes Direction de lair Nettoyage et entretien Mesures de sécuritéCaractéristiques ÉlectriqueMesures de sécurité Tout mauvais branchement peutAppareil provoquant ainsi un Dincendie Risque délectrocution ouVous risquez de vous blesser Il y a risque de choc électriqueCommandes Instructions de fonctionnementModèle Télécommande Mode DopérationRéglage DE LA Température Économie DénergieDirection de lair Nettoyage et entretienInstructions dinstallation CaractéristiquesRainure Grillage métallique Dimensions de la fenêtre Matériel Requis Pour Linstallation25 mm / 1 po Type C Qté3Avant Linstallation Emplacement DE Lappareil Dans LA FenêtreInstallez LE Climatiseur À LA Fenêtre Attachez LES Supports EN LInstallez LA Bande ET LE Châssis Mesures de sécurité électriqueRetrait DE Lappareil Utilisation DE Cordons ProlongateursAvant de placer un appel de service Fonctionnement normalFonctionnement anormal De seguridad Controles La dirección del aireMantenimiento CaracterísticasEsto podría dirigir al problema de la salud Puede ocasionar una descarga eléctricaEsto podría causar heridas Esto podría dañar al animal o a la plantaInstruccionnes de Funcionamiento ControlesMarcador DE ENCENDIDO/APAGADO ENECNDIDO/APAGADOEnfriando Control remoto Ajuste DE LA TemperaturaFRÍO/VENTILADOR/SECO Ahorrador DE EnergíaLa dirección del aire Cuidado y MantenimientoPara Limpiar EL Filtro Limpieza DEL Aire AcondicinadoChannel tube Wire net Requerimientos de la VentanaCaracterísticas Requerimientos de la ventana MAX PulgAntes DE Instalar Empieze LA InstlacionColoque EL Ménsula EN L Instale EL Aire Acondicionado a LA VentanaInformacion Electrica Antes de avisar al Servicio Técnico Operación normalOperación anormal Memo Memo Memo Dimensions DimensionesNET Weight Gross WeightRef Acwar 11/03 Ref. AcwarFr 11/03 America Ave de Infanteria, Km

CW-XC54HK, CW-XC54HU specifications

The Panasonic CW-XC54HK and CW-XC54HU are cutting-edge air conditioning solutions that exemplify modern innovation in climate control. Known for their efficiency, these models are designed to provide superior cooling and heating performance in residential and commercial spaces.

One of the standout features of these models is their powerful inverter technology. This allows the units to adjust their cooling and heating output based on the room’s temperature, ensuring that energy consumption is minimized while maintaining comfort. The inverter system is more efficient than traditional fixed-speed units, which means that users can enjoy lower energy bills without sacrificing performance.

Both the CW-XC54HK and CW-XC54HU are equipped with a high-efficiency air filter that helps in purifying the air. This is particularly beneficial for those who suffer from allergies or respiratory issues, as the filters capture dust, pollen, and other airborne particles, enhancing indoor air quality. Additionally, the filters are easy to clean and maintain, prolonging the system’s life while ensuring optimal performance.

Another key characteristic of these models is their quiet operation. Panasonic has engineered the CW-XC54HK and CW-XC54HU to run at low noise levels, making them ideal for bedrooms, offices, and other environments where noise disruption is a concern. The incorporation of silent fan technology further adds to this feature, offering users a peaceful atmosphere.

The sleek and modern design of these units ensures they fit seamlessly into any interior décor. With a user-friendly remote control, operating the air conditioning system becomes incredibly convenient. The models also feature various modes, including cooling, heating, dehumidifying, and auto mode, which can easily be selected based on the user’s needs.

Energy efficiency is a significant consideration for many consumers today, and both the CW-XC54HK and CW-XC54HU boast impressive energy ratings. They utilize advanced refrigerants that not only enhance cooling efficiency but are also environmentally friendly, aligning with global efforts to reduce the carbon footprint.

In summary, the Panasonic CW-XC54HK and CW-XC54HU represent the pinnacle of air conditioning technology, combining efficiency, design, and user-friendly features. These models are perfect for anyone looking to find a reliable and effective solution for their temperature control needs.