Panasonic CU-C9CKP5 manual Operating Instructions, Safety Precautions, Name of Each Part

Page 1

CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6

9 Operating Instructions

SAFETY PRECAUTIONS

Before operating, please read the following “Safety Precautions” carefully.

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:

!Warning

This sign warns of death or serious injury.

!Caution

This sign warns of damage to property.

The instructions to be followed are classified by the following symbols:

This symbol (with a white background) denotes an

action that is PROHIBITED.

OFF

These symbols (with a black background) denote

actions that are COMPULSORY.

Installation Precautions

!Warning

Do not install, remove and reinstall the unit by yourself.

Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work.

!Caution

This room air conditioner must be

earthed.

Improper grounding could cause electric shock.

Ensure that the drainage piping is connected properly.

Otherwise, water will leak out.

Do not install the unit in a potentially explosive atmosphere. Gas leak near the unit could cause fire.

Operation Precautions

!Warning

This sign warns of death or serious injury.

Do not share outlet.

Do not insert plug to operate the unit. Do not pull out plug to stop the unit.

Do not operate with wet hands.

Do not damage or modify the power cord. Do not insert finger or other objects into the

indoor or outdoor units.

Do not expose directly to cold air for a long period.

Plug in properly.

Use specified power cord.

OFF If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power

supply.

!Caution

This sign warns of injury.

Do not pull the cord to disconnect the plug. Do not wash the unit with water.

Do not use for other purposes such as preservation.

Do not use any combustible equipment at airflow direction.

Do not sit or place anything on the outdoor unit.

Switch off the power supply before cleaning. Ventilate the room regularly.

Pay attention as to whether the installation rack is damaged after long period of usage.

OFF Switch off the power supply if the unit is not

used for a long period.

NAME OF EACH PART

Indoor Unit

Indoor Unit

 

 

(when the front panel is opened)

1

2

 

 

1

3

 

3

 

 

2

 

7 6 5 4

Accessories

Remote Control

 

 

 

 

 

 

AUTOH

 

 

 

 

 

 

 

ON

EAT

C

 

 

 

 

 

 

OFF

AUTOOLO

DR

 

 

 

 

 

 

 

 

YFAN

 

 

 

 

 

TEMP

A

 

 

 

 

 

 

 

FANUTO

 

 

 

 

MODE

 

OFF/O

 

 

 

Step

 

AIR S

WING ECONOMY

N

 

 

1

 

 

 

 

ON

 

 

 

 

SLEEP

 

 

 

OFF

 

2

 

FANSPE

 

 

 

 

 

 

 

ED

 

 

 

T

 

 

SET

3

 

 

 

IMER

 

 

 

 

 

 

 

 

CANCEL

 

 

 

 

 

 

 

+

 

 

 

 

 

 

Remote Control Indication Sticker

1 Front Panel

2 Air Intake Vent

3 Power Supply Cord

4 Air Outlet Vent

5 Vertical Airflow Direction Louver

6 Horizontal Airflow Direction Louver (manually adjusted)

7 Indicator Panel

12 3 456

1 Auto Operation Button

(when the front panel is opened)

2 Powerful Mode Indicator

ORANGE

3 Ionizer Mode Indicator

GREEN

4 Power Indicator

GREEN

5 Quiet Mode Indicator

ORANGE

6 Timer Mode Indicator

ORANGE

1 Front Panel

2 Air Filters

3 Air Purifying Filter

Outdoor Unit

1

2

 

Remote Control Holder

 

3

6

4

 

 

5

 

Two RO3 (AAA) dry-cell batteries or equivalent

1 Air Intake Vents

2 Ground TerminalAir Purifying Filter

(Inside cover)

3Piping

4Connecting Cable

5Drain Hose

6Air Outlet Vents

(Catechin Air

(Triple Deodorizing

Purifying Filter)

Filter)

32

Image 1
Contents Operating Instructions Safety PrecautionsName of Each Part Preparation Before Operation Remote ControlIndoor Unit Convenience Operation Setting the TimerHelpful Information Care and MaintenanceNormal Operation TroubleshootingAbnormal Operation Call the Dealer ImmediatelySafety Precautions Installation Instructions

CS-C12CKP, CS-C9CKP, CS-C7CKP, CU-C9CKP6, CU-C12CKP6 specifications

The Panasonic CU-C9CKP5 and CS-C9CKP, along with the CU-C7CKP5 and CS-C7CKP, are a series of high-performance air conditioning units designed for both residential and commercial applications. These models are equipped with cutting-edge technologies, ensuring efficient cooling and heating, along with enhanced energy-saving features.

One of the key features of these Panasonic models is the inverter technology. This advanced system allows the units to adjust their compressor speed dynamically based on the room's temperature, resulting in significant energy savings. By avoiding the constant on-and-off cycling typical of traditional air conditioners, Panasonic's inverter technology not only reduces energy consumption but also provides consistent comfort.

In terms of cooling capacity, the CU-C9CKP5 and CU-C9CKP6 are designed for larger spaces, offering robust performance ideal for open concept living areas or commercial environments. The CU-C7CKP5 and CU-C7CKP provide slightly lower capacities, making them perfect for medium-sized rooms, ensuring users can find the right model for their specific needs.

These units also incorporate an advanced air purification system. Panasonic's air filters effectively capture dust and allergens, enhancing indoor air quality. The nanoe™ technology adds another layer of purification, releasing hydroxyl radicals that neutralize bacteria and viruses, making the air healthier for occupants.

Additionally, the CU-C9CKP5, CS-C9CKP, CU-C7CKP5, and CS-C7CKP come with user-friendly control options. With wireless remote controls and compatibility with smart home systems, users can easily adjust settings and monitor energy usage from their smartphones. This connectivity empowers homeowners to optimize their comfort while being energy-conscious.

Moreover, these models boast a sleek, modern design that blends seamlessly into any décor. The compact exterior cabinet allows for flexible installation options, making it suitable for various wall-mounted or floor-standing configurations.

Overall, the Panasonic CU-C9CKP5, CS-C9CKP, CU-C7CKP5, and CS-C7CKP, along with the CU-C9CKP6, stand out in the HVAC market for their innovative technology, energy efficiency, and commitment to superior indoor air quality. These features make them an excellent choice for those seeking reliable and effective climate control solutions.