Panasonic CS-C7CKP, CU-C7CKP5, CU-C9CKP5 Troubleshooting, Normal Operation, Abnormal Operation

Page 5

CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6

TROUBLESHOOTING

Normal Operation

Is it okay?

Air conditioner has been restarted, but does not operate for 3 minutes.

A sound like water flowing can be heard.

It seems that fog is coming out from the air conditioner.

The room has a peculiar odour.

During Automatic Vertical Airflow setting, indoor fan stops occasionally.

The outdoor unit emits water or steam.

(For Heat Pump Model only)

Operation stops for about 12 minutes during heating (The power indicator blinks).

(For Heat Pump Model only)

During heating operation, indoor fan may run at on and off conditions.

Abnormal Operation

Is it okay?

The air conditioner does not operate.

Air conditioner produces loud noise during operation.

The air conditioner does not cool or warm effectively.

Remote control / display doesn’t work

This is the answer

This is to protect the air conditioner. Wait until the air conditioner begins to operate.

• This is the sound of refrigerant flowing inside the air conditioner.

• Condensation occurs when the airflow from the air conditioner cools the room.

• This may be a damp smell emitted by the wall, carpet, furniture or clothing in the room.

• This is to remove smell emitted by the surroundings.

• In COOL/DRY operation, moisture in the air condenses into water on the cool surface of outdoor unit piping that causes dripping.

• This is to melt the frost which has accumulated on the outdoor unit (defrosting operating). This will take no longer than about 12 minutes. Water drips from the outdoor unit. Wait until this operation ends. (the power indicator will light up).

(Frost will accumulates on the outdoor unit when the outdoor temperature is low and humidity is high.)

• This is to prevent undesired cooling effect during heating operation.

Please check

• Has the circuit breaker been tripped?

Has the power plug been removed from the wall outlet?

Is the timer being used correctly?

• Is the installation work slanted?

Is the front grille closed properly?

• Has the temperature been set incorrectly?

Are the filters dirty?

Are the intake or outlet vents of the outdoor unit obstructed?

Are all windows and doors closed?

• Batteries empty?

Batteries correctly inserted (+) and (–)?

Call the Dealer Immediately

If the following conditions occur, turn off and unplug the main power supply, and then call the dealer immediately.

Abnormal noise is heard during operation.

Water or foreign material gets into the remote control by mistake.

Water leak from the indoor unit.

Switches or buttons do not operate properly.

The circuit breaker switches off frequently.

Power supply cord and plug become unusually warm.

36

Image 5
Contents Name of Each Part Safety PrecautionsOperating Instructions Indoor Unit Remote ControlPreparation Before Operation Convenience Operation Setting the TimerHelpful Information Care and MaintenanceNormal Operation TroubleshootingAbnormal Operation Call the Dealer ImmediatelySafety Precautions Installation Instructions

CS-C12CKP, CS-C9CKP, CS-C7CKP, CU-C9CKP6, CU-C12CKP6 specifications

The Panasonic CU-C9CKP5 and CS-C9CKP, along with the CU-C7CKP5 and CS-C7CKP, are a series of high-performance air conditioning units designed for both residential and commercial applications. These models are equipped with cutting-edge technologies, ensuring efficient cooling and heating, along with enhanced energy-saving features.

One of the key features of these Panasonic models is the inverter technology. This advanced system allows the units to adjust their compressor speed dynamically based on the room's temperature, resulting in significant energy savings. By avoiding the constant on-and-off cycling typical of traditional air conditioners, Panasonic's inverter technology not only reduces energy consumption but also provides consistent comfort.

In terms of cooling capacity, the CU-C9CKP5 and CU-C9CKP6 are designed for larger spaces, offering robust performance ideal for open concept living areas or commercial environments. The CU-C7CKP5 and CU-C7CKP provide slightly lower capacities, making them perfect for medium-sized rooms, ensuring users can find the right model for their specific needs.

These units also incorporate an advanced air purification system. Panasonic's air filters effectively capture dust and allergens, enhancing indoor air quality. The nanoe™ technology adds another layer of purification, releasing hydroxyl radicals that neutralize bacteria and viruses, making the air healthier for occupants.

Additionally, the CU-C9CKP5, CS-C9CKP, CU-C7CKP5, and CS-C7CKP come with user-friendly control options. With wireless remote controls and compatibility with smart home systems, users can easily adjust settings and monitor energy usage from their smartphones. This connectivity empowers homeowners to optimize their comfort while being energy-conscious.

Moreover, these models boast a sleek, modern design that blends seamlessly into any décor. The compact exterior cabinet allows for flexible installation options, making it suitable for various wall-mounted or floor-standing configurations.

Overall, the Panasonic CU-C9CKP5, CS-C9CKP, CU-C7CKP5, and CS-C7CKP, along with the CU-C9CKP6, stand out in the HVAC market for their innovative technology, energy efficiency, and commitment to superior indoor air quality. These features make them an excellent choice for those seeking reliable and effective climate control solutions.