ReliOn instruction manual Specifications, 7100REL HEM-7102-WM

Page 24

SPECIFICATIONS

Model:

7100REL (HEM-7102-WM)

Display:

LCD Digital Display

Measurement Range:

Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.

Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading

 

Pulse: ±5% of reading

Inflation:

Automatic by electric pump

Deflation:

Automatic pressure release valve

Rapid Air Release:

Automatic exhaust valve

Pressure Detection:

Capacitive pressure sensor

Measurement Method:

Oscillometric method

Pulse Wave Detection:

Capacitance type pressure sensor

Power Source:

1.5 V 4 “AAA” batteries

Battery Life:

Approx. 300 uses when used once a day for 2 minutes

 

with 4 new alkaline batteries

Operating Temperature

50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH

/Humidity:

 

Storage Temperature

-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH

/Humidity/Air Pressure: /700 - 1060 hPa

Main Unit Weight:

Approximately 12 oz. (340 g) not including batteries

Main Unit Dimensions: Approximately 4 1/8" (l) × 4 7/8" (w) × 3 1/8" (h)

 

(103 mm × 125 mm × 80 mm)

Cuff Size:

Approximately 5 3/4" (w) × 17 1/2" (l)

 

(146 mm × 446 mm)

 

Cuff tube 23 5/8" (600 mm)

Cuff Circumference:

Fits arm circumferences 9" to 13" (220 mm to 320 mm)

Contents:

Main Unit, Cuff, Instruction Manual and 4 “AAA”

 

batteries

NOTE: These specifications are subject to change without notice.

24

Image 24
Contents Automatic Blood Pressure Monitor Model 7100REL Table of Contents Introduction Staple your purchase receipt hereSafety Information Operating the DeviceOperating the Device Care and Maintenance Before Taking a Measurement Know Your Unit ComponentsUnit Display Display Symbols AHA Home Guideline for Upper Limit of Normal BPBattery Installation Battery Replacement Applying the ARM Cuff Applying the Cuff on the Left ARMInch 1 2 cm Blue Arrow Applying the Cuff on the Right ARM Taking a Measurement Taking a Measurement Using the Memory Function To Display the Measurement ValuesCare and Maintenance Error Indicators and Troubleshooting Tips Symbol Cause CorrectionProblem Causes and Solutions FCC Statement Warranty Specifications 7100REL HEM-7102-WMPage Omron HEALTHCARE, INC Manual DE Instrucciones Índice Antes de usar el monitorIntroducción Guarde Estas InstruccionesInformación DE Seguridad Operación DEL DispositivoOperación DEL Dispositivo continuación Cuidado Y Mantenimiento Antes DE Tomar UNA Medición Conozca LA Unidad Unidad principalPantalla DE LA Unidad Símbolos DE LA Pantalla Símbolo DE CorazónColocación DE LAS Pilas Cambio DE LAS Pilas PrecauciónColocación DEL Brazalete Para EL Brazo Pulgada 1 2 cm Flecha azul Colocación DE LA Banda Para EL Brazo Cómo Tomar UNA Medición Cómo Tomar UNA Medición USO DE LA Función DE Memoria Para Mostrar LOS Valores DE MediciónCuidado Y Mantenimiento Indicadores DE Error Y Solución DE Problemas Símbolo Causa CorrecciónProblema Causas Y Soluciones Declaración DE FCC NotaGarantía Especificaciones Notas E255322687-0A