Panasonic CU-2E18NBU service manual CapacitykW

Page 44

šCooling Characteristic

[Condition] Room temperature: 81°F (DBT), 66°F (WBT) Operation condition: High fan speed Piping Length: 24.6ft

Compressor Freq: Fc

B) Indoor unit capacity: Cooling (3.2 + 3.2: CS-E12NKUAW + CS-E12NKUAW), service mode frequency = 46Hz

 

 

 

 

 

 

 

 

 

 

 

208

 

230

 

 

62.000

 

 

 

 

 

 

 

 

 

 

 

 

 

61.000

 

 

 

 

 

 

 

 

 

 

 

Outlet Air

(°F)

60.000

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

59.000

 

 

 

 

 

 

 

 

 

 

 

58.000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57.000

 

 

 

 

 

 

 

 

 

 

 

 

 

56.000

 

 

 

 

 

 

 

 

 

 

 

 

 

60

65

70

75

80

85

90

95

100

105

110

115

 

 

 

 

 

 

Outdoor Air Temperature (°F)

 

 

 

 

 

6.200

 

 

 

 

 

 

 

 

 

 

 

 

5.700

 

 

 

 

 

 

 

 

 

 

 

Cooling

5.200

 

 

 

 

 

 

 

 

 

 

 

Capacity(kW)

 

 

 

 

 

 

 

 

 

 

 

 

4.700

 

 

 

 

 

 

 

 

 

 

 

 

4.200

 

 

 

 

 

 

 

 

 

 

 

 

60

65

70

75

80

85

90

95

100

105

110

115

 

 

 

 

 

Outdoor Air Temperature (°F)

 

 

 

 

 

 

8.200

 

 

 

 

 

 

 

 

 

 

 

 

 

7.700

 

 

 

 

 

 

 

 

 

 

 

 

 

7.200

 

 

 

 

 

 

 

 

 

 

 

Current

 

6.700

 

 

 

 

 

 

 

 

 

 

 

(A)

6.200

 

 

 

 

 

 

 

 

 

 

 

5.700

 

 

 

 

 

 

 

 

 

 

 

 

 

5.200

 

 

 

 

 

 

 

 

 

 

 

 

 

4.700

 

 

 

 

 

 

 

 

 

 

 

 

 

4.200

 

 

 

 

 

 

 

 

 

 

 

 

 

3.700

 

 

 

 

 

 

 

 

 

 

 

 

 

60

65

70

75

80

85

90

95

100

105

110

115

 

 

 

 

 

 

Outdoor Air Temperature (°F)

 

 

 

 

 

 

159.000

 

 

 

 

 

 

 

 

 

 

 

 

 

157.000

 

 

 

 

 

 

 

 

 

 

 

Gas Side Piping

Pressure (PSI)

155.000

 

 

 

 

 

 

 

 

 

 

 

153.000

 

 

 

 

 

 

 

 

 

 

 

151.000

 

 

 

 

 

 

 

 

 

 

 

149.000

 

 

 

 

 

 

 

 

 

 

 

147.000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

145.000

 

 

 

 

 

 

 

 

 

 

 

 

 

143.000

 

 

 

 

 

 

 

 

 

 

 

 

 

60

65

70

75

80

85

90

95

100

105

110

115

 

 

 

 

 

 

Outdoor Air Temperature (°F)

 

 

 

 

44

Image 44
Contents CU-2E18NBU Disassembly and Assembly Instructions Safety Precautions Page Specifications CU-2E18NBUš Multi split combination possibility Volume Dimensions Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Electronic Circuit Diagram Printed Circuit Board Main Printed Circuit BoardPage Installation Information Check PointsOutdoor Unit Installation InstructionSelect The Best Location Install The Outdoor Unit Connect the PipingEvacuation of the Equipment Cutting and Flaring the PipingConnect The Cable To The Outdoor Unit Heat InsulationOperation Control Cooling OperationOutdoor fan control Annual Cooling controlPowerful Operation Heating OperationOperation mode priority control Simultaneous Operation ControlElectronic Parts Temperature Rise Protection 1 Cool Electronic Parts Temperature Rise Protection 2 CoolProtection Control Freeze Prevention control CoolCooling overload control Cool Heating overload control HeatTime Delay Safety Control Restart Control IPM power transistor Protection ControlDeice Control 13.10 30 seconds Force OperationCompressor discharge high pressure protection control Compressor Protection Control Gas leak detection controlValve close detection control Servicing Mode 14.1 CU-2E18NBUPump down operation SW1 Test Run operationWiring Error check Power Save ModeMode priority function Cooling only functionTroubleshooting Guide Self Diagnosis FunctionPage Page Disassembly and Assembly Instructions Outdoor Unit Removal ProcedureRemoving the Cabinet Top Plate and Cabinet Front Plate Remove the Control Board Cover and Particular PlatesRemoving the Control P.C. Board Removing the Propeller Fan and Fan MotorPage One Indoor Unit Operation Technical DataOperation Characteristics 133.000 128.000 100 105 110 115 Outdoor Air Temperature F š Piping Length Characteristic Cooling š Piping Length Characteristic Cooling š Heating Characteristic š Heating Characteristic š Piping Length Characteristic Heating š Piping Length Characteristic Heating Two Indoor Unit Operation CapacitykW š Cooling Characteristic š Piping Length Characteristic Cooling š Piping Length Characteristic Cooling š Piping Length Characteristic Cooling š Heating Characteristic š Heating Characteristic š Heating Characteristic š Piping Length Characteristic Heating š Piping Length Characteristic Heating š Piping Length Characteristic Heating Exploded View and Replacement Parts List REF. no Description & Name ’TY CU-2E18NBU Remark Accessory CO. Drain Elbow

CU-2E18NBU specifications

The Panasonic CU-2E18NBU is a highly efficient outdoor unit designed for residential and commercial applications, providing reliable heating and cooling year-round. This unit is part of Panasonic's extensive range of HVAC solutions, known for their innovation and energy efficiency.

One of the standout features of the CU-2E18NBU is its advanced inverter technology. This technology allows the system to adjust the compressor speed based on the temperature demand, resulting in reduced energy consumption and enhanced comfort. By continuously varying the output, the inverter system maintains a consistent indoor climate without the frequent on/off cycles typical of conventional systems. This not only saves energy but also extends the lifespan of the unit.

The CU-2E18NBU is designed to operate efficiently in a wide range of conditions, showcasing excellent performance in harsh climates. With a capacity of 18,000 BTU, it can efficiently cool or heat spaces effectively, making it suitable for medium-sized rooms or multiple areas when paired with compatible indoor units.

Another significant characteristic of this Panasonic model is its environmentally friendly refrigerant, R32. This refrigerant has a lower impact on global warming and ozone depletion compared to older options, making the CU-2E18NBU a smart choice for eco-conscious consumers. R32 also enhances the system's efficiency, further contributing to lower energy costs.

The unit features a robust construction, allowing it to withstand outdoor conditions while promoting durability. Its compact design allows for flexible installation options, making it easier to fit in various environments without compromising aesthetic appeal.

Moreover, the CU-2E18NBU incorporates advanced air filtration and purification technologies, improving indoor air quality. The filters are designed to capture dust, allergens, and other particulates, ensuring cleaner, healthier air.

In summary, the Panasonic CU-2E18NBU stands out for its efficient inverter technology, environmentally friendly refrigerant, and compact, durable design. With its ability to provide consistent temperature control and improve indoor air quality, this unit is a reliable solution for anyone looking to enhance their heating and cooling systems.