Panasonic CU-2C24DKU manual Safety Precautions, Installation Precautions, Operation Precautions

Page 2

Important notice

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as below:

Warning

This sign warns of death or

serious injury.

Thank you for purchasing a Panasonic Air Conditioner

SAFETY PRECAUTIONS

Installation Precautions

Warning

 

Do not install, remove or reinstall the unit by yourself.

Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.

This equipment must be earthed and installed with ELCB. It may cause electrical shock or fire in case of malfunction.

Caution

This air conditioner must be grounded. Improper grounding will cause electric shock.

Ensure that the drainage piping is connected properly. Otherwise, water will leak.

• Do not install the unit in a potentially explosive environment.

Caution

This sign warns of injury or

damage to property.

The instructions to be followed are classified by the following symbols:

This symbol denotes an

action that is PROHIBITED.

Operation Precautions

Do not share power outlet.

Do not modify power cord.

Do not use an extension cord.

Do not operate with wet hands.

Do not insert fingers or other objects into the indoor or outdoor unit.

Do not attempt to repair the unit by yourself.

Do not use rechargeable (Ni-Cd) batteries.

Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.

Warning

Use specified supply cord.

If the supply cord is damaged or needs replacement, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Remove the batteries if the unit is not going to be used for a long period of time.

New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.

In case of emergency or if an abnormal

condition (burnt smell, etc) occurs, turn off the power supply.

These symbols denote

actions that are

COMPULSORY.

Do not wash the unit with water, benzene, thinner or scouring powder.

Do not use for other purposes such as preservation of food.

Do not store or use any combustible equipment in the airflow direction.

Do not sit on or place anything on the indoor or outdoor unit.

Do not expose directly to cold air for a long period.

Caution

Ventilate the room regularly.

Pay attention as to whether the installation rack is damaged after a long period of usage.

Switch off the power supply before cleaning or servicing.

Turn off the power supply if the unit is not going to be used for a long period of time.

Safety Regulation

The appliance is not intended for use by young children or infirm people without supervision. Young children should be supervised to ensure that they do not play with the appliance.

Power Supply

 

 

 

 

Time Delay Fuse

 

Rated Volts

20 Amps

 

208/230 V

CS-MC12DKU/CU-2C24DKU

 

 

 

 

 

 

Operation Condition (°F)

Use this air conditioner under the following temperature range.

DBT: Dry Bulb Temperature

Indoor

 

Outdoor

WBT: Wet Bulb Temperature

DBT

 

WBT

DBT

WBT

Maximum Temperature

89.6

 

73.4

109.4

78.8

 

 

 

 

 

 

Minimum Temperature

60.8

 

51.8

60.8

51.8

 

 

 

 

 

 

2

Image 2
Contents Operating Instructions Air Conditioner Operation Precautions Safety PrecautionsInstallation Precautions Important noticeIndoor Unit Remote ControlProduct Overview Outdoor UnitSelect Set the temperatureAuto, Cool, Dry Desired Operation Start the operationPowerful Economy HOW to OperatePowerful, Quiet, Economy, Fan Speed, Air Swing FAN SpeedTimer CancelAIR Filter Care & CleaningSwitch off the power supply before cleaning AIR Purifying Filter Indoor UnitPrecauciones al Operar Medidas DE SeguridadPrecauciones al instalar DefiniciónMando a distancia Unidad interiorUnidad exterior Acerca deDetalles de funcionamiento Automático, Enfriamiento, SecadoAjuste la temperatura SugerenciaSilencioso EconómicoPotente Temporizador CancelarCancelar el temporizador seleccionado Ajuste Seleccione el temporizador on o OFFFiltro DE Aire Cuidado Y LimpiezaPanel Frontal Filtro DE Unidad Purificador DEMemo Memo NON Serviceable Criterias

CS-MC12DKU, CU-2C24DKU specifications

The Panasonic CU-2C24DKU and CS-MC12DKU are advanced air conditioning units designed for residential and commercial use, characterized by their efficient performance and innovative features. This dual-split system provides optimal climate control and is popular for its reliability and effectiveness in various environments.

One of the main features of the CU-2C24DKU and CS-MC12DKU is the inverter technology. This technology allows the compressor to operate at variable speeds rather than on a fixed setting. As a result, the units can adjust the cooling or heating output according to the actual requirements of the space, leading to reduced energy consumption and lower utility bills. The inverter system enhances comfort levels by maintaining a more consistent temperature.

Another significant characteristic is the energy efficiency rating, which typically ranges between A++ to A+++, demonstrating excellent performance in energy savings. This energy-efficient design not only reduces the environmental impact but also appeals to cost-conscious consumers looking for long-term savings.

The air conditioning units are equipped with a powerful filtration system that enhances indoor air quality. The filters effectively capture dust, allergens, and other airborne particles, contributing to a healthier living environment. Some models even incorporate a gold-fin coating on the heat exchanger to improve resistance against corrosion, ensuring durability and a longer lifespan.

Additionally, these units offer a range of operating modes, including cooling, heating, dehumidification, and fan-only modes, enhancing their versatility in various weather conditions. The quiet operation is another standout feature, making it suitable for settings where minimal noise is paramount, such as bedrooms or offices.

The user-friendly remote control and smart Wi-Fi control capabilities allow users to manage the system with ease, providing convenience in adjusting settings. The programmable timer and sleep mode functions further enhance the overall user experience, offering customization for different needs throughout the day or night.

In summary, the Panasonic CU-2C24DKU and CS-MC12DKU air conditioning units are remarkable for their inverter technology, outstanding energy efficiency, and advanced filtration systems. They are designed to provide optimal comfort while ensuring reduced energy costs and maintaining a healthy indoor environment. These features make them a popular choice among consumers seeking reliable and efficient cooling and heating solutions.