Quantum Q6 Edge HD manual To replace the batteries, Battery Installation

Page 39

V I I . C A R E A N D M A I N T E N A N C E

To replace the batteries:

1.Turn off the power to the controller.

2.Make sure that the power chair is in drive mode. See III. “Your Power Chair.”

3.Remove the front cover by squeezing the release handles (see figure 24) and lifting the foot platform bracket up and away from the power base.

4.Disconnect the quick release battery connectors. See figure 6.

5.Remove the batteries.

6.Disconnect the battery harness from each battery.

7.Connect the battery harness to the new front battery according to the battery wiring diagram. See figure 24.

WARNING! Make sure you tighten the fasteners so that the connections are secure.

8.Connect the battery harness to the new rear battery according to the battery wiring diagram. See figure 24.

9.Install the new batteries and connect the quick release battery connectors.

10.Reinstall the front cover and foot platform.

11.Charge the batteries. See VI. “Batteries and Charging.”

BATTERY WIRING DIAGRAM LABEL

 

QUICK RELEASE

 

BATTERY CONNECTORS

FRONT COVER

 

 

RELEASE HANDLES

REAR BATTERY

FRONT BATTERY

 

Figure 24. Battery Installation

Q6 Edge HD

www.pridemobility.com

39

Image 39
Contents Quantum Quick Reference Information F E T Y G U I D E L I N E SVII IIIShipping and Delivery SafetyN T R O D U C T I O N PURCHASER’S AgreementS a F E T Y Product Safety SymbolsS a F E T Y S a F E T Y Front Cover Pre-Ride Safety Check General GuidelinesModifications Weight Limitations Tire InflationIncline Information Public Streets and Roadways Freewheel ModeBraking Information Cornering InformationInclement Weather Precautions Outdoor Driving SurfacesStationary Obstacles Steps, Curbs, etc Lift Systems/Elevation Products Stairs and EscalatorsDoors ElevatorsPositioning Belts BatteriesRemovable Parts Preventing Unintended Movement Transfers Reaching and BendingAlcohol/Smoking Prescription Drugs/Physical LimitationsI . Y O U R P O W E R C H a I R Q6 Edge HD Power ChairElectrical Components Q6 Edge HD Power BaseQ6 Edge HD Electrical Components To operate the manual freewheel levers Manual Freewheel LeversA S S E M B L Y Initial AssemblyTo install the seat Seat InstallationTo secure a power chair equipped with tie-down points Power Chair Securement PointsUnoccupied Transit System Securement Points O M F O R T a D J U S T M E N T S Comfort AdjustmentsYou may need the following to make comfort adjustments Seat Height and Seat Angle AdjustmentTo change the position Manual Recline Seatback AdjustmentTo adjust the recline angle Seat PositionArmrest Height Adjustment Seatback Angle AdjustmentArmrest Width Adjustment Armrest Angle AdjustmentController Position To extend the controllerTo change the controller position Foot Platform Height Adjustment Foot Platform Depth AdjustmentFoot Platform Angle Adjustment To release the positioning belt To install the positioning beltTo adjust the positioning belt for operator comfort Positioning BeltBatteries and Charging B a T T E R I E S a N D C H a R G I N GFrequently Asked Questions FAQs Battery Break-inHow can I get maximum range or distance per charge? Why do my new batteries seem weak?„ Daily Use „ Infrequent UseWhat about shipping? How can I ensure maximum battery life?How should I store my power chair and its batteries? What about public transportation?I . C a R E a N D M a I N T E N a N C E Care and MaintenanceShould your power chair come in contact with water Temperature Monthly Checks Daily Checks Weekly Checks To check the brakesStorage Disposal of Your Power ChairCleaning and Disinfection Wheel ReplacementQ6 Edge HD Drive Wheel Battery ReplacementTo replace the batteries Battery InstallationCorrective Maintenance When to See Your Quantum Rehab Provider for ServiceT E S T E S Page Product Serial # Quality Control Q6 Edge HD