Sunrise Medical Quickie 2 Lite Re-squaring Your Casters 25, Tip-over, Turning Anti-Tip Tubes Up

Page 18

2. Re-squaring Your Casters 25 26

Gently pry cap (A) off of both caster tubes. Locate the set screw (B) inside the right caster tube and loosen using an 1/4 inch hex key. Do not remove the set screw. Simply loosen it enough to allow the teeth on the upper and lower splines (C) to clear one another. With the stem bolt loosened, the caster fork should pivot freely. Place the wheelchair on the floor so that the two rear wheels and left caster con- tact the floor. Place some weight in the seat towards the rear to help stabilize the chair. Place a square or pocket level against the flat surface of the fork and pivot the fork until it is vertical (square) 24 . With the fork vertical, engage the teeth of the two splines to the closest mating position. Make certain that the teeth are properly engaged and not crossed. Shine a bright light behind the mating spline teeth and check for proper teeth engagement. Tighten the set screw (B) to secure the spline mating position. The set screw should be tightened to 192 in-lbs. (21.7 Nm) to ensure that it does not loosen during use.

Record the teeth engagement position of the splines on the right fork, and adjust the left fork in a similar fashion to the same position. Reassemble both casters, and re-check that they are square. Replace caps.

3. Fixed Front Frame Caster Housing Adjustment 27

To reposition the caster housing hardware for Quickie 2 Lite Fixed Front

a.Remove cotter clip (D) from pin (E).

b.Using a 7/16 wrench remove two caster housing bolts (F)

c.Remove clivis pin (E).

d.Reposition caster housing hardware onto frame lining up with preset holes.

e.Insert clivis pin (E) , insert and retighten two caster housing bolts (F)

f.Reinsert cotter clip (D)

WARNING

After repositioning the caster housing always check for interference with footrest

or rear wheel. Do not operate a wheelchair that has interference with these

components. Ensure the caster fork is square (see section “N” for caster squaring instructions). Additionally, repositioning the caster housing will affect the wheel- chair’s stability. Check the stability of your wheelchair with a spotter to prevent

atip-over.

O. ANTI-TIP TUBES (OPTIONAL)

Quickie recommends anti-tip tubes for all wheelchairs.

Use a torque setting of 100 in.-lbs. when setting up the anti-tip tubes.

1.Inserting Anti-Tip Tubes Into Receiver 28

a.Press the rear anti-tip release pin (G) on the anti-tip tube so that both release pins are drawn inside.

b.Insert into the anti-tip tube receiver.

c.Turn the anti-tip tube down until release pin is positioned through the receiver mounting hole (H).

d.Insert second anti-tip tube the same way.

2.Adjusting Anti-Tip Tube Wheel 29

The anti-tip tube wheels may have to be raised or lowered to achieve proper clearance of 1 1/2" to 2".

a.Press the anti-tip wheel release pin (I) so that the release pin is drawn inside.

b.Raise or lower to one of the three predrilled holes.

c.Release pin.

d.Adjust the second anti-tip tube wheel the same way. Both wheels should be at exactly the same height.

3. Turning Anti-Tip Tubes Up 30

Turn anti-tip tubes up when being pushed by attendant, overcoming obstacles or climbing curbs.

a.Press the rear anti-tip tube release pin (J).

b.Hold pin in and turn anti-tip tube up.

c.Release pin.

d.Repeat with second anti-tip tube.

e.Remember to return anti-tip tubes to down position after completing maneuver.

I X .

 

A

25

 

 

B

 

 

26

 

 

C

E

F

27

 

D

 

 

 

28

 

G

H

 

 

29

 

I

 

 

 

30

 

J

 

108590 Rev. A

18

 

Image 18
Contents Quickie 2 Lite This manual must be given to the rider of this wheelchairIntroduction Sunrise ListensFor Answers to Your Questions II . Table of Contents Fixed Front III . Your Chair and ITS PartsQuickie 2 LITE- SWING-AWAY Footrest Backrest Tube Pneumatic Tire Aluminum HandrimIV. Notice Read Before USE General WarningsWhen YOU Need Help Changes & AdjustmentsMotor Vehicle Safety Environmental ConditionsVI . Warnings Falls & TIP Overs Transfer Moving BackwardRAMPS, Slopes & Sidehills Curbs & StepsVII . Warnings for Safe USE Viii . Warnings Components and Options Positioning Belts Optional Transit USETransit Option Push Handles OptionalModified Seat Systems Upholstery FabricTo Mount & Remove Rear Wheels 1 IX . SET- UP, Adjustment & USERear Wheel Axle NUT Adjustment 3 Padded SWING-AWAY Armrests OptionalAdjusting Armrest Receiver Fit Fixed Front Footrest Height AdjustmentHeight Adjustment Replacing ArmrestAngle Adjustable Footplates Angle Adjustable Backrest OptionalBackrest Cushion Installation Optional Seat SlingRear Axles Wheel Locks Seat Height AdjustmentAdjusting Caster Angle 23 CastersTip-over Adjusting Anti-Tip Tube WheelRe-squaring Your Casters 25 Inserting Anti-Tip Tubes Into ReceiverPlastic Side Guards Optional Folding and UnfoldingCHECK-OUT Troubleshooting Make sure tire pressure is correct and equal in bothXI . Maintenance XII . Sunrise Limited Warranty Page Sunrise Medical Inc