Millennium Enterprises A1 service manual Millennium LCD Error Codes

Page 7

LCD Error Codes

Listed below are codes that the lift controller outputs during lift operation. The codes will be displayed on an LCD screen located on the lift control board inside the pump module. See the Manual Operating Instructions in the operator's manual for pump cover removal instructions.

Millennium LCD Error Codes

Non-Flashing Numbers

01 – Platform Stowed

02 – Platform Unfolding

03 – Platform Unfolding Paused

04 – Platform at Floor Level

05 – Platform Beginning to Lower

06 – Platform Lowering (Threshold Cannot Be Occu- pied from this Point Down)

07 – Outer Barrier Moving to Horizontal Position

08 – Platform at Ground Level

09 – Outer Barrier Moving to Vertical Position

10 – Platform Raising

11 – Platform Raising Paused at Floor

12 – Platform Folding (limited pressure)

13 – Platform Folding (full pressure)

14 – Timed Fold (Cinching Lift Tite) or (Anti-Rattle State)

15 – Platform Folding Stopped

28– Illegal Function/Not Defined

29– Interlock Fault Not Recognized

30– Platform Location Unknown

31– Platform Location Transition State; Attempting to Locate Position

50 – Outboard Barrier Is Not Up When Tower 4 LED Is Not On

51 – Threshold is Occupied When Tower 2 LED Is Not On

52 – Inboard Barrier Is Not Up and Locked When Tower 1 and Tower 4 LED’s Are On

53 – Inboard Barrier Occupied Sensor Is Not Activated

When Tower 1 and Tower 2 LED’s Are On 54 – Outboard Barrier is Occupied Before it is Up

55 – Outboard Barrier in Not Up When the Outboard Barrier Latch is Down

56 – Outboard Barrier is Not Latched and trying to go down after the hand control button has been re- leased. Must reset by pressing the Up button until the outboard barrier is latched, then press down so the platform goes to the ground level and the outboard barrier is deployed

75 – Low Voltage Detected; must turn off power switch to reset LCD

77 – Vehicle Secure Interlock has not been activated

99 – Controller Program is not Valid; Replace Controller

Flashing Numbers

Flashing 65 – Unfold button is pressed Flashing 66 – Fold button is pressed Flashing 67 – Down button is pressed Flashing 68 – Up button is pressed Flashing 69 – Bridge switch is activated

Flashing 70 – Outboard barrier latch switch is activated Flashing 72 – Outboard barrier up switch is activated Flashing 73 – Inboard barrier up switch is activated Flashing 74 – Inboard barrier occupied switch is acti-

vated

Flashing 76 – Outboard barrier occupied switch is activated

Flashing 78 – Threshold tape switch “A” is activated Flashing 79 – Threshold tape switch “B” is activated Flashing 83 – Tower #1 switch is activated Flashing 84 – Tower #2 switch is activated Flashing 85 – Tower #3 switch is activated Flashing 86 – Tower #4 switch is activated

Page 5

Image 7
Contents CA Congratulations Warranty and Registration Instructions#ONTENTS Switch BOX Lift Electrical SchematicPressure Switch Lift Wiring DiagramSwitch and Sensor Locations Millennium LCD Error Codes LCD Error CodesDescription Symbol Hydraulic SchematicQty Description Hydraulics Parts ListHydraulics Diagram Qty Description Pump Module Parts ListPump Mounting Bolts Pump Module DiagramPart Numbers of Items Dedicated per Lift Model Repair Parts ListLift Exploded View Providing Access to the World CA