Emerson Process Management I-0320 Viii Troubleshooting, Actuator Does Not Align Plug 130 to Port

Page 13

VIII TROUBLESHOOTING

A.Actuator Does Not Align Plug (130) to Port.

1.Check the multiport/actuator connector for looseness.

2.Check the Switchpak/actuator connector for looseness.

3.Check the motor for stalling or overload.

4.Check the speed reducer for visual leakage or noisy gear.

5.Check the accuracy of the position encoder itself (see manual RD-00232, “MultiPort Electronic Controller with MP-800 Board).

6.Refer to the Multiport Electronic Controller service manual (RD-00232) for port calibration procedures.

B.Plug Seal Assembly Leaks.

1.Refer to specification for rated differential pressure limitations.

2.Check the indicator plate and pin to ensure that the plug is aligned with the port .

3.Check the seal for damage (CAUTION: Ensure that all pressures in the Multiport body, group outlet, and test port are ZERO before visually checking the seal). With the multiport selector and piping at zero pressure, remove the test port blind flange and visually check for plug seal assembly damage (ie. Scratches) as the plug seal passes the test port .

4.If more information is required contact the factory.

C.Plug to Bonnet Stem Seal Leaks to Atmosphere.

NOTE: This section applies to NPS 3" ANSI 900/1500 and NPS 4" Multiports only.

Refer to the injection system drawing I-0240 on page 18. Recommended sealant is Sealweld D-1014 or equivalent.

1.The Multiport Flow Selector is shipped with the service valve (174) in the normally closed position.

2.To determine if the primary seal has failed, remove the vent plug (176) from the service valve and gradually open it. Any leakage occurring past the primary seal will drain out of the open service valve.

3.If more information is required, contact the factory.

(I-0320--.doc/13)

13

Image 13
Contents Multiport Flow Selector Table of Contents Minimum Tools Required Observe ALL Warning Decals and TagsIntroduction Multiport SpecificationsIIB Actuator Specifications Iiib Field Technician Commissioning Activities III Multiport InstallationHome Port Calibration I-0168/RD-00232 Section H Multiport Electronic Controller SET UPMultiport Assembly Multiport MaintenanceBody PlugBonnet Plug Seal Adjustment VII Actuator Assembly Multiport DisassemblyPedestal, Connector, Speed Reducer, and Motor 0320--.doc/12 Plug Seal Assembly Leaks Viii TroubleshootingActuator Does Not Align Plug 130 to Port Plug to Bonnet Stem Seal Leaks to AtmosphereIX Drawings 0320--.doc/15 0320--.doc/16 0320--.doc/17 0320--.doc/18 0320--.doc/19 Typical Multiport Seal Components 0320--.doc/21 Plug Seal Adjustment Tool in Plug Multiport Flow Selector Notes Baldor Motors Appendix 1 Motors0320--.doc/appendix 0320--.doc/appendix Elnor Motors 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix Pacific Scientific Motors 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix Morse Gearbox Appendix 2 Gear Reducers0320--.doc/appendix 0320--.doc/appendix Boston Gear Gearbox 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix 0320--.doc/appendix Baldor Gearbox