ETA Systems FC01-LQ manual ERR. Bargraph OUT of Range, ERR. Bargraph Zero ≥ FS, LS1 → F / LS2 → F

Page 42

 

 

Flow Meter FC01-LQ

ERR. BARGRAPH

OUT OF RANGE

 

(bar value outside measuring range)

ERR. BARGRAPH

ZERO FS

 

(bar initial value bar final value)

The menu can only be quitted after correction of the error(s). To do this, return to the beginning

of the configuration menu by pressing ▲ UP or DOWN and select the menu option with the incorrect entry for correction.

Caution!

If during the configuration data are affected which are accessible in the parameter selection menu, (which may be the case for the options Sensor Selection, Medium Selection and Limit Switch Assignment), the option “PARAMETERS” in the main menu will be flashing.

In this event it is imperative to branch into parameter selection menu to set the data in conformance with the desired application.

Example:

Changing the limit switch assignment from LS1 F / LS2 T to

 

LS1 F / LS2 F

Effects on

 

parameter data:

LS2 ON = 0.00

 

LS2 OFF = end of measuring range (depending on the medium selected)

Reason:

Changing the physical assignment of limit switch 2 will adjust its switch-on and

 

switch-off values to the new assignment (flow rate).

An overview of the configuration menu and a summary of the measuring ranges and menus available for the sensor type selected are shown on the following pages.

36

Configuration

Image 42
Contents Flow Meter FC01-LQ Flow Meter FC01-LQ Table of content Analogue output flow rate ANA OUT Flow Index Appendix IIIFlow Meter FC01-LQ Description Flow Meter FC01-LQ Calorimetric monitoring procedure Flow Meter FC01-LQ System description Signal outputs User interfacesTwo-channel physical isolation, relay change over contact Power supply FilterStainless steel 1.4571 / Aisi 316 Ti InstallationSelection of material Nickel-based alloy HastelloyApplication Flow Meter FC01-LQ Installation of the monitoring headsInstallation StyleSensoradapter TP Brass or Stainless steel 1.4571/AISI 316 TiBall valve BV-… Monitoring head CSF-11 with adjustable immersion depth MediumMounting instructions for monitoring head CSF-11 Caution Horizontal pipeline20 x D = nominal pipe diameter D 5 x D Electrical connection Locking setMechanical installation Rail-mounted version FC01-LQ-U1Surface mounted version FC01-LQ-FH-U1 Front panel mounted housing FC01-LQ-ST-U1 XTF Keyboard release XV Power supplySgnd XSKXAO - Analogue outputs Pin selection for analogue outputs option V1, V2, C1XSK Connection of calorimetric monitoring head type CSx XAS secondary current supplyFC01-LQ Circuit diagram FC01-LQ Version 24 V, transistor outputs NPN FC01-LQTypical circuit example Electronic signal processing figElectrical connection frequency output version FC01-LQ-U1T4 XAS XAOElectromechanical pulse counter fig Xasxao XAHOperating system Keypads M MODE, UP and DownMode Entry of numerals Menu pagingCalling a menu option Transfer of entriesOperation and main menu Switch-on performancePeak Value MIN Peak Value MAX Last Error Totalisator Measuring cycleBar graph indication Operating dataMeasured values TotalizerMIN Value Last error menu option Last ErrorPeak values menu option Peak Value MIN / Peak Value MAX MAX ValueMain menu Configuration menu option Configuration Selection of monitoring head menu option Sensor SelectMonitoring head data menu option Sensor Code Limit switch combinations menu option Limit Switches SelectionMedium temperature unit menu option TEMP. Unit Flow Meter FC01-LQ Flow rate unit menu option Flow UnitDisplay menu option Display Select Bar graph menu option Bargraph Zero =Example Flow Meter FC01-LQ Pipe diameter menu option Pipe Size Frequency output menu option Frequency OutputPulse / quantity totalizer unit selected Analogue output medium temperature menu option ANA OUT Temp Quitting the configuration menuLS1 → F / LS2 → F ERR. Bargraph OUT of RangeERR. Bargraph Zero ≥ FS LS2 on =Flow Meter FC01-LQ Configuration menu Configuration submenus Configuration submenus cont’d Yes Parameter selection menu option Parameters Measuring time menu option MEAS. TimeScaling factor menu option Flowscale Example for onError LS1 On = OFF Error LS1 OUT of RangeError LS2 OUT of Range Error LS2 On = OFFFlow Meter FC01-LQ Parameter selection menu Errors Test and diagnosisPriority group Flow Meter FC01-LQ Potential errors Priority groupFlow Meter FC01-LQ Power supply Technical dataElectrical characteristics Ambient conditionsAnalogue outputs Shield ungrounded apply on one side onlyVoltage output V2 10 V FS Signal outputsVoltage output V1 5 V FS Current output C1 20 mA FSResistive load Inductive load with safety circuit AC voltageTransistor outputs DC Voltage levelInductive load L 100 mH Capacitive load C 20 µFMonitoring head CSP- with sensor adapter type TP Flow Meter FC01-LQ Metrological dataFlow rate measurement Monitoring head CSFFailure diagram for water Temperature measurement Electronic control unit FC01-LQFlow Meter FC01-LQ Sensor interface FC01-LQ-ST AccessoriesFC01-LQ-FH CSP / CSFFlow Meter FC01-LQ Last Error Limit Switches LS1 OFF LS1 on LS2 OFF LS2 on IndexDisplay Select Peak Value MAX Peak Value MIN Pipe Size Sensor Code Sensor SelectTEMP. Unit Totalisator Normal duty Flow Meter FC01-LQ Appendix 2 Menu structure of the FC01-LQ operator dialog

FC01-LQ specifications

ETA Systems FC01-LQ is a sophisticated compact computer designed for various applications in automation, data processing, and embedded systems. Its robust architecture and energy-efficient design make it suitable for both industrial and consumer uses. The FC01-LQ stands out in a crowded field of compact computing devices due to its unique features and advanced technologies.

One of the most notable characteristics of the ETA Systems FC01-LQ is its low power consumption, which is crucial in applications where energy efficiency is paramount. This system leverages advanced power management technologies, allowing it to operate effectively while consuming minimal energy. This is particularly beneficial in environments where maintenance and energy costs are critical factors.

In terms of performance, the FC01-LQ is equipped with a powerful processor that ensures smooth operation and reliable performance across various tasks. It supports multiple processing cores, allowing for efficient multitasking capabilities. This makes it ideal for applications that require handling multiple data streams or executing several processes simultaneously.

Another key feature of the ETA Systems FC01-LQ is its extensive connectivity options. With multiple USB ports, Ethernet interfaces, and serial connection capabilities, this system can easily integrate into existing networks and work alongside other devices. This flexibility makes it an excellent choice for automation systems, IoT devices, and other networked applications.

The compact form factor of the FC01-LQ is another significant advantage. Its small size allows it to fit into tight spaces, making it perfect for embedded systems where real estate is limited. Despite its compact dimensions, it does not compromise on performance, delivering capabilities typically found in larger computer systems.

Built for durability and reliability, the FC01-LQ is designed to withstand harsh environmental conditions. It features a rugged casing that protects it from dust, moisture, and various temperature extremes. This durability ensures that it can operate effectively in industrial settings where equipment may be exposed to challenging conditions.

In summary, ETA Systems FC01-LQ is a powerful, energy-efficient, and compact computer solution that integrates advanced features and technologies. Its versatility makes it suitable for a wide range of applications, from industrial automation to consumer electronics. The combination of performance, adaptability, and durability positions the FC01-LQ as a go-to choice for those seeking a reliable embedded computing solution.