OPERATION

1. DISPLAY BACKLIGHT

Press the

.

.

.

^ / key to choose the desired display backlight mode:

“Auto Backlight” mode. When the weight is over 10 divisions or any key is pressed, the display backlight will be switched on. When the weight returns to zero or the weight on platform is less than 10 divisions, the display backlight will switch off after 5 seconds.

Display backlight is on all the time. Display backlight is off.

2. ZERO

Press the

0

key to re-zero the display with no load on the weigh pan. When zero is set,

the (à0ß) symbol will be displayed.

3. WEIGHING MODE

(1). Units Selection

1. Press the

UNITS

key in the weighing mode to choose the desired weighing unit and the

display will show the “kg” or “lb” symbol on the top right of the LCD display.

2. The unit status will be memorized when turning the machine off.

(2). Totalising

1. The scale allows the next totalising operation, even when the weight value does not return

back to zero. The

M+

key is functional, when the weight value changes by more

than 10 d. The scale will store the totalised weight value after the weight is stable.

2.The scale can totalise positive or negative weight but not both at the same time. The totalised weight store must be reset to zero before it is possible to select positive or negative totalising mode.

V1.1

8

ZSME300000011

Image 10
Contents Digital High Precision Weighing Scales Page Table of Contents Relay Output Before Using the Scale Preparing to USE the ScaleFeatures IntroductionPower Consumption SpecificationsLOW Battery Warning LCD Display Symbols LOWKeyboard Function UnitsDisplay Backlight Weighing ModeOperation ZeroII. Recall Totalised Weight Values Weight TotalisingIII. Clear Totalised Weight Values II. Recall the semi-auto tare value Deduction of the Container WeightWeight of the container is unknown Tare III. Clear the semi-auto tareRecall the pre-set tare value IV. The weight of the container is known Pre-set tareVI. Clear the pre-set tare value Buzzer Setting Check WeighingClear the check weighing settings IV. Recall the check weighing settingIII. High/OK/Low indications Counting Function SamplingConfiguration Settings CHECK-WEIGHING Configuration Actiondisplay DescriptionRS-232 Setting Exit Configuration Settings RS-232 25 Pin ‘D’ type Pin Description RS-232 and Relay Output RS-232 or Serial Printer OutputRS-232 Interface Format Data Format Transmission example+100.0 kg Key to Relay Pin Description Relay OutputRelay Output Connection IllustrationPower Source Illustration Connection Setting