Sega 999-0858 owner manual Emergency Call Ambulance

Page 3

ROM CHANGE INSTRUCTIONS

MA_ADD

 

SEGA Service Department

http://www.seuservice.com

 

45133 Industrial Drive

Phone: 415.701.6580

 

Fremont, Ca. 94538

Fax: 415.701.6594

 

EMERGENCY CALL AMBULANCE

Before starting work be sure to turn power off. Failure to observe this can cause electric shock and short circuit hazards.

Use care so as not to damage wirings. Damaged wirings can cause electric shock or short circuit accidents.

This work should be performed by the Locations Maintenance Man or Serviceman. Performing work by those who do not have technical expertise can cause electric shock accident, or damage to the Game Board

KIT INSTALLATION INSTRUCTIONS:

1.) Turn power off & Disconnect all plugs from the Game Board Cage.

2.) Remove Cage and open Case Lid.

3.) Remove (12) phillips screws and remove the PCB from Cage.

4.) Remove (4) phillips screws and nuts that secure Security Board to CPU Board. Remove Security Board.

5.) Install new Security Board and secure with the (4) philips screws previously removed; DO NOT OVER TIGHTEN!

6.) Remove each of the (41) E-Proms and Mask Roms from the Rom Board. Be careful not to scratch the Board or break sockets.

7.) Install new E-Proms and Mask Roms. Be careful not to damage IC by static electricity. Be careful not to bend pins while inserting E-Proms and Mask Roms.

8.) Re-install Game Board into cage, then replace cage into cabinet. Reconnect all connectors.

9.) Power On Game and test for proper operation. Set all game options.

Please see diagrams on the following page for E-PROM and ROM layout.

If you have any questions please contact the SEGA Service Department at the numbers given above.

Image 3
Contents Emergency Call Ambulance Warranty Emergency Call Ambulance NEW Emergency Call Ambulance E-PROM and Mask ROM Layout Page Composition of Game Board game board not included Visit OUR Website