Aiphone 83873900 0602 E Operations on NHX-50M At NHX-50M, Receiving a Routine Call Bedside

Page 28

5 OPERATIONS on NHX-50M

At NHX-50M

Directory

Speaker

Sub call-in LED

 

Sub Selector button

Handset

 

Power on LED

 

Mic

Attendance LED

 

TONE-OFF button

OFF

TALK button

button

 

Receiving a Routine Call (Bedside)

At NHX-50M

When a Bedside sub station presses CALL button;

1.Single chime tone rings on NHX-50M every 6 seconds, and a call-in LED blinks slowly every 2 seconds.

2.Press TONE-OFF button to silence tone. The LED above is lit.

3.Go to the Sub station. Press CANCEL button to reset.

For communication;

1.Simply lift handset and communicate (voiceactuated). Or press TALK button and communicate.

2.At conclusion, replace handset, or press OFF button.

At site

At Zone light;

A corresponding zone lamp is steadily lit.

At corridor lamp;

White lamp is steadily lit.

At Sub station;

While NHX-50M is ringing, red CALL LED is lit, and stays on even after TONE-OFF is pressed.

OR When NHX-50M replies, green ‘TALK’ LED is lit. ‘TALK’ LED goes out when communication is finished.

Receiving a Bathroom Pullcord Call (or call from NHR-3TS sub)

At NHX-50M

At site

 

 

When a cord is pulled at Bathroom;

1.Single chime tone rings on NHX-50M every 1.8 seconds, together with LED double blinking.

2.Press TONE-OFF button to mute. The LED above is lit for attendance.

3.At Sub station, attendant unlocks CALL switch to reset the call.

At Zone light;

Light will indicate which zone has a call placed.

At corridor lamp;

Red light blinks.

At Sub station;

Red CALL LED is lit.

* Communication is not available from Bathroom.

Receiving a Cord-Out Trouble Call

At NHX-50M

At site

 

 

When a plug has been pulled out of jack;

1.Single chime tone rings on NHX-50M every 0.5 seconds, and a call-in LED blinks fast.

2.Press TONE-OFF button to silence tone. The attendance LED is lit above.

3.At the Sub station, attendant may plug the pullcord back into jack to reset the call.

At Zone light;

Light will indicate which zone has a call placed.

At Corridor lamp;

White light blinks.

At Sub station;

Red CALL LED is lit. When the pullcord is plugged in, all lights are reset.

*To communicate, either lift handset or press TALK button to establish channel.

– 28 –

Image 28
Contents NHX System Contents Precautions on Installation & Wiring PrecautionsGeneral Precautions MarkingsSystem Outline & Components  System OutlineSystem Outline & Components  Components Available NHR-DP  NHX-50M Names & FeaturesNHX-50M Names & Features  NHX-30GNHX-30G  NH-1SA/A NHX-80X  PS-24E  PS-2420Names & Features  NHR-3TS  NHR-SP System Features  System capabilitiesInstallation & Wiring Installation & Wiring Example Sub station # ChartNHX-50M master station Sub stations Checking Status of Sub stations on NHX-50M Testing  Initializing NHX-80X for Sub stationsM2 GND S2 GNDPreset volume controls  Terminal block layout NHX-50MNH-1SA/A NH-1SA NH-2SA/A NH-2SA NHR-3TS NHR-SPWiring Diagrams NHX-80X CCU to NHX-50M, NHX-30G & Duty stationPower supply for Zone lights  Schematic diagram of Zone light NHR-3A-4PS-24E or PS-2420 power supply Zone lightsNHX-80X CCU to Sub stations Permitted wiring distance to Sub stationsNH-2SA or Bathroom call sub station NHR-3TS Bedside sub stations w/Corridor lamp & Bathroom PullcordBedside Sub stations NH-1SA/A, NH-1SA NH-2SA/A or NH-2SA Multi-Station Patient Room Applications Right row of Bedside Subs Mounting To open the front cover Mounting NHX-80X inside Electrical Enclosure 18-1/8 H13-3/8 W3-7/8 D 460H340W98D mm Mounting NHX-50M master station Mounting Assembling two Consoles NHX-50M & NHX-30G Sub station back case dimensions in recess  Sub trunk line cablingCorridor lamp for bedside sub NHR-3TS Sub station NHR-4A Operations on NHX-50M At NHX-50M Receiving a Routine Call BedsideReceiving a Bathroom Pullcord Call or call from NHR-3TS sub Receiving a Cord-Out Trouble CallAt NHX-50M Placing Call Volume AdjustmentsOperations on NHX-50M Technical Precautions TemperaturesDuty Station Operation Call HoldingTechnical Precautions Reset switchSpecifications NHX-80X

83873900 0602 E specifications

The Aiphone 83873900 0602 E is a sophisticated intercom system designed to enhance communication and security in residential and commercial environments. This model combines advanced technologies and user-friendly features, making it an ideal choice for those seeking reliable intercom solutions.

One of the main features of the Aiphone 83873900 0602 E is its dual-channel capability, allowing users to communicate over two separate lines. This feature is particularly useful in larger homes or office complexes where managing multiple conversations is essential. The intercom system is equipped with clear audio output, ensuring that conversations are crisp and easy to understand, even in noisy environments.

A key characteristic of the Aiphone 83873900 0602 E is its robust build quality. Constructed with durable materials, this intercom can withstand the rigors of daily use while providing a sleek and modern aesthetic. The design ensures that it blends seamlessly into a variety of settings, whether placed in a home, a retail space, or an office.

Technologically, the Aiphone 83873900 0602 E employs innovative digital signal processing which enhances audio clarity and minimizes background noise during conversations. It also features a user-friendly interface with intuitive controls, making it simple for users of all ages to operate. The system integrates easily with existing wiring, reducing installation complexity and cost.

Another notable feature of the Aiphone 83873900 0602 E is its expandability. Users can connect multiple units together, allowing for customized setups that cater to specific needs. This scalability makes it a versatile option for both small residences and larger enterprises.

The device is also equipped with visual indicators that alert users to incoming calls, ensuring that important communications are never missed. This feature is particularly beneficial in busy environments where distractions may lead to missed messages.

In summary, the Aiphone 83873900 0602 E stands out in the intercom market with its dual-channel capability, durable construction, advanced digital technologies, and excellent expandability. Whether for personal use or a professional setting, this intercom system delivers reliable performance, modern functionality, and ease of use, making it a worthy investment for enhancing communication and security. Choosing the Aiphone 83873900 0602 E means opting for a product that embodies convenience, quality, and innovation.