Aiphone 83873900 0602 E Technical Precautions, Temperatures, Duty Station Operation, Call Holding

Page 30

5.OPERATIONS on NHX-50M

Call tone & light annunciation

 

 

 

(*) Sound & LED time is approximate.

 

Type of calling

Call tone

Light

 

 

 

At NHX-50M Master station

 

 

• Receiving

Routine call

Single chime, every 6 sec.

Blinking, every 2 sec.

 

Bathroom call (urgent)

Single chime, every 2 sec.

Double blinking, every 1.8 sec.

 

Cord-out trouble call

Single chime, every 0.5 sec.

Blinking fast, every 0.4 sec.

Line-off trouble

Bedside sub from Trunk

Slow buzzer, intermittent

Lit 0.2 sec., every 2 sec.

 

Duty station from NHX-80X

Faster buzzer, intermittent

No light

• While talking

 

Call tone (as above)

Call-in LED steadily lit

 

 

At NH-1SA/A, NH-1SA, NH-2SA/A or NH-2SA Bedside Sub station

 

• Placing

Routine call

CALL steadily lit

 

Bathroom call (urgent)

Not lit

 

 

 

CALL lit on Pullcord switch

 

Cord-out trouble call

CALL steadily lit.

• While talking

 

CALL is off, and TALK is on.

• When master calls in

 

Pre-tone

TALK is on

 

 

 

At NHR-4A Room Corridor lamp (white/red)

 

 

• When Sub placed a call

Routine call

White steadily lit

 

Bathroom call (urgent)

Red blinking

 

Cord-out trouble call

White blinking

 

While talking

Not lit

 

 

 

 

At NHR-3A-4 Zone light

 

 

 

• When Sub placed

Routine call

1 ~ 4 lamp turns on for any call from

 

Urgent call

Bedside sub or NHR-3TS.

 

Cord-out trouble call

 

 

 

At NHR-3TS sub station (w/corridor lamp) in Common area or Hallway

 

Placing

Bathroom call (urgent)

Red blinking on NHR-3TS

 

Staff call (urgent)

White blinking on NHR-3TS

 

 

 

 

At NHR-SP Duty station

 

 

 

• When Master received

Routine call

Single chime, every 6 sec.

CALL blinking, every 2 sec.

 

Urgent call

Single chime, every 2 sec.

CALL double blinking, every 1.8 sec.

 

Cord-out trouble call

Single chime, every 0.5 sec.

CALL blinking fast,every 0.4 sec.

While Master talking

 

Not lit

 

 

 

 

Calling from NHX-50M

When NHX-50M has called a bedside Sub station, no light turns on on the corridor lamp, zone light and sub station except TALK LED lit green on the sub station.

6TECHNICAL PRECAUTIONS

Temperatures

NHX-80X and NHX-50M are rated to operate at temperatures 10˚C~49˚C(50˚F~120˚F).

Duty Station Operation

At NHR-SP, sub station call-in is annunciated by tone & LED, which are the same as on NHX-50M.

The TONE-OFF button silences tone, but CALL LED remains lit. When the NHX-50M begins communication, both tone and LED are deactivated.

90 seconds after the call tone is muted, it will ring again. Press TONE-OFF button, and it will no longer ring (tone will resume when another sub calls).

Call Holding

Every Routine call is held electronically at bedside sub station, and will be automatically connected when handset is lifted or TALK button is pressed at the NHX-50M. To reset the call, press CANCEL button on the Sub station. When a Bathroom call & Cord-out trouble call is activated, the LED will remain on even after the NHX-50M has answered. The call must be reset at the calling site.

– 30 –

Image 30
Contents NHX System Contents General Precautions Precautions on Installation & WiringPrecautions MarkingsSystem Outline & Components  System OutlineSystem Outline & Components  Components Available NHR-DP Names & Features  NHX-50MNHX-50M NHX-30G Names & Features NHX-30G  NH-1SA/A NHX-80X  PS-24E  PS-2420Names & Features  NHR-3TS  NHR-SP System Features  System capabilitiesInstallation & Wiring NHX-50M master station Installation & WiringExample Sub station # Chart Sub stations Checking Status of Sub stations on NHX-50M Testing  Initializing NHX-80X for Sub stationsM2 GND S2 GNDNH-1SA/A NH-1SA NH-2SA/A NH-2SA NHR-3TS Preset volume controls Terminal block layout NHX-50M NHR-SPWiring Diagrams NHX-80X CCU to NHX-50M, NHX-30G & Duty stationPS-24E or PS-2420 power supply Power supply for Zone lights Schematic diagram of Zone light NHR-3A-4 Zone lightsPermitted wiring distance to Sub stations NHX-80X CCU to Sub stationsNH-2SA or Bedside sub stations w/Corridor lamp & Bathroom Pullcord Bathroom call sub station NHR-3TSBedside Sub stations NH-1SA/A, NH-1SA NH-2SA/A or NH-2SA Multi-Station Patient Room Applications Right row of Bedside Subs  Mounting NHX-80X inside Electrical Enclosure MountingTo open the front cover 18-1/8 H13-3/8 W3-7/8 D 460H340W98D mmMounting  Mounting NHX-50M master station Assembling two Consoles NHX-50M & NHX-30G Corridor lamp for bedside sub Sub station back case dimensions in recess Sub trunk line cabling NHR-3TS Sub station NHR-4A Receiving a Bathroom Pullcord Call or call from NHR-3TS sub Operations on NHX-50M At NHX-50MReceiving a Routine Call Bedside Receiving a Cord-Out Trouble CallVolume Adjustments At NHX-50M Placing CallOperations on NHX-50M Duty Station Operation Technical PrecautionsTemperatures Call HoldingTechnical Precautions Reset switchSpecifications NHX-80X

83873900 0602 E specifications

The Aiphone 83873900 0602 E is a sophisticated intercom system designed to enhance communication and security in residential and commercial environments. This model combines advanced technologies and user-friendly features, making it an ideal choice for those seeking reliable intercom solutions.

One of the main features of the Aiphone 83873900 0602 E is its dual-channel capability, allowing users to communicate over two separate lines. This feature is particularly useful in larger homes or office complexes where managing multiple conversations is essential. The intercom system is equipped with clear audio output, ensuring that conversations are crisp and easy to understand, even in noisy environments.

A key characteristic of the Aiphone 83873900 0602 E is its robust build quality. Constructed with durable materials, this intercom can withstand the rigors of daily use while providing a sleek and modern aesthetic. The design ensures that it blends seamlessly into a variety of settings, whether placed in a home, a retail space, or an office.

Technologically, the Aiphone 83873900 0602 E employs innovative digital signal processing which enhances audio clarity and minimizes background noise during conversations. It also features a user-friendly interface with intuitive controls, making it simple for users of all ages to operate. The system integrates easily with existing wiring, reducing installation complexity and cost.

Another notable feature of the Aiphone 83873900 0602 E is its expandability. Users can connect multiple units together, allowing for customized setups that cater to specific needs. This scalability makes it a versatile option for both small residences and larger enterprises.

The device is also equipped with visual indicators that alert users to incoming calls, ensuring that important communications are never missed. This feature is particularly beneficial in busy environments where distractions may lead to missed messages.

In summary, the Aiphone 83873900 0602 E stands out in the intercom market with its dual-channel capability, durable construction, advanced digital technologies, and excellent expandability. Whether for personal use or a professional setting, this intercom system delivers reliable performance, modern functionality, and ease of use, making it a worthy investment for enhancing communication and security. Choosing the Aiphone 83873900 0602 E means opting for a product that embodies convenience, quality, and innovation.