Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 31312
,IFT /PERATING )NSTRUCTIONS
O
Q
S
U
UP
Switch
UP
Switch
TO LOAD PASSENGER:
1.Load passenger onto platform fac- ing outward and lock wheelchair brakes. See Photos Q and R.
Note: Outer barrier must be fully unfolded until entire wheelchair has crossed the barrier. See Pho- tos O and P.
2. Press UP switch until platform raises just above ground level. Release switch.
3.If necessary, press the switch arm LEVEL switch until platform is level.
4. Press UP switch until platform stops (reaches floor level) and inboard locator unfolds (see Photo W). Re- lease switch.
P
R
LEVEL Switch
T
V
Inboard Locator
(unfolded)
W
Y
AA
CC
5.Unlock wheelchair brakes and unload passenger from platform.
TO STOW PLATFORM:
1. Press STOW switch until platform stops (fully stowed - vertical). Re- lease switch.
2.Press STOW switch (Photo Y) until platform sections close (rotate) to locked position. See Photos
TO CLOSE DOOR(S):
Power Door Operator(s):
Press the STOW switch until door(s) are fully closed. Release switch.
Manual Door(s):
Manually close door(s) fully.
X
Z
BB
DD