Chauvet GVC, RGY, RVM user manual Master/Slave Mode, Laser Sky Mode

Page 16

Laser Sky Mode

To enable the Laser Sky Mode, follow the instructions below:

1)Connect this product to a suitable power outlet.

2)Turn this product on.

3)Press <MENU> repeatedly until one of the following menu options appear on the display: LS1, LS2, LS3.

4)Press <ENT>.

Never connect a fixture that is operating in Static, Automatic, or Sound mode to a DMX string that is being controlled by a DMX controller because it may interfere with the signal from the controller.

Master/Slave Mode

This mode allows a single Scorpion™ RVM/RGY/GVC unit (the “master”) to control the actions of one or more Scorpion™ RVM/RGY/GVC units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in either Automatic or Sound mode, while the slave units will be set to operate in Slave Mode. Once set and connected, the slave units will operate in unison with the master unit.

Configure the units as indicated below.

Slave units:

1)Press <MENU> repeatedly until SLA shows on the display.

2)Press <ENT> to accept.

3)Connect the DMX input of the first slave unit to the DMX output of the master unit

4)Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit.

5)Finish setting and connecting all the slave units.

Master unit:

1)Set the master unit to operate in either Automatic, Laser Sky, or Sound mode, as previously indicated.

2)Make the master unit the first unit in the DMX daisy chain.

Wait until all the slave units are configured and connected before connecting the master unit to the DMX daisy chain.

Never connect a DMX controller to a DMX string configured for Master/Slave operation because it may interfere with the signals from the master unit.

Do not connect more than 31 slave units to the master unit.

Page 16 of 24

Scorpion™ RVM/RGY/GVC User Manual (Rev. 01e)

Image 16
Contents Page Table of Contents Before YOU Begin Safety Notes Non Interlocked Housing WarningLaser Safety Notes Stop and Read ALL the Laser Safety Notes belowLaser Safety Labels Laser Emission Data Scorpion RVMScorpion GVC Scorpion RGYIntroduction Product OverviewProduct Dimensions Proper Usage MetersAC Power SetupPower Linking Orientation MountingRigging Control Panel Operation OperationMenu Map LS1 DMX Mode ConfigurationStandalone Modes Master/Slave Mode Laser Sky ModeDMX Channel Assignments and Values Random AutoDMX Ch.2 Pattern Selection General Maintenance Technical InformationGeneral Troubleshooting Symptom Possible Cause Possible ActionClaims Returns ProcedureContact Information Starting Address DMX PrimerFixture Linking Daisy Chain DMX Cabling DMX ConnectorsTo 5-PinConversion Table Technical Specifications Power