Item

AX70

 

 

 

AX70+U-PHOTO/U-PHOTO20/80/U-AFPHOTO

 

Type

Y-shape frame with built-in transmitted/incident light vertical illuminator

 

 

Optical system

UIS optical system (infinity-corrected/compensation-free)

 

 

 

 

12V100W halogen (2,000 hours long-life type), pre centered

 

stand

Transmitted illumination

Mechanical field diaphragm (motorized field diaphragm unit attachable)

 

Six built-in manual filters (ND1.5, ND3, ND6, ND12, IF550, LBD; motorized filter changer attachable)

 

 

 

One optional external filter can be user-installed (manual operation)

 

Microscope

Focus

Universal vertical illuminator, 12V100W halogen/Hg100W/Xe75W applicable, optical devices detachable, motorized mirror unit changer, excitation light

Vertical stage movement by manual roller guide, stage travel range: 25mm. Coaxial coarse and fine focus handle, minimum fine focus adjustment

 

Incident illumination

shutter (interlocking operation when changing an objective/observation method). Max. three filter sliders (six filters) attachable (when using AX-RFCH)

 

Illumination adjustment

1-12V (adjustable in units of 0.1V by the jog dial), light preset switch, transmitted/incident halogen illumination changeover switch

 

 

graduation: 1∝ m increments, stroke per rotation: 0.1mm (fine), 15mm (coarse). Sensitivity: less than 1∝ m

 

 

Main switch located at power supply (U-PS), light adjustment dial: right front, field control knob: left front, sub-main switch, changeover switch for

 

Operation control position

transmitted/incident illumination, light preset switch: right wing of frame, hand switch attached (objectives direct changeover, objectives recall, mirror unit

 

 

direct changeover. Incident excitation shutter on/off, lamp off possible)

 

 

Power supply (U-PS)

100/120/220/230/240 V automatic changeover, main switch attached

 

 

 

(when using U-SWTR-2)

 

 

 

 

 

 

 

F.N. 26.5 (super widefield), adjustable

 

 

 

 

 

Observation tube

interpupillary distance range: 50-76mm,

 

 

Integrated in photomicrographic unit

 

inclined 24゜, right eyepiece sleeve correction

 

 

 

 

mechanism, photo focusing can be attached,

 

 

 

 

 

 

reticle/photo mask rotation stop included,

 

 

 

 

 

 

(erect image, U-SWETR attachable)

 

 

 

 

 

Revolving nosepiece

 

 

 

Motorized sextuple nosepiece, motorized quintuple nosepiece for reflected darkfield observation, various manual nosepieces attachable

 

Stage

Stroke range: 52×76mm (with vernier), max two sliders can be inserted, torque adjustable, selectable from right handle or left handle, knob position (tip):

 

57mm from desk top

 

 

 

 

 

 

 

 

 

 

 

 

 

Condenser holder

Vertical stroke range: 25mm (when using AX-UCDM: 10mm), centering adjustment function (AX-UCDM: standard feature), both sides condenser

 

movement control knobs, (AX-UCDM: motorized)

 

 

 

 

 

 

 

 

 

Observation tube

—

 

 

F.N. 26.5 (super widefield), adjustable interpupillary distance range: 50-76mm, inclined 24゜,

 

 

 

magnification [(direct optical path: 1×, optical path through zoom: 1-2× (zoom)]

 

 

 

 

 

 

Camera

—

 

 

Two 35mm cameras, one large-format camera, one video camera (all can be attached at the same

 

 

 

time); two video cameras can be mounted by connecting U-TVL to the large-format port; selectable by

 

 

 

 

 

U-MCB

 

 

 

 

 

 

 

• U-PHOTO/U-AFPHOTO

 

 

 

 

 

 

[Direct optical path]

 

 

 

 

 

 

BI : video camera (direct) = 100:0/0:100

 

 

 

 

 

 

[Peripheral optical path] (all light goes to camera optical path during exposure)

 

 

 

 

 

BI : video camera (direct) : video camera 2 : photometry

 

 

 

 

 

= 100:0:0:0 / 0:100:0:0 / 0:0:100:0 / 20:0:0:80 / 0:20:0:80

 

 

 

 

 

(video camera 2 is mounted to the large-format port via U-TVL.)

 

 

 

 

 

※ When using auto focus function of U-AFPHOTO:

 

 

 

 

 

BI : video camera (direct) : video camera 2 : photometry : AF sensor

 

 

 

 

 

= 50:0:0:0:50 / 0:50:0:0:50 / 0:0:50:0:50 / 10:0:0:80:10 / 0:10:0:80:10

 

 

 

 

 

[Camera optical path]

 

 

Optical path changeover

—

 

 

35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:10:0

 

 

 

※ When using video camera 2

 

 

 

 

 

 

35mm left : 35mm right = 100:0 / 0:100

 

unit

 

 

 

 

• U-PHOTO20/80

 

 

 

 

 

[Direct optical path]

 

Photomicrography

 

 

 

 

BI : video camera (direct) = 100:0 / 0:100

 

 

 

 

 

[Peripheral optical path] (80% of all light goes to camera optical path during exposure)

 

 

 

 

 

BI : video camera (direct): video camera 2 : photometry

 

 

 

 

 

= 20:0:80:0 / 100:0:0:0 / 0:100:0:0 / 20:0:0:80 / 0:20:0:80

 

 

 

 

 

(video camera 2 is mounted to large-format port via U-TVL)

 

 

 

 

 

[Camera optical path]

 

 

 

 

 

 

35mm left : large-format : 35mm right = 100:0:0 / 0:100:0 / 0:0:100

 

 

 

 

 

※ When using video camera 2

 

 

 

 

 

 

35mm left : 35mm right = 100:0 / 0:100

 

 

Photo magnification

—

 

 

35mm camera: 2.5x-5x, large-format camera: 7.5x-15x

 

Zoom

—

 

 

Motorized control by jog dial or fixed magnification switch of U-MCB. Zoom ratio: 2×

 

Focusing telescope

—

 

 

Manual insertion, magnification ratio: 3.4× (besides U-AFPHOTO)

 

Photo frame reticle

—

 

 

Manual insertion, bright frame operation (red/yellow), illumination adjustment (seven levels)

 

Shutter

—

 

 

Pulse-control electromagnetic shutter, shutter speed: max. 1/125 sec.

 

Photometry

—

 

 

2D image analysis memory mode by the CCD. 0.1% spot measurement, 1% spot measurement, 30%

 

 

 

average measurement switchable. Flexible spot measurement area, spot color switchable (red/yellow)

 

 

 

 

 

 

 

 

 

Five exposure modes: Auto mode, FL Auto mode, Super FL Auto mode, Manual mode, time mode.

 

Photometry conditions

—

 

 

Auto exposure range: 1/125 sec.-68min. ISO: 3-25,600 (automatic setting by DX method, manual

 

 

 

setting also possible). 13-step exposure control (0.25-4, every 1/3 step). Auto bracketing function,

 

 

 

 

 

eight-level reciprocity failure correction, multi-exposure, AE lock, exposure time recall,, data/scale

 

 

 

 

 

imprinting function (by imprinting unit)

 

 

 

 

 

 

35mm (PM-C35DX): auto loading/wind/rewind and automatic film detection, data imprinting unit can be

 

Camera back

—

 

 

attached, automatic setting of the ISO value by the DX code. Frame counting number is retained for

 

 

 

data back-up. Data imprinting unit (PM-DI-35): backlit exchange type

 

 

 

 

 

 

 

 

 

 

Large-format camera back (attached to U-DLF); Polaroid (PM-CP-3)

 

Multi-control box

 

 

 

Operation by transmitted touch panel and jog dial sheet switch. Graphics indicated on plasma display.

 

—

 

 

Centralized control of mentioned photomicrography conditions and all motorized parts are possible.

 

(U-MCB)

 

 

Memory card function: can register, recall, delete, print the information of photometry and observation.

 

 

 

 

 

 

 

 

 

External interface function: selectable from RS232C, GPIB or printer interface (optional)

 

 

 

 

 

Optical path difference based contrast system. Operation modes: real-time mode and one-shot mode

 

Auto focus

—

 

 

(switchable). Applicable magnifications: 1.25×-100×. Applicable condensers: AX-UCDM, U-UCDB,

 

(on U-AFPHOTO only)

 

 

U-AAC, U-ULC-2. Applicable microscopic observation: brightfield/darkfield, Nomarski DIC, polarized

 

 

 

 

 

 

 

 

 

light (both transmitted and incident light), fluorescence (incident light only)

 

Eyepiece

10x, F.N. 26.5 (super widefield of view)

 

 

 

 

 

Conform to ISO (*1)

PLAPO set: PLAPO2×

UPLAPO set: PLAPO2×

UPLAFL set: PLAPO2×

 

 

 

UPLAPO4×

UPLAPO4×

UPLAFL4×

 

Objectives

 

UPLAPO10×

UPLAPO10×

UPLAFL10×

 

 

 

UPLAPO20×

UPLAPO20×

UPLAFL20×

 

 

 

PLAPO40×

UPLAPO40×

UPLAFL40×

 

 

 

PLAPO100×O

UPLAPO100×O

UPLAFL100×O

 

 

Universal motorized condenser for AX (AX-UCDM): N.A. 0.16-0.9 (N.A. 0.16-1.4 with change of top lenses), objectives (1.25×-100×). Turret, aperture

 

 

diaphragm, top lens changeover polarizing plate attachment insertion: all motorized. Applicable for transmitted brightfield, transmitted darkfield, transmitted

 

Condensers

phase-contrast, transmitted Nomarski DIC, transmitted simple polarizing observations.

 

 

Swing-out Achromat (U-SC): N.A. 0.16-0.9, objectives (2×-100×). Achromat/Aplanat (U-AAC): N.A. 1.4, objectives (10×-100×). Universal (U-UCDB):

 

 

 

 

N.A. 0.2-0.9 , objectives (2×-100×). Phase-contrast darkfield (U-PCD): N.A. 1.25, objectives (10×-100×). For super low magnification (U-ULC-2): N.A.

 

 

0.16, objectives (1.25×-4×). Darkfield (dry): N.A. 0.8-0.92, objectives (10×-40×). Darkfield (oil): N.A. 1.20-1.40, objectives (10×-100×)

(*1) Conform to ISO9345-1, ISO8038.

22

Image 23
Contents AX70 Referenc for future mi Ce standard icroscopes AX70 + Universal Photo System AX70 Olympus UIS optics New standard of excellence Simple modification of microscopic systems Ideal resolution and contrastWorld Class Optics Aberration-free image even with added attachmentsMaximum quality for Various microscopy applications Resolution Contrast Imaging Page Photoactivation of caged fluorescein Illumination VersatilityPage Heat-resistant light source structure High StabilityFrame stability the basis of system flexibility Maximum operator comfort at all times Improved operational ease for enhanced manipulation Comfortable OperationAutomation facilitates research microscopy Computer-based control system Automatic OperationFlexible moving spot measurement Super FL Auto mode for automatic exposure controlSophisticated photo and video documentation systems Photo Universal Photo SystemFully automatic photomicrography via multi-control box Research DocumentationWay camera light path Observation comparison without and with AX-REXBA Optical center adjuster AX-OCA AccessoriesVideo camera adapters MPH multi-port headObservation tubes PM30 automatic photomicrography systemAX70 specifications ISO9001 ISO14001