Cooper Lighting P4PE-X/TE specifications Ordering Information, Shipping Information

Page 2

PHOTOMETRICS

2HBG

 

2HBG-632

Candela

 

 

 

(2) Electronic Ballasts

 

 

 

 

 

(6) F32T8/TL835

Angle

Along II

45°

Across

 

lamps

0

4712

4712

4712

 

5

4701

4666

4675

 

3000 lumens

 

10

4637

4691

4905

 

Spacing criterion:

15

4529

4898

5448

 

(II) 1.2 x mounting

20

4377

5225

5702

 

25

4182

5345

5543

 

height, ( ) 1.4 x

30

3940

5249

4951

mounting height

35

3658

4835

4926

 

Efficiency 83.4%

40

3341

4206

3576

 

45

2991

3554

3029

 

Test Report:

 

50

2615

2865

2759

 

2HBG632.IES

55

2217

2323

2430

 

LER =81

60

1804

1996

2234

 

Yearly Cost of 1000

65

1389

1644

2248

 

70

990

1495

1993

 

lumens, 3000 hrs at

75

626

1286

1567

 

.08 KWH = $2.98

80

319

832

740

 

 

85

85

172

81

 

 

90

0

0

0

2HBG-654T5

(3) Electronic Ballasts

(6)F54T5/841HO lamps

4400 lumens

Spacing criterion:

(II)1.2 x mounting height, () 1.1 x mounting height Efficiency 73.5%

Test Report: 2HBG654T5.IES

LER =63

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.83

Candela

Angle

Along II

45°

Across

 

0

8439

8439

8439

 

 

5

8404

8519

8622

 

 

10

8289

8683

8905

 

 

15

8092

8740

8905

 

 

20

7819

8587

8396

 

 

25

7473

8150

7205

 

 

30

7048

7258

5694

 

 

35

6550

6095

4381

 

 

40

5978

4755

3520

 

 

45

5335

3616

3031

 

 

50

4640

2835

2535

 

 

55

3909

2324

2239

 

 

60

3157

1829

2296

 

 

65

2411

1567

2296

 

 

70

1692

1536

1764

 

 

75

1042

1167

1297

 

 

80

500

669

602

 

 

85

100

135

22

 

 

90

0

0

0

 

 

C o effi c i e n t s of Utilization

 

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

99

99

99

99

97

97

97

97

93

93

93

89

89

89

85

85

85

83

 

1

 

91

87

83

80

88

85

82

79

81

79

76

78

76

74

75

73

72

70

 

2

 

82

76

70

65

80

74

69

64

71

67

63

68

65

61

66

63

60

58

 

3

 

75

66

59

54

73

65

59

54

62

57

53

60

56

52

58

54

51

49

 

4

 

69

59

51

46

67

58

51

45

56

50

45

54

48

44

52

47

44

42

 

5

 

63

53

45

39

62

52

45

39

50

44

39

48

43

38

47

42

38

36

 

6

 

58

47

40

34

57

47

39

34

45

39

34

44

38

34

42

37

33

32

 

7

 

54

43

36

30

53

42

35

30

41

35

30

40

34

30

39

33

30

28

 

8

 

50

39

32

27

49

39

32

27

37

31

27

36

31

27

35

30

27

25

 

9

 

47

36

29

24

46

35

29

24

34

28

24

34

28

24

33

28

24

22

 

10

 

44

33

26

22

43

33

26

22

32

26

22

31

26

22

30

25

22

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

4174

23.2

27.8

 

20 x 20

39

45

30

39

0-40

6937

38.5

46.2

 

30 x 30

32

36

24

27

0-60

11814

65.6

78.7

 

30 x 60

31

33

24

23

0-90

15014

83.4

91.5

 

60 x 30

33

36

28

31

0-180

15014

83.4

100.0

 

60 x 60

31

31

28

25

Coefficients of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

88

88

88 88

86

86

86

86

82

82

82

78

78

78

75

75

75

74

 

1

 

81

78

75 72

79

76

73

71

73

71

69

70

68

67

67

66

65

63

 

2

 

74

68

64 60

72

67

63

59

65

61

58

62

59

57

60

58

55

54

 

3

 

68

61

55 51

66

60

55

50

58

53

50

56

52

49

54

51

48

46

 

4

 

63

55

48 44

61

54

48

44

52

47

43

50

46

42

49

45

42

40

 

5

 

58

49

43 38

57

48

43

38

47

42

38

45

41

37

44

40

37

36

 

6

 

54

45

38 34

53

44

38

34

43

37

34

41

37

33

40

36

33

32

 

7

 

50

41

35 30

49

40

34

30

39

34

30

38

33

30

37

33

30

28

 

8

 

47

37

32 27

46

37

31

27

36

31

27

35

30

27

34

30

27

26

 

9

 

44

35

29 25

43

34

29

25

33

28

25

33

28

25

32

28

25

23

 

10

 

41

32

27 23

40

32

26

23

31

26 23

30

26

23

30

26

23

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

6821

25.8

35.1

 

20 x 20

37

41

33

41

0-40

10503

39.8

54.1

 

30 x 30

32

34

28

30

0-60

16195

61.3

83.4

 

30 x 60

31

31

29

27

0-90

19412

73.5

100.0

 

60 x 30

35

36

32

34

0-180

19412

73.5

100.0

 

60 x 60

33

32

33

29

ORDERING INFORMATION

S A M P L E N U M B E R : 2 HBG - 654T5 - A- UNV- EBT2 - U

Width

2=24"

Series

HB=High Bay

Trim Type

G=Grid/Lay-in (Standard)

F=Flange Trim

No. of Lamps

4=4 Lamps

6=6 Lamps

Lamp Type

32=32W T8 Lamps (48")

28T5=28W T5 Lamps (48")

54T5=T5HO Lamps (48")

Distribution Optic

Blank=Medium (Specular Aluminum)

G=Wide (White Painted)

Downlight Optic

Blank=Open

A=Prismatic Acrylic Lens & Aluminum Doorframe CL=Clear Acrylic Lens & Aluminum Doorframe

Voltage(1)

UNV=Universal

120/277 Voltage

UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt

277V=277 Volt

347V=347 Volt

Options

Lamps Installed

L8830=T8 Lamp, 80CRI 3000K

L8835=T8 Lamp, 80CRI 3500K

L8841=T8 Lamp, 80CRI 4100K

L8850=T8 Lamp, 80CRI 5000K

L5830=T5 Lamp, 80CRI 3000K

L5835=T5 Lamp, 80CRI 3500K

L5841=T5 Lamp, 80CRI 4100K

L5850=T5 Lamp, 80CRI 5000K

GL=Single Element Fuse GM=Double Element Fuse Emergency=EM Installed(1)

BallastType

ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB8 /PLUS=T8 Electronic Instant Start.

 

 

 

 

High Ballast Factor >1.13.Total

No. of

Harmonic Distortion < 20%

Ballast

 

1, 2 or 3

 

EBT =T5 Linear Electronic Program Rapid Start.

Total Harmonic Distortion < 10% No. of Ballast

1 or 2

Options

C3=3' Power Cord

C6=6' Power Cord

PC3-=3' Power Cord & Plug

(Specify Voltage)(1)

PC6-=6' Power Cord & Plug

(Specify Voltage)(1)

Packaging

U=Unit Pack

PAL=Job Pack, out of carton PALC=Job Pack, in carton

Accessories (order separately) MWS=Modular Wiring System

NOTES: (1)Voltage must be specified when ordered with plugs, motion or emergency ballasts.

SHIPPING INFORMATION

Catalog No.

Wt.

2HBG-632

42 lbs.

2HBG-654

42 lbs.

 

 

Specifications and Dimensions subject to change without notice.

ADF041664

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

09/02/2008 1:52:21 PM

Image 2
Contents Optics ConstructionElectrical FinishOrdering Information Shipping Information

P4PE-X/TE specifications

Cooper Lighting’s P4PE-X/TE is a revolutionary product in the world of commercial and industrial lighting, offering advanced features and technologies tailored to meet the demanding needs of various environments. This fixture is designed with a focus on energy efficiency, durability, and high-performance illumination, making it an excellent choice for facilities that require both reliability and quality lighting.

One of the standout features of the P4PE-X/TE is its innovative LED technology. LED lights are known for their long lifespan, reduced energy consumption, and lower heat output compared to traditional lighting solutions. This allows for significant energy savings and reduced operational costs over time while minimizing the frequency of replacements. The P4PE-X/TE is engineered to provide up to 100,000 hours of maintenance-free operation, ensuring the longevity and efficiency that businesses seek.

Another critical characteristic of the P4PE-X/TE is its versatile design. This fixture is available in multiple lumen outputs, allowing for customization based on specific lighting requirements. The adjustable mounting options make it suitable for various applications, including warehouses, manufacturing plants, and commercial spaces. Additionally, it features high-performance optics that enhance the distribution of light, reducing glare and improving visibility in workspaces.

The P4PE-X/TE also prioritizes user control and functionality. It is compatible with advanced lighting control systems, which enable dimming, scheduling, and occupancy sensing. This adaptability not only enhances energy savings further but also adds to the overall convenience and efficiency of lighting management.

Furthermore, the rugged design of the P4PE-X/TE ensures it can withstand harsh environments. Its durable housing is resistant to dust and moisture, making it an ideal solution for areas that are subject to challenging conditions. The fixture's robust construction and high ingress protection (IP) rating assure safety and dependability in various applications.

In summary, Cooper Lighting’s P4PE-X/TE stands out with its advanced LED technology, versatility, user-friendly features, and durable build quality. These characteristics make it a top choice for organizations seeking a reliable, efficient, and high-performing lighting solution that meets their specific operational needs while contributing to a more sustainable future. Whether for industrial or commercial applications, the P4PE-X/TE is designed to deliver exceptional performance and longevity, representing a smart investment in lighting technology.