Lucent Technologies 108286063 manual

Page 12

Change Descriptions

34.Turning off TTI did not remove ports that were administered by TTI on cabinets that had been removed, causing translation corruption.

35.Automatic caller information was not displayed if the agent was not in the first split that the call was queued to.

36.DCS transparency was lost because DCS calls saved all processed message buffers for the duration of the call, causing a shortage of DCS message buffers in the switch. Now, the number of messages saved per DCS calls is limited so that more messages are available for other calls, thereby reducing the chances of running out of message buffers resulting in a loss of DCS transparency.

37.Some voice calls on TN767 DS1 circuit packs were randomly considered as data calls, so data tone was connected on these calls and cut-through trunk operation was not allowed.

38.CO-to-CO calls (DID calls that forwarded off-net or that were transferred off-net) could have a transmission level that was too high. This caused instability on these calls at some customer sites.

39.The Adjunct Supervision field did not work correctly when it was set to a VMI set type.

40.Using an abbreviated dialing button for end-to-end signaling was possible only from the originating station or after a trunk flash when the call included a single trunk that was administered to support trunk flash. It did not work from a terminating station under other circumstances. Now, a terminating station can use an abbreviated dialing button to do end-to-end signaling on any facilities that can generate the tones.

41.Page 5 of the display capacity form showed an incorrect system limit for the queue-status buttons.

42.A trunk caller was blocked from picking up another trunk call using TAAS if both trunks were in the same trunk group.

43.The message "Entry is bad" was displayed on the SAT when executing a clear-amw-all-extensioncommand. Now, the message "Command successfully completed" is displayed if the clear-amw-all-extensioncommand is successful. Otherwise, the message "Error encountered, can’t complete request" is displayed.

44.If there were about 200 or more long holding-time trunk calls in the system, ACA caused a system restart.

45.The logged-in agent count in the display-system-capacity form was sometimes higher than the number of agents actually logged in. Now, the count always reflects the actual number of agents logged in.

46.When the "Display Authorization Code?" field was set to n, using an authorization code from a bridged appearance caused other bridged BRI stations to lose these dial keypad functions: touch-tone feedback, local dialed digit display, and retention for redial. Now, these functions are only

10 Issue 2 May 1998

Image 12
Contents Definity Ordering Information Highlights Offer CategoryAnnouncement Boards Audix TransferCall Center Call ClassificationIntegrated Services DIgital Network Isdn UpgradesTerminal Translation Initialization TTI Issue 2 May Feature or category See item numbers Index of ChangesIndex of Changes Change Descriptions Page Page Page