Cooper Lighting M2N-E SLI installation instructions Exploded View and Part Call-Out

Page 1

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

Installation Instructions

Sheet 1 of 3

Roundel, XL

IN/OUTDOOR

P1R (Pendant, 1-way, Remote)

Visor and Non-Visor

Exploded View and Part Call-Out

J-box

(by others)

Electrical cover Canopy plate

1-way Yoke

Aiming screw spacer

Yoke arms

1/4-20 x1" Aiming screw (x2)

End cap

Mounting plate

Pendant length dependant on order

1/4-20 x 4" Hex bolt (x2)

Fixture door

3/8-16x1" Hex end bolt (x2)

Attention:

All extra large fixtures require additional bracing/structure around J-box to support fixture.

1.Securing Pendant to Structure in Ceiling

J-box (by others)

 

Mounting

Appropriate fasteners

plate

 

(by others)

 

#10-32 x 1/2"

 

Pan head screws

 

(x2)

 

 

Canopy

1.Loosen both #10-32 x1/2" Pan head screws and allow canopy to slide down pendant.

2.Feed power wire from j-box into pendant, ensure wire reaches electrical cover plate on base of pendant.

3.Using appropriate fasteners(by others), secure mounting plate to structure/bracing around J-box.

2.

Securing Yoke to Pendant

 

 

1/4-20 x 4" Hex bolt (x2)

1-way yoke

1/4-20 x1"

Button socket screws (x4)

Yoke arms

1.Using all four 1/4-20 x1" screws, secure yoke arms to 1-way yoke.

2.After securing arms, slide 1-way yoke assembly onto pendant and secure using both 1/4-20 x 4" hex bolts.

ADY080866 REV A(ECN080377)

Image 1
Contents Securing Pendant to Structure in Ceiling Exploded View and Part Call-OutSecuring Yoke to Pendant Aiming and Sealing Fixture Securing and Wiring the Fixture Head to PendantLamp Description Mounting Plate Dimensions InmmFixture Size Wattage Lamp Type Lamp Description