Avaya ALGO-3226-CM manual Configure Station, Call Routing to Algo 3226 Trunk Port FXO Doorphone

Page 5

5.2. Configure Station

Use the add station command to add a station for the door attendant that will be called when the call button on the 3226 Doorphone is pressed. The following is a basic H.323 station that was used for this purpose. Other types of stations, like SIP, may also be used.

add station 77301

 

Page

1 of 5

 

 

STATION

 

 

Extension:

77301

Lock Messages?

n

BCC: 0

Type:

9620

Security Code: ****

TN: 1

Port: IP

Coverage Path 1:

 

COR: 1

Name: Door Attendant

Coverage Path 2:

 

COS: 1

 

 

Hunt-to Station:

 

 

 

 

 

 

 

STATION OPTIONS

 

 

 

 

 

Time of Day Lock Table:

 

Loss Group:

19

Personalized Ringing Pattern:

1

 

 

Message Lamp Ext:

77301

Speakerphone:

2-way

Mute Button Enabled? y

Display Language: english

 

 

Survivable GK Node Name:

 

 

 

Survivable COR: internal

Media Complex Ext:

 

Survivable Trunk Dest? y

IP SoftPhone? n

 

 

 

 

IP Video? n

Short/Prefixed Registration Allowed: default

Customizable Labels? y

5.3. Call Routing to Algo 3226 Trunk Port FXO Doorphone

To route calls to the doorphone, a uniform dialplan and AAR routing was used. In the Uniform- Dialplan form add an entry for extension 77777. When this extension is dialed, the call will be routed using AAR to the doorphone.

change uniform-dialplan 7

 

Page

1 of

2

 

UNIFORM DIAL PLAN TABLE

 

 

 

 

 

Percent Full: 0

 

 

 

 

 

 

 

Matching

 

Insert

Node

 

 

Pattern

Len Del

Digits

Net Conv Num

 

 

77777

5 0

 

aar n

 

 

 

 

 

 

 

 

In the AAR Analysis form, add entry for 77777 to route calls to the Route Pattern 100, which specifies the loop start trunk connected to the doorphone.

change aar analysis 7

 

 

 

 

 

Page

1 of

2

 

 

AAR DIGIT ANALYSIS TABLE

 

 

 

 

 

 

 

Location: all

 

Percent Full: 1

 

Dialed

Total

Route

Call

Node

ANI

 

 

String

Min

Max

Pattern

Type

Num

Reqd

 

 

77777

5

5

100

aar

 

n

 

 

JAO; Reviewed:

Solution & Interoperability Test Lab Application Notes

 

5 of 8

SPOC 11/3/2011

©2011 Avaya Inc. All Rights Reserved.

 

Algo-3226-CM

Image 5
Contents Abstract Introduction Interoperability Compliance TestingGeneral Test Approach and Test Results Test ResultsLAN Reference ConfigurationConfigure Loop Start Trunk Configure Avaya Aura Communication ManagerEquipment and Software Validated Hardware Component VersionCall Routing to Algo 3226 Trunk Port FXO Doorphone Configure StationGrp FRL Configure Algo 3226 Trunk Port FXO DoorphonePattern Number 100 Pattern Name 3226 Doorphone Verification Steps In-service/idleConclusion Additional ReferencesAvaya Inc. All Rights Reserved