StarTech.com RS-232 Troubleshooting, While in Data mode, automatic link can not be established

Page 14

Instruction Manual

Troubleshooting

I am unable to access Configuration mode when pushing the MODE button?

Turn off the power to the Bluetooth to Serial Adapter, and remove it from your serial (RS- 232/422/485) device. Then apply power to it, and try again (like a hardware RESET)

While in DATA mode, automatic link can not be established

1)Ensure the remote MAC address is set correctly.

2)Ensure the PIN code is correctly entered, and that it is identical between devices.

3)Repeat the configuration processes for the two devices again to ensure all settings are correct.

Garbage code is being received

Usually this means that the wrong RS-232/422/485 parameters were set, such as baud rate or parity bit. Reconfigure your Bluetooth to Serial Adapter to a correct setting.

Mass data transmission will stop midway or receive garbage code Please select “Hardware” in flow control setting.

Cannot connect the Bluetooth to Serial Adapter when in Remote Setup Ensure that the Bluetooth to Serial Adapter is staying in DATA mode. If YES, please disconnect the link first. This can be done by turning off the power of another Bluetooth device with which this Bluetooth to Serial Adapter is linked.

Turn off power of Bluetooth to Serial Adapter, then restore power. Push the MODE button to get into Configuration mode.

Reconfigure Bluetooth to Serial Adapter, without the previous baud rate setting Turn off power to the Bluetooth to Serial Adapter, then restore power. Push the MODE button immediately before it automatically links with another Bluetooth device (i.e. prevent the link from being built). Baud rate will default to 115200, which allows you to access configuration mode.

11

Image 14
Contents Serial to Bluetooth Adapter FCC Compliance Statement Table of Contents Introduction FeaturesContents Before You BeginInstallation Pairing with Windows XP SP2 embedded Bluetooth driverMaster state Configuration Role Master or Slave DefaultSlave State Default Remote MAC Address Configuration SecurityConfiguration Uart Configure Configuration Adapter Name More Detail on Initial Baud Rate SettingRemote Setup Page Configuring the Adapter following Remote Setup Highlight Uart ConfigureHighlight Local Device Name Configuration Adapter Name Default Serial AdapterApplication Start Program Accessories Communications Hyper Terminal Garbage code is being received TroubleshootingWhile in Data mode, automatic link can not be established Accessories SpecificationsTechnical Support Warranty Information Limitation of LiabilityAbout StarTech.com