Avaya Inc.
Installation and Operation
Model EA401
Wiring For Tip & Ring
•After mounting the telephone follow these steps.
•Run tip, ring and ground wires from the local exchange into the lower junction box. The tip and ring wires must not be connected to the local exchange until installation is completed. A sealing fitting must be installed within 45.7 cm (18") on the exchange side of the lower junction box.
•Attach the tip and ring wires to the orange and blue wires from telephone using twist on wire connectors. Attach #10 ring lugs to the end of the three green wires and attach these wires to the ground screw in the junction box.
•For tone (DTMF) dialing operation of the telephone, connect the two brown wires together and protect the connection with a
•Check the wiring and close the junction box.
See: Figure 4 - Lower Junction Box Wiring
| TO EA401 |
GROUND (GREEN) |
|
| TIP & RING |
TONE/PULSE SWITCH | (BLUE & ORANGE) |
(BROWN) | NOT POLARITY SENSITIVE |
TONE/PULSE: CONNECT | FROM EXCHANGE |
WIRES AND KEEP WIRES |
|
ISOLATED |
|
TIP
RING
GROUND
Figure 4 - Lower Junction Box Wiring
Page 8