Whirlpool AWM 250 3 service manual S E R V I C E, Technical data, Drain pump synchronus

Models: 250

1 14
Download 14 pages 47.68 Kb
Page 3
Image 3
Drain pump (synchronus)

S E R V I C E

Technical data

Whirlpool Europe

AWM 250/3

17.08.1998 / Page 3

Customer Service

8570 250 10010

Doc. No: 4812 712 13517

 

 

 

Drain pump (synchronus)

 

 

Nominal voltage

 

230

V

Nominal current

 

0.3

A

Nominal consumption

34

W

Frequency

 

50

Hz

Resistor (coil)

 

155

Ω ± 7%

Motor protection

 

no

l/min. ± 2

Capacity (1.25m height)

15

Program timer

 

 

 

Type

Hybridtimer with integreated

 

electronic

 

Fab.

 

EC 4477

 

 

 

(Timer 2 a mask5)

Nominal voltage

 

230

V

Frequency

 

50

Hz

Total positions

 

60

 

Cotton/coloured laundry

 

 

Pre wash

pos.

01 - 02

 

Main wash

pos.

03 - 12

 

Rinse

pos.

13 - 19

 

Spin

pos.

20 - 22

 

Stop

pos.

23

 

Easy care

 

 

 

Pre wash

pos.

24 - 26

 

Main wash

pos.

27 - 34

 

Rinse

pos.

35 - 39

 

Spin

pos.

40 - 41

 

Stop

pos.

42

 

Delicate

 

 

 

Pre wash

pos.

43 - 44

 

Main wash

pos.

45 - 51

 

Rinse

pos.

52 - 56

 

Spin

pos.

57 - 59

 

Stop

pos.

60

 

Wool

 

 

 

Pre wash

pos.

-

 

Main wash

pos.

47 - 51

 

Rinse

pos.

52 - 56

 

Spin

pos.

57 - 59

 

Stop

pos.

60

 

Silk

 

 

 

Pre wash

pos.

-

 

Main wash

pos.

49 - 51

 

Rinse

pos.

52 - 56

 

Spin

pos.

57 - 59

 

Stop

pos.

60

 

Motor

 

 

 

Type

MCA 52/64 - 148 t.f./WHE0

 

i = 1 : 13.1

 

Resistance contacts

 

Ω ± 7%

6 - 7

 

68.70

4 - 5

 

2.15

Ω ± 7%

2 - 3

 

1.46

Ω ± 7%

1 - 3

 

0.65

Ω ± 7%

Radio interference supression

 

Type

 

Friburg FA 26

Nominal voltage

 

230

V

Nominal capacity

 

470nFX1+2x22nFY

Nominal inductances

2 x 1

mH

Nominal resistance

680

kΩ

Selector switch

 

 

 

Positions

 

7

 

Nominal voltage

 

5

V

Value of resistors:

 

 

 

1-2-3

 

internal shunt

4-6

 

internal shunt

5-6

 

pos.1

0 Ω

 

 

pos.2

0.68 kΩ± 5%

 

 

pos.3

1.10 kΩ± 5%

 

 

pos.4

1.80 kΩ± 5%

 

 

pos.5

2.70 kΩ± 5%

 

 

pos.6

3.60 kΩ± 5%

 

 

pos.7

4.70 kΩ± 5%

Push botton switch

 

 

 

Start stop

 

SM

 

1/2 load

 

SHL

 

Eco

 

SEC

 

Pre wash

 

SPW

 

Rapid

 

SR

 

Page 3