5 A) Connect modular telephone cords to 206 module extension jacks, starting at the top extension jack on the leftmost module.

B)Route each cord through the hook on the front of the module, and then push the cords through the space below the module and out through the back.

C)Pull the cords from behind the backplane, leaving at least two feet (0.6 meters) of slack to allow easy replacement of system modules (for future maintenance so you can easily reconnect cords after replacing system modules).

D)Connect the free end of each modular telephone cord to the modular connecting blocks for system extensions.

6 A) Place the cover on the control unit—this is especially important to keep the modules dust-free and the system working efficiently. To cover the control unit, while holding the cover at an angle, gently move the top rear edge of the cover over the top of the control unit.

B)Match up the grooves where the top edge of the cover meets the backplane, and gently push the edge into place.

C)Lower the bottom of the cover until it is secured in place.

Installation Procedures

11

Image 15
Contents AT&T Canadian Emissions Requirements Copyright 1993 AT&T All Rights Reserved Issue OctoberWarranty Federal Communications Commission FCC Interference NoticeContents Additional Safety Instructions for Installation Personnel Important Safety InstructionsOverview InstallationAn Example System Setup Control UnitExtensions Control Unit Extensions Required Parts Required PartsTelephones and Devices Installation GuidelinesCombination Extensions Using a Bridging Adapter Using a Direct ConnectionInstalling the Control Unit and Modules Installation ProceduresMain Circuit Breaker Power Jack Lights Connecting Lines and Extensions Page Connecting Caller ID Display Units Desk Mounting Assembling System PhonesWall Mounting Wall Mounting Phones with Separate StandsWall Mounting Phones with Fixed Stands Possibly damage the equipment Connecting and Testing TelephonesPaging System Music-on-Hold Audio SourceCall Reporting Smdr Printer For the Intercom Autodialer Connecting Intercom AutodialersAdding New Modules Equipment UpgradesReplacing System Modules Equipment Upgrades Specifications Smdr Output WiringExtension JackLocal Phone SafetyGovernment Approvals518-455-218 October