Guardian Technologies WRT-40-A, WRT-10-A, WRT-30-A manual Dtmf or 33/66 Pulse AT 10 PPS

Page 8

Guardian Telecom Inc.

 

 

Installation and Operation

 

 

Model WRT-A

 

 

 

 

Engineering Specifications

 

*ELECTRICAL PERFORMANCE

 

 

 

 

 

 

 

AUDIBLE RANGE FREQUENCY RESPONSE

300 – 3400 HZ

 

 

DIALING METHOD

DTMF OR 33/66 PULSE AT 10 PPS

 

 

SEND LOUDNESS RATING (SLR) dB

SHORT 8 dB +/- 4 dB

 

 

RECEIVE LOUDNESS RATING (RLR) dB

SHORT -4 dB +/- 4 dB

 

 

SIDE TONE MASKING RATING (STMR)

>11 dB

 

 

RINGER OUTPUT

75 dB MAXIMUM

 

 

RINGER EQUIVALENCE

0.5

 

 

SET IMPEDANCE

600 OHMS NOMINAL

 

 

MAXIMUM LOOP

15,000 FT (4,600 M) OF 22 AWG COPPER

 

 

ELECTRICAL

 

 

 

 

 

 

 

RINGER SENSITIVITY

40 – 100 V, 16 – 25 HZ

 

 

LINE VOLTAGE

24 – 56 VDC

 

 

LOOP CURRENT

20 - 120 mA

 

 

CONNECTION METHOD

SURGE ARRESTOR / TERMINAL BLOCK

 

 

FUSE

¼ AMP 250 VOLT 3AG FAST BLOW

 

 

ENVIRONMENTAL

 

 

 

 

 

 

 

WEATHERPROOF

ENCLOSURE NEMA 3R

 

 

TEMPERATURE

-40OTO +60O C (-40OTO +140O F)

 

 

HUMIDITY

0 TO 95% RH

 

 

DUSTPROOF

FULLY GASKETED FACEPLATE & WEATHERPROOF KEYPAD

 

 

CORROSION RESISTANT

MIL-STD-810E SALT FOG

 

 

MECHANICAL

 

 

 

 

 

 

 

HOOK SWITCH (CRADLE SWITCH) LIFE

>1 000 000 OPERATIONS

 

 

BODY CONSTRUCTION

GE VALOX 357® ENGINEERING POLYMER

 

 

DIMENSIONS

12 X 9.6 X 3.9 INCHES (305 X 245 X 99 MM)

 

 

NET WEIGHT

6.5 LBS (2.95 KG)

 

 

HANDSET MATERIAL

HIGH IMPACT ABS

 

 

MICROPHONE

NOISE REDUCING ELECTRET

 

 

OPTIONAL MICROPHONE

NOISE CANCELING DYNAMIC

 

 

RECEIVER

HEARING AID COMPATIBLE (HAC)

 

 

STANDARD MOUNTING

VERTICAL WALL

 

 

WIRING ACCESS

7/8” DIAM. OPENING FOR OWNER SUPPLIED FITTING

 

 

 

 

 

Page 8

Image 8
Contents Weather Resistant Industrial Telephones Table of Figures Standard Features On All Models Installation and Operation Model WRT-A Guardian Telecom IncHard Wiring the WRT-A to the Telephone System OperationMounting Final CheckSetting Dialing Mode & Installation Fuse Replacement Dtmf or 33/66 Pulse AT 10 PPS Replacement Parts DescriptionACA Rules and Ringer Equivalence Number Service changes and LimitationsNotification to Telephone Company Service Telephone Number DisclaimerFeedback North AmericaStep I On-Site Correction Step II Return Materials Authorization RMAStep III Factory Authorized Service Model No Serial No Date of Purchase Page Page Industrial Communications Worldwide