TOA Electronics TOAEXES-5OOO manual Speech and Function Test

Page 10

8-4. SPEECH AND FUNCTION TEST

1.Speech Test

After completing the wiring check and the power supply

and exchange test according to the system flow chart,

the speech test for each station can then take place.

IMPORTANT NOTE

Before testing, all programming (Secretary transfer,

Master/Substation, Executive Priority Function) must

be cleared from station No.200 by turning on the PRO-

GRAM switch of the CPU, or the speech test can not

proceed correctly.

Call every station one by one from any master station

and examine the speech quality and sound volume.

The sound volume can be adjusted by the volume on the

rear of the station. (Fully clockwise for maximum)

A call to a station in the room produces reverbera-

tion and may present broken sound. Turn down the

volume of the station speaker until the sound becomes

normal.

Each station must be located properly where no feed-

back will occur between station and external speakers.

The gain adjustment of the paging amplifier is also

important in order to avoid troublesome feedback.

The Press-To-Talk bar on the station keyboard must be

used for the speech test when stations are installed

in high noise areas (more than 60dB noise).

Speech quality (broken sound, natural conversation,

tone quality, etc.) must be tested with each line in

the CLU or DLU employed in the system.

-68-

Image 10
Contents TOAEXES-5OOO Trouble Shooting Guide Start Is voltage selector set correctly? HOW to Find Short Between T-LINE and R-LINE Exchange Exchange Fault in Specific Station only Produces reverberation Speech and Function Test Use all number keys Memo Memo EX57-01R79-2