TOA Electronics TOAEXES-5OOO manual Is voltage selector set correctly?

Page 4

8-1. FAULT IN EXCHANGE

Before power supply check, confirm the following three points to eliminate elementary faults:

1.Is voltage selector set correctly?

2.Is AC power supplied?

3.Is power switch ON?

Start checking after disconnecting all wiring connected to DC output of the power supply unit.

SYMPTON

CHECK-ITEM

 

Exchange does not

All DC output

Over-current flows into one

operate.

voltages are

of plug-in units.

 

correct.

 

 

All or one of

Fault in the power supply

 

DC output

unit DS-510.

 

voltages are

 

 

not correct.

 

Abnormal voltage

Right

range:

Replace AC and DC fuses.

of +24V terminal.

+24 ~ +30V

Incorrect setting of the

 

 

 

voltage selector.

 

 

 

Faulty power transformer.

Abnormal voltage

Right

range:

 

of +18V.

 

 

 

Abnormal voltage

Right

range:

DC/DC inverter (MIV-02) is

of +5V or +12V.

 

 

defective.

Battery is not

Check

the cur-

Replace PCB of charging

charged.

rent

flowing

circuitry.

 

into

the bat-

 

 

tery.

 

 

 

Right

range:

 

AC & DC operation

Check all DC

lamps

are OFF.

voltage.

Buzzer

does not

 

operate.

Note: Only when DC

power supply (Battery) is employed.

Blown AC and/or

All DC output

DC fuse.

voltages are

 

correct.

 

heck

all sta-

 

tions

involv-

 

ed in All-Call

 

paging.

Replace PCB of charging circuitry.

Over-current flows into one of plug-in units.

(Especially on +18V)

MIV-02 is defective. Replacefuseaccordingto the following.

Number of stations

Fuse

0 ~ 30

DC 5A

31 ~ 64

DC

7A

65~

DC

10A

-62-

Image 4
Contents TOAEXES-5OOO Trouble Shooting Guide Start Is voltage selector set correctly? HOW to Find Short Between T-LINE and R-LINE Exchange Exchange Fault in Specific Station only Produces reverberation Speech and Function Test Use all number keys Memo Memo EX57-01R79-2