Telex BP-1002, BP-2002 operating instructions Operating Modes

Page 9

Local Power Input (BP-2002 only)

Normally the BP-2002 is powered from the intercom system and will turn on with the intercom system. The BP-2002 belt pack may also be powered from an optional power supply (18-30 VDC) connected be- tween pin 2 (+) and pin 1 (-) of the intercom channel connector.

8.INTERCOM CHANNEL CONNECTORS: On the BP-1002, the

intercom channel is connected via a pair of 3-pin connectors (one male and one female). The male and female connectors are wired together in parallel, providing a “loop through” at each connector pin. Use one connector to connect to the intercom channel.

Use the other connector to “daisy chain” a cable to the next belt pack or other station on the channel.

OPERATING MODES

The microprocessor within the BP-1002/BP-2002

controls four modes of operation that affects the Microphone Kill and Audible Call Alert features.

MODE

MIC KILL

AUDIBLE

(BEEPS)

CALL ALERT

 

 

 

 

1

Disabled

Disabled

 

 

 

2 (Default)

Enabled

Disabled

 

 

 

3

Disabled

Enabled

 

 

 

4

Enabled

Enabled

 

 

 

Table 1. Operating Modes

9

Image 9
Contents Telex Page Introduction End-User License Agreement for Telex Software Initial BP-1002/BP-2002 Setup System PowerBP-2002 & BP-1002 Connections and Controls Connections and Controls External Connections & ControlsIntercom Channel Connectors On the BP-2002 Operating Modes Changing Modes of Operation Internal SWITCHES, Jumpers and Adjustments Side Tone Adjustment R145 Internal Switches and Jumpers Headset Connector Connector PIN ConfigurationsBP-2002 Interface Requirements GeneralHeadphone Amplifier Electret Microphone Amplifier Dynamic Microphone AmplifierBoard Number Eliminating MIC-KILL and Call Signal Restoring MIC-KILL and Call SignalGeneral Description Printed Circuit Board Factory Service