Polycom RSS 2000 manual Known Limitations

Page 34

RSS 2000 Getting Started Guide & Release Notes – Version 3.0.2

Known Limitations

Table 9 Known Limitations

Subject

Description

Overlapping names

The monitor screen displays an overlapping names of VSX8000 and

RSS in a MGC meeting room

 

 

 

VSX 5000-8000

The RSS 2000 support the VSX 5000-8000 when the VSX is set to

Interoperability

motion (Not Sharpness nor Promotion)

 

 

 

The RMX 2000 connects secondary to the RSS 2000 in the rate of

RMX 2000

64Kbps (No support for G.728 at the RMX 2000 (RMX 2000 connect

to the HDX and VSX at G.729A in 64K which is not supported by the

Interoperability

RSS 2000)) – recording at this low video rate is not recommended in

 

 

any case.

 

 

RMX 2000

While RSS 2000 is connected to RMX2000 in SIF when the RMX is

Interoperability

set to Sharpness , an archive of it is tagged as H.264 SD.

 

 

ViewStation

ViewStation show blue then green screen at the beginning of a

Interoperability

connection to RSS 2000

 

 

IVRs

When recording an IVR message – it’s require to add additional 1

second of silence for each recording, to prevent message truncation

 

with VSX and Viewstations

 

 

Maximum frame rate

Maximum frame rate for recording and playback in the recording room

for recording and

is 20 fps in H.264 and 25 fps in H.261/H.263

playback

 

 

 

Point to Point

HD is not supported in Point to Point recording. When using an HD

endpoint it’s recommended to dial directly to the recording room [RSS

recording

2000 Prefix][Recording Room Prefix] and not to connect to the

 

Recording room via the H323 Menu.

 

 

Embedded Multipoint

When recording a multipoint on a VSX – first connect the endpoint to

on the VSX

the VSX and only than connect to the RSS 2000

 

 

Sony HG90 version:

Sony HG90 can connect in HD only. The RSS 2000 menu is in CIF

2.11 Beta

(Not in HD) as so the HG 90 will connect as secondary.

Interoperability

 

 

 

H239 Content

The RSS 2000 support H263 content (Not H264) – as most endpoint

currently support H263 content – in order to prevent interoperability

resolution

issue, when playing back the stream (In H323) the RSS will not

 

support H264 content (Lower common nominator)

 

 

Econf integration

France Telecom eConf can not get video from RSS

 

 

 

Connect Aethra X7 to RSS 2000 @1920K ,the X7 sends 720p, but

Aethra X7 integration

receives CIF from the RSS 2000.

 

RSS 2000 can only support CIF/SIF for menu.

 

 

RMX 2000 integration

HD Recording with the RMX 2000 is supported only on full screen

layout.

 

 

 

26

Image 34
Contents Polycom RSS Getting Started Guide Release Notes Catalog No. DOC2207C Version Regulatory Notices Page Table of Contents Page Polycom RSS 2000 Getting Started Guide VersionPage General Safety Precautions Parameter DescriptionIP Address192.168.1.254 First Time Installation and ConfigurationGateway Open a browser and go to http//192.168.1.254 Help Reset Password back to polycomChanging the IP Address First Time Installation and Configuration RSS 2000 Maximum Capacity Scenario Description Maximum CapacityNetwork TCP/UDP ports used by RSS Usage Type Port RangeRSS 2000 Getting Started Guide & Release Notes Version Page Page Polycom RSS 2000 Release Notes RSS 2000 V3.0.2 Upgrade Guide To get K-keycodeTo get U-keycode RSS 2000 Getting Started Guide & Release Notes Version Existing Systems Software upgrade only, no new installation How to generate keycodesDownload upgrade package to RSS Activate RSS KeycodeRSS 2000 V3.0.2 Upgrade Guide Upgrade from 2.0 to RSS 2000 V3.0.2 Upgrade Guide Upgrade from V3.0.0 or V 3.0.1 to PHP V5.2.6 Upgrade New Feature and Bug Fixes Compare with New Feature and Bug Fixes of VersionRSS 2000 Policies and Limitations Subject DescriptionRSS Subject Description Known Limitations RSS can not encode 2CIF/2SIF as a standard resolution when Pending issues