INSTALLER'S TROUBLESHOOTING GUIDE
TROUBLE | POSSIBLE CAUSE | POSSIBLE REMEDY |
|
|
|
No radio, no intercom. | No electrical power. | Be certain 120VAC, 60Hz power has been provided to the primaries of |
(No Display). |
| both 301T Transformers. No less than 16VAC should be measured on |
|
| the secondary of either Transformer. |
|
|
|
| Defective transformer. | Replace transformer. |
|
|
|
No radio, intercom working. | Faulty Master Station. | Isolate Master Station from installation by removing ribbon cables from |
(AM/FM indicator on.). |
| terminal board and wait one minute for timeout. With power on, radio |
|
| should be playing at Master. If no radio, Master is probably faulty. If |
|
| radio plays, reconnect ribbon cables. |
|
|
|
| Installation problem. | Check terminal board for shorted terminals or miswired cables. |
|
| Remove one |
|
| comes on, check speaker connections and run continuity check of |
|
| speaker wiring. |
|
|
|
| Antenna problem. | Check for shorted antenna connection. Remove antenna connector |
|
| from tuner board and touch each pin with metallic object. If radio plays, |
|
| antenna is not functioning; be sure it is installed properly. In weak |
|
| signal areas, an outside antenna may be necessary. Also see |
|
| Connecting Auxiliary AM Antenna |
|
|
|
Low or distorted radio | Incorrect volume setting. | Follow “Setting Volume” instructions under OPERATIONAL |
volume. |
| CHECKOUT. |
|
|
|
Low or no intercom volume | Improper operation. | Be sure remote speaker set for MONITOR has its volume control set |
from remote speaker in |
| between 1⁄2 and max, and receiving speakers have volume controls set |
MONITOR mode. |
| between 1⁄2 and max. Follow “SETTING VOLUME” instructions in |
|
| Operation Checkout. |
|
|
|
| Program and Intercom Volume | Follow these instructions whenever the radio tends to overpower |
| Control adjustment. | transmissions from a remote speaker in the MONITOR mode. These |
|
| instructions will help you get the proper balance between the radio and |
|
| the monitored speaker. |
|
| 1. Set system volume control to midpoint. |
|
| 2. Set master to CD/TAPE or AUX position. |
|
| 3. Adjust volume control for each remote station and speaker in |
|
| master station 3⁄4 position. |
|
| 4. Set master to AM or FM and tune to a strong AM or FM station. |
|
| 5. Adjust program volume control for a desired listening level. |
|
| 6. Increase Intercom volume control setting. Adjust clockwise to |
|
| desired monitor volume. |
|
|
|
System squeals when using | Shorted wire on master or | Check for short between terminals or loose wire. |
intercom. | remote terminal board. |
|
|
|
|
| Two or more Remote Stations on | Make separate cable |
| same wire run to Master. | Master. |
|
|
|
| Speakers in adjacent rooms | If speakers are mounted directly back to back, one speaker will have to |
| mounted on common wall, or | be relocated. If speakers are in a common wall, try placing fiberglass |
| mounted back to back. | insulation behind each speaker, or isolate the speakers from the wall |
|
| by placing rubber washers or weather stripping between speaker and |
|
| wall. |
|
|
|
| Improper wire used in | NuTone Model |
| installation. |
|
|
|
|
| Improper double connections | Follow “Connecting the Remote Speaker Wiring” under |
| of Remote Stations on terminal | INSTALLATION. |
| screws 1, 2, 6 & 7. |
|
|
|
|
12