INSTALLER'S TROUBLESHOOTING GUIDE

TROUBLE

POSSIBLE CAUSE

POSSIBLE REMEDY

 

 

 

No radio, no intercom.

No electrical power.

Be certain 120VAC, 60Hz power has been provided to the primaries of

(No Display).

 

both 301T Transformers. No less than 16VAC should be measured on

 

 

the secondary of either Transformer.

 

 

 

 

Defective transformer.

Replace transformer.

 

 

 

No radio, intercom working.

Faulty Master Station.

Isolate Master Station from installation by removing ribbon cables from

(AM/FM indicator on.).

 

terminal board and wait one minute for timeout. With power on, radio

 

 

should be playing at Master. If no radio, Master is probably faulty. If

 

 

radio plays, reconnect ribbon cables.

 

 

 

 

Installation problem.

Check terminal board for shorted terminals or miswired cables.

 

 

Remove one 3-wire cable at a time to locate faulty line. When radio

 

 

comes on, check speaker connections and run continuity check of

 

 

speaker wiring.

 

 

 

 

Antenna problem.

Check for shorted antenna connection. Remove antenna connector

 

 

from tuner board and touch each pin with metallic object. If radio plays,

 

 

antenna is not functioning; be sure it is installed properly. In weak

 

 

signal areas, an outside antenna may be necessary. Also see

 

 

Connecting Auxiliary AM Antenna

 

 

 

Low or distorted radio

Incorrect volume setting.

Follow “Setting Volume” instructions under OPERATIONAL

volume.

 

CHECKOUT.

 

 

 

Low or no intercom volume

Improper operation.

Be sure remote speaker set for MONITOR has its volume control set

from remote speaker in

 

between 12 and max, and receiving speakers have volume controls set

MONITOR mode.

 

between 12 and max. Follow “SETTING VOLUME” instructions in

 

 

Operation Checkout.

 

 

 

 

Program and Intercom Volume

Follow these instructions whenever the radio tends to overpower

 

Control adjustment.

transmissions from a remote speaker in the MONITOR mode. These

 

 

instructions will help you get the proper balance between the radio and

 

 

the monitored speaker.

 

 

1. Set system volume control to midpoint.

 

 

2. Set master to CD/TAPE or AUX position.

 

 

3. Adjust volume control for each remote station and speaker in

 

 

master station 34 position.

 

 

4. Set master to AM or FM and tune to a strong AM or FM station.

 

 

5. Adjust program volume control for a desired listening level.

 

 

6. Increase Intercom volume control setting. Adjust clockwise to

 

 

desired monitor volume.

 

 

 

System squeals when using

Shorted wire on master or

Check for short between terminals or loose wire.

intercom.

remote terminal board.

 

 

 

 

 

Two or more Remote Stations on

Make separate cable (IWA-3) runs from each Remote Station to the

 

same wire run to Master.

Master.

 

 

 

 

Speakers in adjacent rooms

If speakers are mounted directly back to back, one speaker will have to

 

mounted on common wall, or

be relocated. If speakers are in a common wall, try placing fiberglass

 

mounted back to back.

insulation behind each speaker, or isolate the speakers from the wall

 

 

by placing rubber washers or weather stripping between speaker and

 

 

wall.

 

 

 

 

Improper wire used in

NuTone Model IWA-3-conductor, flat-ribbon cable must be used.

 

installation.

 

 

 

 

 

Improper double connections

Follow “Connecting the Remote Speaker Wiring” under

 

of Remote Stations on terminal

INSTALLATION.

 

screws 1, 2, 6 & 7.

 

 

 

 

12

Image 12
Contents RADIO-INTERCOM System Installation Wiring SpecificationsSpeaker Wiring Mounting the Terminal BoardWire Matching Chart Connecting the RemoteConnecting the Door Speaker WiringMounting the Master Panel Connecting Antenna Installing and Connecting Optional Door Release Push ButtonSelecting Remote Radio Control Features Connecting Optional Accessories Connecting the Master Panel to the Terminal BoardConnecting the Transformers Models IA-28 or IA-29Model IA-29 only Securing the Master Panel System Operating Controls Master Station ControlsSetting System Volume Setting Intercom VolumeDigital Clock Operational CheckoutDiagnostic Tests Operational CheckoutInstallers Troubleshooting Guide Trouble Possible Cause Possible RemedyElectrical fixtures Page Page Two Year Limited Warranty