3M 2470, 2475 installation instructions Wiring Call Stations, Wiring Station Selectors

Page 11

Performance Series

Wiring The System

Configuration Worksheets

Use Configuration Worksheets 1 through 3 (located at the end of this document) to plan and record your system configuration. You can record the system wire locations, wire color scheme, and program settings on the worksheets. Store the worksheets inside the cover of the Communications Controller.

Wiring Call Stations

Call Station wiring consists of the following for a one-button, four-wire system:

2 Speaker wires.

Speaker shield wire (used as Common for buttons).

Call switch.

LED wire. (if Call Station contains LED)

Configuration Worksheet 1 shows how to connect the Call Stations to the proper Communications Controller ports.

Wiring Station Selectors

!Important

The D-2400 System is powered by one power supply that provides power for the Communications Controller and a maximum of three Station Selectors. A separate power supply (3M part number 78-8095-0910-8) must be plugged into each Station Selector that exceeds the three Station Selector limit. We recommend installing a separate power supply if the cable length from the Station Selector to the Communications Controller exceeds 100 feet.

Wiring Station Selectors involves connecting a minimum of 7 wires: 3 audio wires and 4 power and communications wires.

Figure 8. Connecting Optional Accessories to Station Selector

Refer to Configuration Worksheets 2 and 3 to determine the specific wires and connections to be made.

7

Image 11
Contents Wired Intercom System  3M IPC 2002. All rights reserved Front Matter Table of Contents System Components Be sure the system is powered off Card InstallationCard and Noise Reduction Module Communications Controller Power SupplyStation Selectors Call StationsWiring the System Wiring Station Selectors Wiring Call StationsInitializing the System Wiring Communications ControllerPump Mode and Island Mode System Mode SelectionInitialization Instructions for Island Mode Initialization instructions for Pump Mode factory defaultParameter # Name/Value Programming StateParameter Selection Error MessageThis value must be adjusted after adjusting Talk volume ‘ T a L K’ = Yes Are You Sure ? ‘T a L K’ = Yes Keypad Function Definitions for Text entry Programming State Left Arrow VOX Voice Operated Transmission Sensitivity Level Inbound Audio Volume LevelOutbound Talk Volume Level Testing the Functions Configuration Worksheets Configuration Worksheets Configuration Worksheets Page Commercial Care Division

2475, 2470 specifications

3M has long been recognized as a leader in innovative solutions across various industries, and the 3M 2470 and 2475 are prime examples of the company's commitment to quality and technological advancement. These products are specialized filters that provide exceptional filtration performance, particularly in environments where air quality is a concern.

The 3M 2470 filter is designed for use in respiratory protection systems, specifically in conjunction with a half or full-face respirator. Its primary function is to filter out particulates and certain aerosols, making it an essential tool for professionals working in industries such as construction, healthcare, and manufacturing. The filter boasts a lightweight yet durable design, ensuring comfort for long periods of wear. One of the standout features of the 3M 2470 is its advanced electrostatic filtering technology, which enhances its efficiency in trapping airborne particles while reducing breathing resistance. This technology not only improves the filter's performance but also contributes to increased user comfort.

The 3M 2475 filter, on the other hand, is a versatile option that combines particulate and gas vapor filtration. It is particularly beneficial for environments where both dust and chemical exposure are present. Like the 2470, the 2475 utilizes advanced filtration technology, incorporating cartridges that can effectively capture harmful gases, vapors, and particulate matter. This dual protection feature makes the 2475 filter an excellent choice for industries such as paint spraying, chemical processing, and in laboratories.

Both the 2470 and 2475 filters are designed with ease of use in mind. They can be effortlessly attached to compatible respirators and feature a low-profile design that minimizes obstruction during use. The filters' compatibility with numerous 3M respirator models ensures that professionals can easily integrate them into their existing safety gear.

In terms of characteristics, both models excel in delivering high levels of filtration efficiency, with the 2475 offering enhanced protection against specific gases. The filters are also designed to maintain a compact and lightweight profile, making them suitable for use in a variety of demanding environments. Furthermore, the materials used in these filters are both robust and resistant to wear, ensuring longevity and reliability in challenging conditions.

Overall, the 3M 2470 and 2475 filters exemplify the company's dedication to creating innovative and effective respiratory protection solutions. With their advanced technologies, user-friendly designs, and exceptional performance characteristics, these filters represent a crucial investment for professionals seeking to enhance their safety and health in the workplace.