Panasonic Complete Guide to the KX-TDE100 Manual for Pure IP-PBX Installation

Page 1

Pure IP-PBX

Installation Manual

Model No. KX-TDE100

KX-TDE200

Thank you for purchasing a Panasonic Pure IP-PBX.

Please read this manual carefully before using this product and save this manual for future use.

KX-TDE100/KX-TDE200: PMMPR Software File Version 1.0000 or later

SD Logo is

a trademark.

Image 1
Contents Model No. KX-TDE100 Pure IP-PBXIpcmpr Option Cards Main Processing CardActivation Key Cards Virtual Trunk CardsPhysical Extension Cards KX-TDA0290CE/CJOther Physical Cards Incompatible Panasonic Proprietary Telephones Compatible Panasonic Proprietary TelephonesList of Abbreviations Important NoticeSecurity Requirements What is User Information?For All Telephone Equipment Safety RequirementsFor the PBX Installation Manual For users in Germany only For business users in the European UnionFor users in Finland, Norway and Sweden only For users in New Zealand onlyFor users in Taiwan only For users in Australia onlyAbout the Other Manuals Structure of this ManualAbout the software version of your PBX TrademarksInstallation Manual Precautions for Users in the United Kingdom Installation Manual Table of Contents Information about the Other Physical Cards 132 Information about the Physical Extension Cards 116Connection of Extensions 143 Connection of Dect Portable Stations 152LAN Connection 219 215220 Starting the PBX 224Section System Outline Internet Protocol IP Telephone Features Ipcmpr Card FeaturesSystem Highlights System HighlightsNetworking Features Internet Protocol IP Related FeaturesExternal Device Support Other Useful FeaturesHospitality Features Built-in Small Call Centre FeaturesQueuing Feature Log-in/Log-outBasic Shelf Basic System ConstructionConstruction of the Basic Shelf Pure IP-PBX System Connection DiagramDPT Optional Equipment Optional EquipmentModel No Model Name Description DHLC8PAY8 GW4E General Description SpecificationsWeight when fully DimensionExtension Connection Cable MountedCharacteristics Type and Maximum Number of Slots System CapacityKX-TDE100 KX-TDE200 Cards Installed in Free Slots or Virtual Slots Maximum Optional Service CardsCard Type Maximum Number KX-TDE100 KX-TDE200 Maximum Trunks and Extensions Cards Mounted on Other Optional Service CardsCard Type Maximum Number Mounted on Type KX-TDE100 KX-TDE200Terminal Equipment Type KX-TDE100 KX-TDE200 Maximum Terminal EquipmentAPT IP-PT Load Figure Calculation Power Supply Unit SelectionEquipment Type Load Figure DHLC8 SLC8 SLC16 MSLC16Calculation Example KX-TDE200 PSU CapacityPSU Type Maximum Load Figure PSU-MSection Activation Key Installation Information about the Activation Keys Preinstalled Activation Keys in the DSP16/DSP64Activation Keys Type and Maximum Number of Activation KeysIP Softphone/IP PT Activation Key Installation ExampleModel No Activation Key Type Description Activation Key Card and Key Management SystemIP Trunk Activation Key File Installing the Activation Key File in the SD Memory CardFrom the Utility menu, select Refresh Activation Key Information about the Activation Keys Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Unpacking Installation of the PBXKX-TDE100 KX-TDE200 Inside View Names and LocationsOpening the Front Cover Opening/Closing the Front CoverClosing the Front Cover Accessories and User-supplied Items Installing/Replacing the Power Supply UnitSafety Instructions Accessories included Screws ×Installing the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Connect the frame of the PBX to earth Frame Earth ConnectionBackup Power Supply Duration Backup Battery ConnectionUser-supplied Items ExamplesConnecting Backup Batteries Installing Optional Service Cards Installing/Removing the Optional Service CardsBack Board Release Lever Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsBNC Mini Plug Attaching a Ferrite Core Attaching to an RJ45 ConnectorFor the Ipcmpr Card For T1/E1/PRI/IP-GW16/IP-EXT16 CardsFor a BRI Card For Extension Cards Attaching to an Amphenol ConnectorFastening an Amphenol Connector Amphenol Connector Pin Assignment Chart Wall Mounting KX-TDE200 Wall Wall Mounting KX-TDE100 30 mm Floor Standing KX-TDE200 Only TOP Front Installation Surge Protector InstallationOverview PBXInstallation of an Earth Rod Outside InstallationInstallation of the PBX Ipcmpr Card Information about the Main Processing CardMountable Cards BGM/MOHPin Assignments Signal Name Input I/Output O FunctionMNT Port/LAN Port 10BASE-T/100BASE-TX Indication Colour Description LED Indications2 DSP16 Card KX-TDE0110 and DSP64 Card KX-TDE0111 RMT Card KX-TDA0196 Virtual Cards Information about the Virtual CardsLED Information about the Physical Trunk CardsSignal Name Function Amphenol ConnectorCard Status 2 DID8 Card KX-TDA0182 LED Indications Switch Type Usage and Status Definition Switch Settings on LCOT8/LCOT16 cards3 CID/PAY8 Card KX-TDA0189 DIP4 CID8 Card KX-TDA0193 5 E&M8 Card KX-TDA0184 R1A T1ASGA SGBLED Indications 6 T1 Card KX-TDA0187 Switch SettingsRJ45 Connector for Extension Use RJ45 Connector for Trunk UseSignal Name Level Function Sync Maximum Cabling Distance of Extension ConnectionBNC TX 7 E1 Card KX-TDA0188BNC RX BNC coaxial Connector TX BNC coaxial Connector RX 8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288 RX2 TX1RX1 TX2Line Line LED PatternMaster Clock LED Pattern OFFMaximum Cabling Distance of S0 Bus Connection 9 PRI30 Card KX-TDA0290CE/CJ Switch Settings LED Indications Maximum Cabling Distance of Extension Connection 10 PRI23 Card KX-TDA0290 Pin Assignments Maximum Cabling Distance of Extension Connection IP-GW4E Card KX-TDA0484 RJ45 Connector 10BASE-T/100BASE-TXOnline AlarmData IP-GW16 Card KX-TDA0490 LED Indications CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144 Information about the Physical Extension CardsPowh RJ45 ConnectorPowl DHLC8 Card KX-TDA0170 D1A D2AD2B D1BLED Indications 3 DLC8 Card KX-TDA0171 Data port 1 Low 4 DLC16 Card KX-TDA0172 D1I D2ID2J D1J5 SLC8 Card KX-TDA0173 Pin Assignments EXT-CID Card KX-TDA0168 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175 Ring port Tip port 17-25 Reserved 42-50 IP-EXT16 Card KX-TDA0470 Online Information about the Other Physical Cards Accessories included none User-supplied not included none1 OPB3 Card KX-TDA0190 2 DPH4 Card KX-TDA0161 User-supplied not included Copper wireDP4 Pin Terminal BlockDP3 DP23 DPH2 Card KX-TDA0162 Pin Assignments Path Doorphone Call Path 4 EIO4 Card KX-TDA0164 Pin Assignments External Sensor Connection DiagramExternal Relay PBX OPB3ECHO16 Card KX-TDA0166 6 MSG4 Card KX-TDA0191 DSS Console Connection of ExtensionsBasic/High Density Parallel Connection of the Extensions Using a Modular T-AdaptorWith APT With DPTWith KX-T7600 Series DPT except KX-T7665 Using an EXtra Device PortDptslt With Other DPT except KX-T7560 and KX-T7565With KX-T7600 Series DPT except KX-T7600E Series Digital EXtra Device Port Digital XDP ConnectionBack View of DPTs To TEL To Main Unit With KX-T7600E Series DPT Connecting to a Slave DPT Connecting to a Master DPT First Party Call Control CTI Connection Connection of Dect Portable Stations RF SpecificationOverview Required Equipment and Maximum Number of CallsEquipment Distance Investigate the installation site Procedure OverviewPrepare for site survey Conduct the site surveyConnect the CS and PS to the PBX and test the operation Finish the site surveyMount the CS on the wall Site Planning Characteristics of Radio WavesUnderstanding Radio Waves Object Material Transmission Tendency CS Coverage Area Radio Signal Strength LevelsSite Survey Preparation CS installation plan Example Installing in a Room Separated by Interior WallsThings to take note Checking the CS ID Number Before Site SurveyAssigning the CS ID Number to the PS CS NoUsing the KX-TD7590 To enter letters DIP Switch Setting and Installing the CS Temporarily for Site SurveyOFF on KX-TDA0158CEKX-TDA0141CE/KX-TDA0142CE For users in the United KingdomTo survey other slots Testing the Radio Signal StrengthPS CH0 L12 Channel no Referring to the Stored Scan Data Using the KX-TD7590 Log NoClearing the Stored Scan Data On OFF OFF on After Site SurveyUsing a Csif Card Connecting a Cell Station to the PBXAccessories and User-supplied Items for the CS User-supplied not included RJ11 connectorD1C D2C D1B Using a DHLC/DLC CardD2B D1C D1D D2C D2D D2C D1G D1B D2GKX-TDA0141CE Connecting the CS For the KX-TDA0142CE User only Registering the PS Entering the PBX System Programming Mode Using a PTPS Registration System Lock Password /OK System Lock PasswordUsing the KX-TD7580 692 Setting the PIN for PBXChanging the Display Language of the PS PS Termination 691Handset PIN Testing the Operation Mounting the KX-TDA0158CE Wall MountingReference for Wall Mounting KX-TDA0158CE Install a screw here 83 mmMounting the KX-TDA0141CE/KX-TDA0142CE Reference for Wall Mounting KX-TDA0141CE/KX-TDA0142CE Install a screw here 71 mmConnection of 2.4 GHz Portable Stations Using the KX-TD7680 Using the KX-TD7684/KX-TD7694Using the KX-TD7690 Prepare the CS for site surveyFinish the site survey Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Interior Walls KX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142 KX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142 Scan Data No Site SurveyPS CS NO.1 LEVEL8 PS CS NO.1 LEVEL3 Scan Data No Deleting the Stored Scan Data 3 4 5 KX-TDA0152/KX-TDA0142 KX-TDA0151/KX-TDA0141 Connecting the CS Entering the System Programming Mode When the PS has already been registered to another PBX When the PS has not been registered yetSetting the System Lock Setting the PIN for PS Using the KX-TD7684/KX-TD7694 System Mounting the KX-TDA0151/KX-TDA0152 Hook the CS on the screw heads Reference for Wall Mounting KX-TDA0151/KX-TDA0152 Mounting the KX-TDA0141/KX-TDA0142 Reference for Wall Mounting KX-TDA0141/KX-TDA0142 Maximum Cabling Distance Installing the Doorphone KX-T30865Connection Installation Manual Connection of Peripherals Connection of PeripheralsPC via MNT Port Pin AssignmentsPager Signal Name Function Circuit TypePC/Printer via RS-232C Connection Charts Frame Ground FG Clear To Send CTS…inputLAN Connection Connection Chart for LAN ConnectionLAN Connection TX+ RX+Power Failure Connections Power Failure ConnectionsUsing Analogue Trunk Card and Extension Card RJ11 Connector Pin Assignments for Extension Card RJ11 Connector Pin Assignments for Analogue Trunk CardPFT Ports 1 Signal Name Function PFT Ports 3 and 4 for LCOT16 card only Signal Name FunctionSwitch Settings Using BRI CardRJ45 Connector Line 1 Pin Assignments RJ45 Connector Line 2 Pin Assignments Starting the PBX System Initialisation ProcedureStarting the PBX RUN Confirming the Trunk ConnectionStarting the PBX Section Guide for the KX-TDE Maintenance Console Overview KX-TDE Maintenance Console*1PC Connection PC ConnectionConnection via MNT Port of Ipcmpr Card Serial Interface ConnectionRD RXD SD TXD ER DTR DR DSR External Modem ConnectionPC Connection Installing and Starting the KX-TDE Maintenance Console Installation of the KX-TDE Maintenance ConsolePassword Security Installing the KX-TDE Maintenance ConsoleWhen country/area data do not match Installation of the KX-TDE Maintenance Console Section Troubleshooting Installation TroubleshootingProblem Probable Cause Solution Problem Probable Cause Solution Connection Cause SolutionTrunk is connected to the T2/R1 Operation Problem Probable Cause Solution Operation Using the Reset ButtonError Log Display Format Troubleshooting by Error LogDescription Description Troubleshooting Index Numerics MOH PSU Page For Future Reference
Related manuals
Manual 54 pages 18.65 Kb Manual 250 pages 16.25 Kb Manual 214 pages 62.01 Kb