Panasonic KX-TDE100 Maximum Trunks and Extensions, Cards Mounted on Other Optional Service Cards

Page 35

 

 

 

 

1.4 Specifications

 

 

 

 

 

Cards Mounted on Other Optional Service Cards

 

 

 

 

 

 

 

Card Type

Maximum Number

Mounted on

 

 

 

 

KX-TDE100

KX-TDE200

 

 

 

 

 

 

 

 

 

DSP16

1

1

 

 

 

 

 

DSP64

IPCMPR Card

 

 

 

 

 

 

 

 

 

RMT

1

1

 

 

 

 

 

 

 

CID/PAY8

12

16

LCOT8 Card/LCOT16 Card

 

 

 

CID8

 

 

 

 

 

 

 

 

 

 

EXT-CID

6

8

SLC8 Card

 

 

 

 

 

 

DPH4

4

4

 

 

 

 

 

 

 

DPH2

8

8

 

 

 

 

 

 

 

ECHO16

2*1

2*1

OPB3 Card

 

MSG4

4

4

 

 

 

 

 

 

 

EIO4

4

4

 

 

 

 

 

 

*1 Only 1 ECHO16 card can be mounted on each OPB3 card.

Maximum Trunks and Extensions

The PBX supports the following number of trunks and extensions.

 

 

Type

KX-TDE100

KX-TDE200

 

 

 

 

Total Number of Trunks

128

128

 

 

 

 

 

 

Trunk (Physical Trunk Card)

120

128

 

 

 

 

 

 

Trunk (Virtual Trunk Card)

32

32

 

 

 

 

 

Total Number of Extensions

256

256

 

 

 

 

 

 

Extension (Physical Extension Card)

160

256

 

 

 

 

 

 

Extension (Virtual Extension Card)

128

128

 

 

 

 

 

 

 

IP-PT and IP Softphone

64

64

 

 

 

 

 

 

 

SIP Extension

128

128

 

 

 

 

 

Note

For non-peer-to-peer calls via the DSP card, calls cannot be made or received when all of the card's resources are being used.

Installation Manual

35

Image 35
Contents Model No. KX-TDE100 Pure IP-PBXVirtual Trunk Cards Main Processing CardIpcmpr Option Cards Activation Key CardsOther Physical Cards KX-TDA0290CE/CJPhysical Extension Cards Incompatible Panasonic Proprietary Telephones Compatible Panasonic Proprietary TelephonesList of Abbreviations Important NoticeSecurity Requirements What is User Information?For All Telephone Equipment Safety RequirementsFor the PBX Installation Manual For users in New Zealand only For business users in the European UnionFor users in Germany only For users in Finland, Norway and Sweden onlyFor users in Taiwan only For users in Australia onlyTrademarks Structure of this ManualAbout the Other Manuals About the software version of your PBXInstallation Manual Precautions for Users in the United Kingdom Installation Manual Table of Contents Connection of Dect Portable Stations 152 Information about the Physical Extension Cards 116Information about the Other Physical Cards 132 Connection of Extensions 143Starting the PBX 224 215LAN Connection 219 220Section System Outline System Highlights Ipcmpr Card FeaturesInternet Protocol IP Telephone Features System HighlightsNetworking Features Internet Protocol IP Related FeaturesExternal Device Support Other Useful FeaturesLog-in/Log-out Built-in Small Call Centre FeaturesHospitality Features Queuing FeatureConstruction of the Basic Shelf Basic System ConstructionBasic Shelf Pure IP-PBX System Connection DiagramDPT DHLC8 Optional EquipmentOptional Equipment Model No Model Name DescriptionPAY8 GW4E General Description SpecificationsMounted DimensionWeight when fully Extension Connection CableCharacteristics KX-TDE100 KX-TDE200 System CapacityType and Maximum Number of Slots Card Type Maximum Number KX-TDE100 KX-TDE200 Maximum Optional Service CardsCards Installed in Free Slots or Virtual Slots Type KX-TDE100 KX-TDE200 Cards Mounted on Other Optional Service CardsMaximum Trunks and Extensions Card Type Maximum Number Mounted onAPT IP-PT Maximum Terminal EquipmentTerminal Equipment Type KX-TDE100 KX-TDE200 DHLC8 SLC8 SLC16 MSLC16 Power Supply Unit SelectionLoad Figure Calculation Equipment Type Load FigurePSU-M PSU CapacityCalculation Example KX-TDE200 PSU Type Maximum Load FigureSection Activation Key Installation Type and Maximum Number of Activation Keys Preinstalled Activation Keys in the DSP16/DSP64Information about the Activation Keys Activation KeysIP Softphone/IP PT Activation Key Installation ExampleIP Trunk Activation Key Card and Key Management SystemModel No Activation Key Type Description From the Utility menu, select Refresh Activation Key Installing the Activation Key File in the SD Memory CardActivation Key File Information about the Activation Keys Section Installation Installation Precautions Before InstallationBefore Installation Safety Installation InstructionsBefore Installation KX-TDE100 KX-TDE200 Installation of the PBXUnpacking Inside View Names and LocationsOpening the Front Cover Opening/Closing the Front CoverClosing the Front Cover Accessories included Screws × Installing/Replacing the Power Supply UnitAccessories and User-supplied Items Safety InstructionsInstalling the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Connect the frame of the PBX to earth Frame Earth ConnectionExamples Backup Battery ConnectionBackup Power Supply Duration User-supplied ItemsConnecting Backup Batteries Installing Optional Service Cards Installing/Removing the Optional Service CardsBack Board Release Lever Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards BNC Types of ConnectorsConnector Type Pin Number Used for Mini Plug For T1/E1/PRI/IP-GW16/IP-EXT16 Cards Attaching to an RJ45 ConnectorAttaching a Ferrite Core For the Ipcmpr CardFor a BRI Card For Extension Cards Attaching to an Amphenol ConnectorFastening an Amphenol Connector Amphenol Connector Pin Assignment Chart Wall Mounting KX-TDE200 Wall Wall Mounting KX-TDE100 30 mm Floor Standing KX-TDE200 Only TOP Front PBX Surge Protector InstallationInstallation OverviewInstallation of an Earth Rod Outside InstallationInstallation of the PBX BGM/MOH Information about the Main Processing CardIpcmpr Card Mountable CardsMNT Port/LAN Port 10BASE-T/100BASE-TX Signal Name Input I/Output O FunctionPin Assignments Indication Colour Description LED Indications2 DSP16 Card KX-TDE0110 and DSP64 Card KX-TDE0111 RMT Card KX-TDA0196 Virtual Cards Information about the Virtual CardsLED Information about the Physical Trunk CardsCard Status Amphenol ConnectorSignal Name Function 2 DID8 Card KX-TDA0182 LED Indications DIP Switch Settings on LCOT8/LCOT16 cardsSwitch Type Usage and Status Definition 3 CID/PAY8 Card KX-TDA01894 CID8 Card KX-TDA0193 5 E&M8 Card KX-TDA0184 SGB T1AR1A SGALED Indications 6 T1 Card KX-TDA0187 Switch SettingsSignal Name Level Function RJ45 Connector for Trunk UseRJ45 Connector for Extension Use Sync Maximum Cabling Distance of Extension ConnectionBNC RX 7 E1 Card KX-TDA0188BNC TX BNC coaxial Connector TX BNC coaxial Connector RX 8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288 TX2 TX1RX2 RX1OFF Line LED PatternLine Master Clock LED PatternMaximum Cabling Distance of S0 Bus Connection 9 PRI30 Card KX-TDA0290CE/CJ Switch Settings LED Indications Maximum Cabling Distance of Extension Connection 10 PRI23 Card KX-TDA0290 Pin Assignments Maximum Cabling Distance of Extension Connection IP-GW4E Card KX-TDA0484 RJ45 Connector 10BASE-T/100BASE-TXData AlarmOnline IP-GW16 Card KX-TDA0490 LED Indications CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144 Information about the Physical Extension CardsPowl RJ45 ConnectorPowh DHLC8 Card KX-TDA0170 D1B D2AD1A D2BLED Indications 3 DLC8 Card KX-TDA0171 Data port 1 Low 4 DLC16 Card KX-TDA0172 D1J D2ID1I D2J5 SLC8 Card KX-TDA0173 Pin Assignments EXT-CID Card KX-TDA0168 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175 Ring port Tip port 17-25 Reserved 42-50 IP-EXT16 Card KX-TDA0470 Online 1 OPB3 Card KX-TDA0190 Accessories included none User-supplied not included noneInformation about the Other Physical Cards 2 DPH4 Card KX-TDA0161 User-supplied not included Copper wireDP2 Pin Terminal BlockDP4 DP33 DPH2 Card KX-TDA0162 Pin Assignments Path Doorphone Call Path 4 EIO4 Card KX-TDA0164 Pin Assignments PBX OPB3 Connection DiagramExternal Sensor External RelayECHO16 Card KX-TDA0166 6 MSG4 Card KX-TDA0191 Basic/High Density Connection of ExtensionsDSS Console With DPT Using a Modular T-AdaptorParallel Connection of the Extensions With APTWith Other DPT except KX-T7560 and KX-T7565 Using an EXtra Device PortWith KX-T7600 Series DPT except KX-T7665 DptsltBack View of DPTs Digital EXtra Device Port Digital XDP ConnectionWith KX-T7600 Series DPT except KX-T7600E Series To TEL To Main Unit With KX-T7600E Series DPT Connecting to a Slave DPT Connecting to a Master DPT First Party Call Control CTI Connection Required Equipment and Maximum Number of Calls RF SpecificationConnection of Dect Portable Stations OverviewEquipment Distance Conduct the site survey Procedure OverviewInvestigate the installation site Prepare for site surveyMount the CS on the wall Finish the site surveyConnect the CS and PS to the PBX and test the operation Understanding Radio Waves Characteristics of Radio WavesSite Planning Object Material Transmission Tendency Site Survey Preparation Radio Signal Strength LevelsCS Coverage Area Things to take note Example Installing in a Room Separated by Interior WallsCS installation plan CS No Before Site SurveyChecking the CS ID Number Assigning the CS ID Number to the PSUsing the KX-TD7590 To enter letters DIP Switch Setting and Installing the CS Temporarily for Site SurveyOFF on KX-TDA0158CEKX-TDA0141CE/KX-TDA0142CE For users in the United KingdomTo survey other slots Testing the Radio Signal StrengthPS CH0 L12 Channel no Clearing the Stored Scan Data Using the KX-TD7590 Log NoReferring to the Stored Scan Data On OFF OFF on After Site SurveyUser-supplied not included RJ11 connector Connecting a Cell Station to the PBXUsing a Csif Card Accessories and User-supplied Items for the CSD2C D1G D1B D2G Using a DHLC/DLC CardD1C D2C D1B D2B D1C D1D D2C D2DKX-TDA0141CE Connecting the CS For the KX-TDA0142CE User only PS Registration Entering the PBX System Programming Mode Using a PTRegistering the PS Using the KX-TD7580 System Lock PasswordSystem Lock Password /OK Changing the Display Language of the PS Setting the PIN for PBX692 Handset PIN 691PS Termination Testing the Operation Mounting the KX-TDA0158CE Wall MountingReference for Wall Mounting KX-TDA0158CE Install a screw here 83 mmMounting the KX-TDA0141CE/KX-TDA0142CE Reference for Wall Mounting KX-TDA0141CE/KX-TDA0142CE Install a screw here 71 mmConnection of 2.4 GHz Portable Stations Prepare the CS for site survey Using the KX-TD7684/KX-TD7694Using the KX-TD7680 Using the KX-TD7690Finish the site survey Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Interior Walls KX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142 KX-TDA0151/KX-TDA0152 KX-TDA0141/KX-TDA0142 Scan Data No Site SurveyPS CS NO.1 LEVEL8 PS CS NO.1 LEVEL3 Scan Data No Deleting the Stored Scan Data 3 4 5 KX-TDA0152/KX-TDA0142 KX-TDA0151/KX-TDA0141 Connecting the CS Entering the System Programming Mode When the PS has already been registered to another PBX When the PS has not been registered yetSetting the System Lock Setting the PIN for PS Using the KX-TD7684/KX-TD7694 System Mounting the KX-TDA0151/KX-TDA0152 Hook the CS on the screw heads Reference for Wall Mounting KX-TDA0151/KX-TDA0152 Mounting the KX-TDA0141/KX-TDA0142 Reference for Wall Mounting KX-TDA0141/KX-TDA0142 Maximum Cabling Distance Installing the Doorphone KX-T30865Connection Installation Manual Pin Assignments Connection of PeripheralsConnection of Peripherals PC via MNT PortPC/Printer via RS-232C Signal Name Function Circuit TypePager Connection Charts Frame Ground FG Clear To Send CTS…inputTX+ RX+ Connection Chart for LAN ConnectionLAN Connection LAN ConnectionUsing Analogue Trunk Card and Extension Card Power Failure ConnectionsPower Failure Connections PFT Ports 3 and 4 for LCOT16 card only Signal Name Function RJ11 Connector Pin Assignments for Analogue Trunk CardRJ11 Connector Pin Assignments for Extension Card PFT Ports 1 Signal Name FunctionRJ45 Connector Line 1 Pin Assignments Using BRI CardSwitch Settings RJ45 Connector Line 2 Pin Assignments Starting the PBX System Initialisation ProcedureStarting the PBX RUN Confirming the Trunk ConnectionStarting the PBX Section Guide for the KX-TDE Maintenance Console Overview KX-TDE Maintenance Console*1Serial Interface Connection PC ConnectionPC Connection Connection via MNT Port of Ipcmpr CardRD RXD SD TXD ER DTR DR DSR External Modem ConnectionPC Connection Installing the KX-TDE Maintenance Console Installation of the KX-TDE Maintenance ConsoleInstalling and Starting the KX-TDE Maintenance Console Password SecurityWhen country/area data do not match Installation of the KX-TDE Maintenance Console Section Troubleshooting Installation TroubleshootingProblem Probable Cause Solution Problem Probable Cause Solution Connection Cause SolutionTrunk is connected to the T2/R1 Operation Problem Probable Cause Solution Operation Using the Reset ButtonDescription Troubleshooting by Error LogError Log Display Format Description Troubleshooting Index Numerics MOH PSU Page For Future Reference
Related manuals