Uniden GRANT owner manual Specifications, General

Page 10

SPECIFICATIONS

GENERAL

F .C.C. Type Number

Channels

Frequency Range

Frequency Control

Frequency Tolerance

Frequency Stability

Operating Temperature Range Microphone

Input Voltage

Current Drain

Cabinet Dimensions

Weight

Antenna Connector

Semiconductors

Meter

Indicators

TRANSMITTER

Power Output

Modulation

Intermodulation Distortion

SSB Carrier Suppression Unwanted Sideband

1005002

40AM, 40LSB, 40USB

26.965 to 27.405 MHz

Phase Locked Loop(PLL) synthesized circuitry. 0.005%

0.001%

-20°C to +50°C

Plug-in type; dynamic with push-to-talk switch and coiled cord.

13.8V DC nominal, 15.9V max., 11.7V min. (positive or negative ground).

Transmit: AM full mod., 3A maximum.

SSB, 12 watts PEP output, 3A maximum.

Receiver: squelched; 0.5A, maximum audio output 1A.

7-7/8"(W) x 2-3/8"(H) x 9-1/4"(D)

5pounds UHF, SO-239

44 transistors, 3 field effect transistors, 6 inte-

grated circuits, 62 diodes and 3 light emitting diodes.

Illuminated; indicates relative RF power output and modulation on Transmit, received signal strength.

LED display; channel, emergency channel and TX/RX.

AM,4 watts

SSB, 12 watts, P.E.P.

High and Iow level Class B, Amplitude Modula- tion.

SSB: 3rd and 5th order, more than -25 dB. 7th and 9th order, more than -35 dB.

More than -45 dB.

More than -45 dB.

-9-

Image 10
Contents Uniden@ Introduction Elimination of LicensingMobile Station Antenna Mobile Station InstallationPower Cord Connection Negative Ground System Ground InfrmationPower Cord Connection Positive Ground System Base Station OperationOperating Procedure To ReceiveControls and Their Functions @ @ J@ @ @ @ MODPosition Meter indicates averagepercentage of modulation Radio Back Panel Connectors @ @Page Specifications GeneralReceiver Servicing Your Transceiver Operator Troubleshooting Page Page Circuit For GrantBlock Diagram for Grant Uniden